| Plan Review Stops For Permit 13080083 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2013-08-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-08-28 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-08-28 |
Time |
09:29 |
Sent To |
|
|
| Notes |
| 2013-08-28 09:43:03 | BUILDING REVIEW APPROVED WITH PROVISO (PROVIDE | | | INFORMATION PRIOR TO INSPECTION TO AVOID CONFLICTS OR | | | DELAYS): | | | | | | 1- PROVIDE PRODUCT APPROVALS FOR: | | | A) SHINGLES. NOA 11-1122.04 SUBMITTED WAS SUPERSEDED BY | | | MIAMI-DADE. | | | | | | B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON | | | PLANS. | | | | | | 2- ENGINEER OF RECORD TO REVIEW ALL PRODUCT APPROVALS. | | | | | | 3- A) REVISE TENANT SEPARATION WALL SECTION. NEED | | | TENANT SEPARATION AT FLOOR CEILING AREA. NEED TO | | | SPECIFY ASSEMBLY TESTED PER ASTM E 119 OR UL 263 AS | | | REQUIRED BY SEC. R302.3 OF 2010 FBC-RESIDENTIAL. AND, | | | COORDINATE THIS INFORMATION WITH THE EXISTING TYPICAL | | | WALL SECTION SUBMITTED. | | | ***NOTE; ASSEMBLY TO INCLUDE INSULATION AS SHOWN ON | | | PLANS.. | | | | | | B) PROVIDE SPECIFICATIONS FOR THE FIRE RATING OF THE | | | SUPPORTING CONSTRUCTION AS REQUIRED BY SEC. R302.3.1. | | | | | | C) PROVIDE SPECIFICATIONS FOR THE RATED PENETRATIONS AS | | | REQUIRED BY SEC. R302.4. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-08-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-08-07 |
Time |
17:35 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-08-07 |
Time |
17:34 |
Sent To |
|
|
| Notes |
| 2013-08-07 17:41:46 | RESIDENTIAL (R3) RENOVATION, BUILDING REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- CLARIFY SCOPE OF WORK. PLANS SUBMITTED DON'T SPECIFY | | | SHINGLES RE-ROOF BUT THERE WERE SHINGLES AND | | | UNDERLAYMENT PRODUCT APPROVALS SUBMITTED. REVISE AS | | | REQUIRED. SEC. 107.2.1 CITY AMENDMENTS TO FBC. | | | | | | 2- PROVIDE PRODUCT APPROVALS (2 COPIES) AS REQUIRED BY | | | DCA RULE 9N-3 FOR: | | | A) SHINGLES (IF DOING RE-ROOF. SEE COMMENT #1 ABOVE.). | | | NOA 11-1122.04 SUBMITTED WAS SUPERSEDED BY MIAMI-DADE. | | | NEED CURRENT NOA. | | | | | | B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON | | | PLANS. | | | | | | C) WINDOW MULLIONS AS SHOWN ON PLANS. | | | | | | 3- ENGINEER OF RECORD TO REVIEW PRODUCT APPROVALS. SEC. | | | 107.3.4.1 CITY AMENDMENTS. | | | | | | 4- A) REVISE TENANT SEPARATION WALL SECTION. NEED | | | TENANT SEPARATION AT FLOOR CEILING AREA. NEED TO | | | SPECIFY ASSEMBLY TESTED PER ASTM E 119 OR UL 263 AS | | | REQUIRED BY SEC. R302.3 OF 2010 FBC-RESIDENTIAL. AND, | | | COORDINATE THIS INFORMATION WITH THE EXISTING TYPICAL | | | WALL SECTION SUBMITTED. | | | ***NOTE: ASSEMBLY TO INCLUDE INSULATION AS SHOWN ON | | | PLANS. | | | | | | B) PROVIDE SPECIFICATIONS FOR THE FIRE RATING OF THE | | | SUPPORTING CONSTRUCTION AS REQUIRED BY SEC. R302.3.1. | | | | | | C) PROVIDE SPECIFICATIONS FOR THE RATED PENETRATIONS AS | | | REQUIRED BY SEC. R302.4. | | | | | | 5- BEDROOM WINDOWS: CLEARLY IDENTIFY ON PLANS TYPE AND | | | SIZE OF EXISTING WINDOWS TO VERIFY COMPLIANCE WITH THE | | | EGRESS REQUIREMENTS OF SEC. 601.2 OF 2010 FBC-EXISTING | | | BUILDING. | | | | | | 6- SPECIFY HOW PROVIDING HEAT AS REQUIRED BY SEC. | | | R303.8. | | | | | | 7- PROVIDE ENERGY CALCULATIONS. SEC. 103.2 OF 2010 | | | FBC-ENERGY CONSERVATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2013-09-10 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-09-09 |
