Plan Review Details - Permit 13080082
Plan Review Stops For Permit 13080082
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2013-09-09 Cont ID  
Sent By jgomez Date 2013-09-09 Time 17:05 Rev Time 0.00
Received By jgomez Date 2013-09-09 Time 17:05 Sent To  
Notes
2013-09-09 17:10:53BUILDING REVIEW APPROVED WITH PROVISO:
  
 1- SHEET #2: REVISE ALL ROOF SHEATHING NAILING
 SPECIFICATIONS. SPECIFY 8D RING SHANK NAILS MIN.
 ENGINEER TO PROVIDE COMPLETE ENGINEERING ANALYSIS FOR
 ANY OTHER ALTERNATIVE NAILS.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2013-08-28 Cont ID  
Sent By jgomez Date 2013-08-27 Time 18:39 Rev Time 0.00
Received By jgomez Date 2013-08-27 Time 18:39 Sent To  
Notes
2013-08-27 18:40:39RESIDENTIAL (R3) ADDITION/ALTERATION, SECOND BUILDING
 REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- PROVIDE ENERGY CALCULATIONS. SEC. 103.2 OF 2010
 FBC-ENERGY CONSERVATION. (NO ADDRESSED).
 ***AND COORDINATE WITH FLOOR PLANS.
  
 2- PROVIDE COMPLETE WINDOW/DOOR FRAMING DETAILS. SEC.
 107.2.1 CITY AMENDMENTS TO FBC.
 ***HEADER FRAMING DETAIL IS MISSING STUDS. DETAIL ON
 SHEET NO 2 IS ONLY SHOWING ONE STUD SUPPORTING THE
 HEADER. REVISE AS REQUIRED.
  
 3- SHEET #2:
 A) REVISE ALL ROOF SHEATHING NAILING SPECIFICATIONS.
 NEED TO USE 8D RING SHANK NAILS MIN. (ALL OTHER NAILS
 SPECIFIED ON PLYWOOD NAILING REQUIREMENTS ARE NOT
 ALLOWED). AND ROOF ZONE #3 NAIL SPACING IS 4"O.C. SEE
 SEC. R803.2.3.1 OF 2010 FBC-RESIDENTIAL.
  
 B) ROOF DIAGRAM IS MISSING ROOF ZONE #3 ON THE HIP
 ROOF. SEE FIGURE R301.2(7) AND REVISE AS REQUIRED.
  
 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) ROOF SHINGLES. NOA 11-1122.04 SUBMITTED WAS
 SUPERSEDED BY MIAMI-DADE. NEED TO PROVIDE CURRENT NOA.
 (NOT ADDRESSED).
  
 B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON
 PLANS, SECTIONS, DETAILS. (NOT ADDRESSED).
  
 5- ENGINEER OF RECORD TO REVIEW AND APPROVED ABOVE
 PRODUCT APPROVALS. SEC. 107.3.4.1 CITY AMENDMENTS.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH ITEM
 TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-08-05 Cont ID  
Sent By jgomez Date 2013-08-05 Time 18:07 Rev Time 0.00
Received By jgomez Date 2013-08-05 Time 17:42 Sent To  
Notes
2013-08-05 19:01:01RESIDENTIAL (R3) ADDITION/RENOVATION BUILDING REVIEW
 COMMENTS.
 CODE: 2010 FBC.
  
 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY TO VERIFY IF IMPACT FEES ARE DUE. BRING BACK
 COUNTY STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES
 ARE DUE. REQUIRED BY THE COUNTY IMPACT FEE ORDINANCE OF
 THE UNIFIED LAND DEVELOPMENT CODE.
  
 2- SPECIFY SIZE OF ENTRY DOOR TO VERIFY COMPLIANCE WITH
 SEC. R311 OF 2010 FBC-RESIDENTIAL.
  
 4- PROVIDE COMPLETE WALL SECTION FOR NEW CONSTRUCTION
 (SEC. 107.3.5.3(5) CITY AMENDMENTS) SPECIFYING:
 A) ALL CONNECTORS (TOP/BOTTOM).
  
