| Plan Review Stops For Permit 13080082 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2013-09-09 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-09-09 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-09-09 |
Time |
17:05 |
Sent To |
|
|
| Notes |
| 2013-09-09 17:10:53 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | | | 1- SHEET #2: REVISE ALL ROOF SHEATHING NAILING | | | SPECIFICATIONS. SPECIFY 8D RING SHANK NAILS MIN. | | | ENGINEER TO PROVIDE COMPLETE ENGINEERING ANALYSIS FOR | | | ANY OTHER ALTERNATIVE NAILS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2013-08-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-08-27 |
Time |
18:39 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-08-27 |
Time |
18:39 |
Sent To |
|
|
| Notes |
| 2013-08-27 18:40:39 | RESIDENTIAL (R3) ADDITION/ALTERATION, SECOND BUILDING | | | REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- PROVIDE ENERGY CALCULATIONS. SEC. 103.2 OF 2010 | | | FBC-ENERGY CONSERVATION. (NO ADDRESSED). | | | ***AND COORDINATE WITH FLOOR PLANS. | | | | | | 2- PROVIDE COMPLETE WINDOW/DOOR FRAMING DETAILS. SEC. | | | 107.2.1 CITY AMENDMENTS TO FBC. | | | ***HEADER FRAMING DETAIL IS MISSING STUDS. DETAIL ON | | | SHEET NO 2 IS ONLY SHOWING ONE STUD SUPPORTING THE | | | HEADER. REVISE AS REQUIRED. | | | | | | 3- SHEET #2: | | | A) REVISE ALL ROOF SHEATHING NAILING SPECIFICATIONS. | | | NEED TO USE 8D RING SHANK NAILS MIN. (ALL OTHER NAILS | | | SPECIFIED ON PLYWOOD NAILING REQUIREMENTS ARE NOT | | | ALLOWED). AND ROOF ZONE #3 NAIL SPACING IS 4"O.C. SEE | | | SEC. R803.2.3.1 OF 2010 FBC-RESIDENTIAL. | | | | | | B) ROOF DIAGRAM IS MISSING ROOF ZONE #3 ON THE HIP | | | ROOF. SEE FIGURE R301.2(7) AND REVISE AS REQUIRED. | | | | | | 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | DCA RULE 9N-3 FOR: | | | A) ROOF SHINGLES. NOA 11-1122.04 SUBMITTED WAS | | | SUPERSEDED BY MIAMI-DADE. NEED TO PROVIDE CURRENT NOA. | | | (NOT ADDRESSED). | | | | | | B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON | | | PLANS, SECTIONS, DETAILS. (NOT ADDRESSED). | | | | | | 5- ENGINEER OF RECORD TO REVIEW AND APPROVED ABOVE | | | PRODUCT APPROVALS. SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH ITEM | | | TO EXPEDITE THE REVIEW PROCESS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-08-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-08-05 |
Time |
18:07 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-08-05 |
Time |
17:42 |
Sent To |
|
|
| Notes |
| 2013-08-05 19:01:01 | RESIDENTIAL (R3) ADDITION/RENOVATION BUILDING REVIEW | | | COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | | COUNTY TO VERIFY IF IMPACT FEES ARE DUE. BRING BACK | | | COUNTY STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES | | | ARE DUE. REQUIRED BY THE COUNTY IMPACT FEE ORDINANCE OF | | | THE UNIFIED LAND DEVELOPMENT CODE. | | | | | | 2- SPECIFY SIZE OF ENTRY DOOR TO VERIFY COMPLIANCE WITH | | | SEC. R311 OF 2010 FBC-RESIDENTIAL. | | | | | | 4- PROVIDE COMPLETE WALL SECTION FOR NEW CONSTRUCTION | | | (SEC. 107.3.5.3(5) CITY AMENDMENTS) SPECIFYING: | | | A) ALL CONNECTORS (TOP/BOTTOM). | | | | | | B) STUCCO THICKNESS. | | | | | | C), 2 LAYERS OF VAPOR BARRIER, | | | | | | D) CLEARANCE FROM FINISHED GRADE, | | | | | | E) ATTIC VENTILATION, SIZE AND SPACING. | | | | | | 5- NOTE: WALL SECTION PROVIDED IS FOR THE EXISTING | | | WALLS AND IS MISSING ALL THIS INFORMATION ALSO. | | | | | | 6- PROVIDE ENERGY CALCULATIONS. SEC. 103.2 OF 2010 | | | FBC-ENERGY CONSERVATION. | | | ***COORDINATE WITH FLOOR PLANS. | | | | | | 7- THIS DWELLING UNIT DOESN'T PROVIDE A LEAST ONE ROOM | | | WITH 120 S.F. AS REQUIRED BY SEC. R304.1 OF 2010 | | | FBC-RESIDENTIAL. REVISE AS REQUIRED. | | | | | | 8- SPECIFY HOW PROVIDING HEAT AS REQUIRED BY SEC. | | | R303.8 OF 2010 FBC-RESIDENTIAL. | | | ***NOTE: PORTABLE WALL