Time |
06:53 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-09-09 |
Time |
06:24 |
Sent To |
|
|
| Notes |
| 2013-09-09 06:53:15 | MIKE WITH HURRICANE PROVIDED REVISIONS SUITABLE FOR | | | ISSUANCE. PLANS RE-REVIEWED AND SIGNED OFF. DH 9/10/13 | | | | | | | | | | | | LOAD CALULATION AND RISER DO NOT AGREE - ONE SHOWS 400A | | | AND ONE SHOWS 200A | | | PROVIDE INTERSYSTEM BONDING POINT PER 250.94 | | | PROVIDE 3 WAY SWITCH AT STEPS | | | NO CLOSETS ARE SHOWN IN THE BEDROOMS. PLEASE LOCATE | | | SMOKE ALARMS IN ACCORDANCE WITH MANUFACTURERS | | | SPECIFICATIONS FOR BEST COVERAGE AND EARLIEST DETECTION | | | PROVIDE CALCULATION SHOWING 22K AIC GEAR AND CLARIFY | | | RATING OF THE METER CAN. WHAT IS DOWNSTREAM LETTHROUGH? | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2013-09-03 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-09-03 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-09-03 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2013-09-03 16:30:04 | SERVICE CALCULATION IS NOT PER NEC 220. UNITS HAVE A | | | 125A SERVICE AND OVERALL LOAD CALC SHOWS 57.5 A. NO | | | HEAT IS PROVIDED. | | | PROVIDE DETAILED CUT SHEET ON A/C UNITS SHOWING ACTUAL | | | LOAD AND CIRCUIT REQUIRED PER THE LISTING. 110.3, 430, | | | 440 | | | WIRE SIZES DO NOT MATCH OVERCURRENT PROTECTION - | | | 310.15, 310.15, 240.6 | | | PROVIDE AIC CALCULATIONS AND/OR VALUES FOR METER CENTER | | | AND ELECTRIC LOAD CENTERS. 110. | | | PROVIDE ARC FLASH WARNINGS PER 110.26 | | | PLANS NOT COMPLETE, ADDITIONAL ITEMS MAY BE NOTED BASED | | | ON RESPONSES. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2013-08-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-08-13 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-08-13 |
Time |
07:25 |
Sent To |
|
|
| Notes |
| 2013-08-13 08:31:56 | 2010 FBC / 2008 NEC | | | TWO FAMILY DWELLING | | | | | | DENIED BY ELECTRICAL | | | | | | 1) NEC 230.2 REQUIRES ONE SERVICE FOR THIS BUILDING AND | | | THE PLANS SHOW TWO SEPARATE SERVICES. PLEASE REVISE THE | | | RISER DIAGRAM. | | | | | | 2) PROVIDE A HOUSE LOAD CALCULATION IN COMPLIANCE WITH | | | NEC 220.84 (B) AND 220.85 TO DETERMINE THE SERVICE | | | LOAD. THIS IS IN ADDITION TO THE DWELLING UNIT LOADS | | | CALCULATED IN COMPLIANCE WITH NEC 220.40. | | | | | | 3) THE CALCULATIONS THAT WERE SUBMITTED HAVE AN ERROR | | | IN THE ADDITION FOR THE TOTAL LOAD. IT SHOULD BE 26,000 | | | WATTS. THIS IS EQUAL TO 108 AMPS. BASED ON YOUR | | | CALCULATIONS THE SPECIFIED PANEL SIZE OF 100 AMPS IS | | | TOO SMALL PER NEC 220.40. PLEASE CORRECT. | | | | | | 4) THERE IS NO WATER HEATER INDICATED ON THE PLANS OR | | | WATER HEATER CIRCUIT SHOWN IN THE PANEL SCHEDULE FOR | | | THE SECOND FLOOR UNIT. IF THE INTENT IS FOR BOTH UNITS | | | TO SHARE ONE WATER HEATER IT SHOULD BE LOCATED IN A | | | COMMON AREA AND FEED FROM A METER THAT SERVICES THE | | | COMMON AREAS. OTHERWISE, THE OCCUPANT IN UNIT ONE IS | | | PAYING TO HEAT THE WATER FOR UNIT TWO. THIS APPEARS TO | | | BE IN VIOLATION OF FBCR P2801.1 PLEASE CLARIFY. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-09-09 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-09-09 |
