Plan Review Details - Permit 13080222
Plan Review Stops For Permit 13080222
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2013-08-07 Cont ID  
Sent By jwitmer Date 2013-08-07 Time 08:31 Rev Time 0.00
Received By jwitmer Date 2013-08-07 Time 07:31 Sent To  
Notes
2013-08-07 07:56:13BUILDING PLAN REVIEW
 PERMIT: 13080222
 ADD: 1200 S FLAGLER # 1403
 CONT: KDN CONSTRUCTION
 TEL: (561)214-3080
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. AUGUST 7/2013
 ACTION: PROVISO
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
  
 1A) FBC-B 2010 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
 1B) FBC-B 2010 603.2 EXCEPTION (1) TILE FLOORING
 FLOOR INSULATION PLACED BETWEEN TWO LAYERS OF
 NONCOMBUSTIBLE MATERIALS WITHOUT AN INTERVENING
 AIRSPACE SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX
 OF NOT MORE THAN 100.
  
 FBC-B 2010
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2013-08-07 Cont ID  
Sent By dharvey Date 2013-08-07 Time 16:52 Rev Time 0.00
Received By dharvey Date 2013-08-07 Time 16:45 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-08-12 Cont ID  
Sent By lwagner Date 2013-08-12 Time 15:02 Rev Time 0.00
Received By lwagner Date 2013-08-06 Time 15:24 Sent To  
Notes
2013-08-06 15:26:35INCOMING SENT TO B-27. JW

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2013-08-07 Cont ID  
Sent By jwitmer Date 2013-08-07 Time 07:56 Rev Time 0.00
Received By jwitmer Date 2013-08-07 Time 07:56 Sent To  
Notes
2013-08-07 07:57:36NO MECHANICAL SHOWN ON PLAN, NO WALL CHANGES THAT WOULD
 EFFECT BALANCING AND RETURN AIR. JW

Review Stop P PLUMBING
Rev No 1 Status P Date 2013-08-12 Cont ID  
Sent By lwagner Date 2013-08-12 Time 15:02 Rev Time 0.00
Received By lwagner Date 2013-08-12 Time 14:59 Sent To  
Notes
***NONE***