UNIT IS NOT ALLOWED. | | | | | | 9- PROVIDE COMPLETE WINDOW/DOOR FRAMING DETAILS. SEC. | | | 107.2.1 CITY AMENDMENTS TO FBC. | | | | | | 10- PROVIDE COMPLETE GABLE END CONSTRUCTION DETAIL TO | | | SHOW HOW ARE THE LOADS TRANSFERED AS REQUIRED BY SEC. | | | R601.2 OF 2010 FBC-RESIDENTIAL. SPECIFY ALL CONNECTORS. | | | | | | 11- SHEET #2: | | | A) ROOF SHEATHING NAILING NOTE IS MISSING ROOF ZONE #3. | | | SPECIFY NAILING FOR ROOF ZONE #3 AS REQUIRED BY SEC. | | | R803.2.3.1 OF 2010 FBC-RESIDENTIAL. | | | | | | B) ZONE #3 IS 5'-0" MIN. AS REQUIRED BY FIGURE | | | R803.2.3.1 OF 2010 FBC-RESIDENTIAL. IDENTIFY ROOF ZONE | | | #3 ON ROOF FRAMING PLAN. | | | | | | 12- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | DCA RULE 9N-3 FOR: | | | A) ROOF SHINGLES. NOA 11-1122.04 SUBMITTED WAS | | | SUPERSEDED BY MIAMI-DADE. NEED TO PROVIDE CURRENT NOA. | | | | | | B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON | | | PLANS, SECTIONS, DETAILS. | | | | | | 13- ENGINEER OF RECORD TO REVIEW AND APPROVED ABOVE | | | PRODUCT APPROVALS. SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH ITEM | | | TO EXPEDITE THE REVIEW PROCESS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2013-09-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-09-10 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-09-10 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2013-09-10 10:21:14 | RED-LINED PLANS | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2013-09-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-09-03 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-09-03 |
Time |
12:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2013-08-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-08-13 |
Time |
07:17 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-08-12 |
Time |
17:57 |
Sent To |
|
|
| Notes |
| 2013-08-13 07:17:33 | 2010 FBC / 2008 NEC | | | | | | DENIED BY ELECTRICAL | | | | | | 1) SHOW THE LOCATION OF THE METER CAN AND SERVICE | | | DISCONNECT ON THE PLANS. NEC 230.70 | | | | | | 2) SHOW THE LOCATION OF THE PANELBOARD ON THE PLANS. | | | NEC 240.24 | | | | | | 3) SHOW COMPLIANCE WITH NEC 210.52 (E) (1) WHICH | | | REQUIRES AT LEAST ONE RECEPTACLE AT THE FRONT AND REAR | | | OF THE DWELLING. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2013-09-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-09-10 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-09-10 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2013-09-10 14:19:42 | SUBMITTED PLANS WITH IMPACT FEES STAMP. NO FEES DUE. | | | SEE PLANS. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-09-09 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-09-09 |
Time |
18:48 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-09-04 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2013-09-04 10:57:34 | *******EXPEDITED******** | | | | | | TO JG DESK | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-09-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-09-03 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-08-16 |
Time |
16:48 |
Sent To |
|
|
| Notes |
| 2013-08-16 16:48:58 | INCOMING SENT TO R24 BOX. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-08-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-08-13 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-08-02 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2013-08-13 15:11:53 | ZONING REVIEW DONE ON 8/13/13. JG. | | 2013-08-05 13:32:42 | **** E X P E D I T E D **** | | | | | | R20 | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
P |
Date |
2013-09-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-09-10 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-09-10 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2013-09-10 14:20:28 | PLANS WITH IMPACT FEES STAMP SUBMITTED. NO FEES DUE. | | | JG. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2013-09-09 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-09-09 |