Time |
06:54 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-09-05 |
Time |
07:46 |
Sent To |
|
|
| Notes |
| 2013-09-09 06:54:07 | PLACED IN DENIED FILE UNDER "H" DH | | 2013-09-06 07:47:05 | SENT TO D HARVEY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-09-04 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-09-04 |
Time |
07:03 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-08-16 |
Time |
16:50 |
Sent To |
|
|
| Notes |
| 2013-09-04 07:04:22 | PLACED IN DENIED UNDER "H" | | 2013-08-16 16:50:30 | INCOMING SENT TO R24 BOX. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-08-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-08-13 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-08-02 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2013-08-13 15:16:53 | ZONING REVIEW DONE ON 8/13/13. JG. | | 2013-08-05 13:45:39 | **** E X P E D I T E D **** | | | | | | R21 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2013-08-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-08-28 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-08-28 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2013-08-28 10:05:28 | PLUMBING REVIEW APPROVED WITH PROVISO: | | | | | | 1- PROVIDE CLEAR AND CORRECT PLUMBING RISER DIAGRAM | | | THAT MATCHES PLANS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2013-08-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-08-07 |
Time |
18:09 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-08-07 |
Time |
18:09 |
Sent To |
|
|
| Notes |
| 2013-08-07 18:10:03 | RESIDENTIAL (R3) RENOVATION, PLUMBING REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- PLUMBING RISER DIAGRAM SUBMITTED DOESN'T MATCH | | | FIXTURE LAYOUT SHOWING ON THE FLOOR PLAN. REVISE AS | | | REQUIRED. SEC. 107.2.1 CITY AMENDMENTS TO FBC. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2013-08-27 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2013-08-27 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2013-08-27 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2013-08-27 11:49:05 | PROVISO: LA DRAWINGS SHALL BE SUBMITTED BEFORE CO. | | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | | APONTE AT 561-822-1439. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2013-08-13 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2013-08-13 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2013-08-13 |
Time |
11:56 |
Sent To |
|
|
| Notes |
| 2013-08-13 11:59:45 | 1. SURVEY INDICATES ONE ADDITIONAL EXTERIOR STAIR. | | | DRAWINGS DO NOT SHOW OR INDICATE PROPOSED DEMOLITION. | | | 2. LANDSCAPE DRAWINGS SHALL BE SUBMITTED. | | | 3. TWO UNITS ALLOWED ON 422 10 STREET, 1 UNIT ALLOWED | | | ON 420 10 STREET, AND 1 UNIT ALLOWED ON 418 10TH | | | STREET. | | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | | APONTE AT 561-822-1439. |
|
|