Plan Review Details - Permit 13080387
Plan Review Stops For Permit 13080387
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-09-27 Cont ID  
Sent By HILL Date 2013-09-27 Time 06:31 Rev Time 0.00
Received By jwitmer Date 2013-09-27 Time 06:09 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-08-17 Cont ID  
Sent By dkittred Date 2013-08-17 Time 12:00 Rev Time 0.00
Received By jwitmer Date 2013-08-17 Time 11:04 Sent To  
Notes
2013-08-17 11:57:20BUILDING PLAN REVIEW
 PERMIT: 13080387
 ADD: 2414 FORIDA AVE
 CONT: TBD
 TEL: (561)318-5243 MICHAEL NELSON
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: AUGUST 17/ 2013
 ACTION: DENIED
  
 1) THIS IS THE SECOND PHASE OF PERMITING, PLEASE SHOW
 COMPLIANCE WITH THE PROVISO FROM PERMIT 12120673 AND
 THE CURENT PERMIT APPLICATION 13080387 THE COMBINED
 DOLLAR VALUE OF $15,000.00 .
 PROVISO FROM 12120673, BUILDING PROVISO:
 2010 FL ACCESSIBILITY CODE 202.4 & ADVISORY. PROVIDE
 INFORMATION REGARDING THE OTHER ACCESSBILE FEATURES &
 PROPOSED .
  
 PLEASE NOTE THE COMBINED VALUE OF THE 2 PERMITS IS
 $15,000.00 PLEASE PROVIDE COMPLIANCE WITH SHOWING
 $3,000 DOLLARE IN ACCESSIBLE UPGRADES.
 2010 FLORIDA ACCESSIBLITY CODE.
 202.4.1 DISPROPORTIONATE COST.
 ALTERATIONS MADE TO PROVIDE AN ACCESSIBLE PATH OF
 TRAVEL TO THE ALTERED AREA WILL BE DEEMED
 DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN THE
 COST EXCEEDS 20% OF THE COST OF THE ALTERATION TO THE
 PRIMARY FUNCTION AREA. COSTS THAT MAY BE COUNTED AS
 EXPENDITURES REQUIRED TO PROVIDE AN ACCESSIBLE PATH OF
 TRAVEL MAY INCLUDE: (I) COSTS ASSOCIATED WITH PROVIDING
 AN ACCESSIBLE ENTRANCE AND AN ACCESSIBLE ROUTE TO THE
 ALTERED AREA; (II) COSTS ASSOCIATED WITH MAKING
 RESTROOMS ACCESSIBLE, SUCH AS INSTALLING GRAB BARS,
 ENLARGING TOILET STALLS, INSULATING PIPES, OR
 INSTALLING ACCESSIBLE FAUCET CONTROLS; (III) COSTS
 ASSOCIATED WITH PROVIDING ACCESSIBLE TELEPHONES, SUCH
 AS RELOCATING THE TELEPHONE TO AN ACCESSIBLE HEIGHT,
 INSTALLING AMPLIFICATION DEVICES, OR INSTALLING A TEXT
 TELEPHONE (TTY); (IV) COSTS ASSOCIATED WITH RELOCATING
 AN INACCESSIBLE DRINKING FOUNTAIN.
  
 202.4.2 ACCESSIBLE FEATURES IN THE EVENT OF
 DISPROPORTIONALITY.
 WHEN THE COST OF ALTERATIONS NECESSARY TO MAKE THE PATH
 OF TRAVEL TO THE ALTERED AREA FULLY ACCESSIBLE IS
 DISPROPORTIONATE TO THE COST OF THE OVERALL ALTERATION,
 THE PATH OF TRAVEL SHALL BE MADE ACCESSIBLE TO THE
 EXTENT THAT IT CAN BE MADE ACCESSIBLE WITHOUT INCURRING
 DISPROPORTIONATE COSTS. IN CHOOSING WHICH ACCESSIBLE
 ELEMENTS TO PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE
 ELEMENTS THAT WILL PROVIDE THE GREATEST ACCESS, IN THE
 FOLLOWING ORDER: (I) AN ACCESSIBLE ENTRANCE; (II) AN
 ACCESSIBLE ROUTE TO THE ALTERED AREA; (III) AT LEAST
 ONE ACCESSIBLE RESTROOM FOR EACH SEX OR A SINGLE UNISEX
 RESTROOM; (IV) ACCESSIBLE TELEPHONES; (V) ACCESSIBLE
 DRINKING FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL
 ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND
 ALARMS.
  