Time |
18:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-09-09 |
Time |
18:42 |
Sent To |
|
|
| Notes |
| 2013-09-09 18:42:26 | BRING PLANS TO PALM BEACH COUNTY TO VERIFY IF IMPACT | | | FEES ARE DUE. BRING BACK COUNTY STAMPED PLANS AND COPY | | | OF PAID RECEIPT IF FEES ARE DUE. REQUIRED BY THE COUNTY | | | IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT | | | CODE. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2013-08-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-08-27 |
Time |
18:46 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-08-27 |
Time |
18:46 |
Sent To |
|
|
| Notes |
| 2013-08-27 18:46:32 | BRING PLANS TO PALM BEACH COUNTY TO VERIFY IF IMPACT | | | FEES ARE DUE. BRING BACK COUNTY STAMPED PLANS AND COPY | | | OF PAID RECEIPT IF FEES ARE DUE. REQUIRED BY THE COUNTY | | | IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT | | | CODE. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2013-08-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-08-05 |
Time |
18:04 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-08-05 |
Time |
18:04 |
Sent To |
|
|
| Notes |
| 2013-08-05 18:06:44 | BRING PLANS TO PALM BEACH COUNTY TO VERIFY IF IMPACT | | | FEES ARE DUE. BRING BACK COUNTY STAMPED PLANS AND COPY | | | OF PAID RECEIPT IF FEES ARE DUE. REQUIRED BY THE COUNTY | | | IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT | | | CODE. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2013-09-09 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-09-09 |
Time |
18:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-09-09 |
Time |
18:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2013-08-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-08-28 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-08-28 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2013-08-28 09:25:07 | RESIDENTIAL (R3) ADDITION/RENOVATION, PLUMBING SECOND | | | REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- PLUMBING RISER DIAGRAM SUBMITTED DOESN'T MATCH | | | FIXTURE LAYOUT SHOWING ON THE FLOOR PLAN. REVISE AS | | | REQUIRED. SEC. 107.2.1 CITY AMENDMENTS TO FBC. (NOT | | | ADDRESSED. PROVIDE CLEAR AND CORRECT PLUMBING RISER | | | DIAGRAM). | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2013-08-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-08-06 |
Time |
17:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-08-06 |
Time |
17:42 |
Sent To |
|
|
| Notes |
| 2013-08-06 17:45:33 | RESIDENTIAL (R3) ADDITION/RENOVATION, PLUMBING REVIEW | | | COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- PLUMBING RISER DIAGRAM SUBMITTED DOESN'T MATCH | | | FIXTURE LAYOUT SHOWING ON THE FLOOR PLAN. REVISE AS | | | REQUIRED. SEC. 107.2.1 CITY AMENDMENTS TO FBC. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2013-08-27 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2013-08-27 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2013-08-27 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2013-08-27 11:41:34 | PROVISO: LA DRAWINGS SHALL BE SUBMITTED FOR APPROVAL | | | BEFORE CO. | | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | | APONTE AT 561-822-1439. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2013-08-13 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2013-08-13 |
Time |
12:00 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2013-08-13 |
Time |
12:00 |
Sent To |
|
|
| Notes |
| 2013-08-13 12:01:49 | 1. PLEASE SUBMIT LANDSCAPE DRAWINGS TO CONFIRM | | | COMPLIANCE. | | | 2. ONE UNIT ALLOWED ON 420 10TH STREET, 2 UNITS ON 422 | | | 10TH STREET, AND 1 UNIT ON 418 10TH STREET. | | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | | APONTE AT 561-822-1439. |
|
|