 202.4.3 SERIES OF SMALLER ALTERATIONS.
 THE OBLIGATION TO PROVIDE AN ACCESSIBLE PATH OF TRAVEL
 MAY NOT BE EVADED BY PERFORMING A SERIES OF SMALL
 ALTERATIONS TO THE AREA SERVED BY A SINGLE PATH OF
 TRAVEL IF THOSE ALTERATIONS COULD HAVE BEEN PERFORMED
 AS A SINGLE UNDERTAKING.
  
 202.4.3.1
 IF AN AREA CONTAINING A PRIMARY FUNCTION HAS BEEN
 ALTERED WITHOUT PROVIDING AN ACCESSIBLE PATH OF TRAVEL
 TO THAT AREA, AND SUBSEQUENT ALTERATIONS OF THAT AREA,
 OR A DIFFERENT AREA ON THE SAME PATH OF TRAVEL, ARE
 UNDERTAKEN WITHIN THREE YEARS OF THE ORIGINAL
 ALTERATION, THE TOTAL COST OF ALTERATIONS TO THE
 PRIMARY FUNCTION AREAS ON THAT PATH OF TRAVEL DURING
 THE PRECEDING THREE YEAR PERIOD SHALL BE CONSIDERED IN
 DETERMINING WHETHER THE COST OF MAKING THAT PATH OF
 TRAVEL ACCESSIBLE IS DISPROPORTIONATE.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2013-10-01 Cont ID  
Sent By HARVEY Date 2013-10-01 Time 08:57 Rev Time 0.00
Received By dharvey Date 2013-10-01 Time 08:24 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2013-09-04 Cont ID  
Sent By dharvey Date 2013-09-04 Time 18:41 Rev Time 0.00
Received By dharvey Date 2013-09-04 Time 18:41 Sent To  
Notes
2013-09-04 18:45:28FIRST REVIEW - 9-4-13
  
 1. SHOW CIRCUITS ON ELECTRICAL DRAWING FLOOR PLAN
 2. IF THERE ARE EXISTING LIGHT FIXTURES, PLEASE
 INDICATE ON DRAWINGS. "NO CHANGES"
 3. PROVIDE A COPY OF PANEL SCHEDULE ON DRAWINGS
 VB

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2013-10-02 Cont ID  
Sent By LPHILMOR Date 2013-10-02 Time 14:56 Rev Time 0.00
Received By lphilmor Date 2013-10-02 Time 14:56 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2013-08-21 Cont ID  
Sent By lphilmor Date 2013-08-21 Time 15:39 Rev Time 0.00
Received By lphilmor Date 2013-08-21 Time 15:39 Sent To  
Notes
2013-08-21 15:45:052414 FLORIDA AVE
 PERMIT # 13080387
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 1. PLANS INDICATE MIXED USE NON-SEPARATED. PLEASE
 INDICATE THE ADDITIONAL OCCUPANCY TYPE BEING
 CONSIDERED.
 2. DEAD END CORRIDOR EXCEEDS 20 FT.
  
 LAUREN PHILMORE
 FIRE INSPECTOR II / INVESTIGATOR I
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 804-4783
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status   Date 2013-10-02 Cont ID  
Sent By lphilmor Date 2013-10-02 Time 14:56 Rev Time 0.00
Received By lphilmor Date 2013-09-18 Time 18:47 Sent To  
Notes
2013-09-19 18:50:06B15

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-09-04 Cont ID  
Sent By dharvey Date 2013-09-04 Time 18:45 Rev Time 0.00
Received By dharvey Date 2013-09-04 Time 18:45 Sent To  
Notes
2013-08-13 13:01:36INCOMING SENT TO B09 . JW

Review Stop Z ZONING
Rev No 1 Status P Date 2013-08-16 Cont ID  
Sent By dkittred Date 2013-08-16 Time 14:08 Rev Time 0.00
Received By dkittred Date 2013-08-16 Time 13:47 Sent To  
Notes
2013-08-16 14:11:52PLANNING & ZONING NOTES:
  
 8/16/2013
  
 INTERIOR RENNOVATION ONLY. VALUE OF IMPROVEMENTS TO DO
 TRIGGER ANY ADDITIONAL ZONING REQUIREMENTS. -DK