 B) STUCCO THICKNESS.
  
 C), 2 LAYERS OF VAPOR BARRIER,
  
 D) CLEARANCE FROM FINISHED GRADE,
  
 E) ATTIC VENTILATION, SIZE AND SPACING.
  
 5- NOTE: WALL SECTION PROVIDED IS FOR THE EXISTING
 WALLS AND IS MISSING ALL THIS INFORMATION ALSO.
  
 6- PROVIDE ENERGY CALCULATIONS. SEC. 103.2 OF 2010
 FBC-ENERGY CONSERVATION.
 ***COORDINATE WITH FLOOR PLANS.
  
 7- THIS DWELLING UNIT DOESN'T PROVIDE A LEAST ONE ROOM
 WITH 120 S.F. AS REQUIRED BY SEC. R304.1 OF 2010
 FBC-RESIDENTIAL. REVISE AS REQUIRED.
  
 8- SPECIFY HOW PROVIDING HEAT AS REQUIRED BY SEC.
 R303.8 OF 2010 FBC-RESIDENTIAL.
 ***NOTE: PORTABLE WALL UNIT IS NOT ALLOWED.
  
 9- PROVIDE COMPLETE WINDOW/DOOR FRAMING DETAILS. SEC.
 107.2.1 CITY AMENDMENTS TO FBC.
  
 10- PROVIDE COMPLETE GABLE END CONSTRUCTION DETAIL TO
 SHOW HOW ARE THE LOADS TRANSFERED AS REQUIRED BY SEC.
 R601.2 OF 2010 FBC-RESIDENTIAL. SPECIFY ALL CONNECTORS.
  
 11- SHEET #2:
 A) ROOF SHEATHING NAILING NOTE IS MISSING ROOF ZONE #3.
 SPECIFY NAILING FOR ROOF ZONE #3 AS REQUIRED BY SEC.
 R803.2.3.1 OF 2010 FBC-RESIDENTIAL.
  
 B) ZONE #3 IS 5'-0" MIN. AS REQUIRED BY FIGURE
 R803.2.3.1 OF 2010 FBC-RESIDENTIAL. IDENTIFY ROOF ZONE
 #3 ON ROOF FRAMING PLAN.
  
 12- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) ROOF SHINGLES. NOA 11-1122.04 SUBMITTED WAS
 SUPERSEDED BY MIAMI-DADE. NEED TO PROVIDE CURRENT NOA.
  
 B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON
 PLANS, SECTIONS, DETAILS.
  
 13- ENGINEER OF RECORD TO REVIEW AND APPROVED ABOVE
 PRODUCT APPROVALS. SEC. 107.3.4.1 CITY AMENDMENTS.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH ITEM
 TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2013-09-10 Cont ID  
Sent By rmcdouga Date 2013-09-10 Time 10:20 Rev Time 0.00
Received By rmcdouga Date 2013-09-10 Time 10:20 Sent To  
Notes
2013-09-10 10:21:14RED-LINED PLANS
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2013-09-03 Cont ID  
Sent By rmcdouga Date 2013-09-03 Time 12:53 Rev Time 0.00
Received By rmcdouga Date 2013-09-03 Time 12:24 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2013-08-13 Cont ID  
Sent By rmcdouga Date 2013-08-13 Time 07:17 Rev Time 0.00
Received By rmcdouga Date 2013-08-12 Time 17:57 Sent To  
Notes
2013-08-13 07:17:332010 FBC / 2008 NEC
  
 DENIED BY ELECTRICAL
  
 1) SHOW THE LOCATION OF THE METER CAN AND SERVICE
 DISCONNECT ON THE PLANS. NEC 230.70
  
 2) SHOW THE LOCATION OF THE PANELBOARD ON THE PLANS.
 NEC 240.24
  
 3) SHOW COMPLIANCE WITH NEC 210.52 (E) (1) WHICH
 REQUIRES AT LEAST ONE RECEPTACLE AT THE FRONT AND REAR
 OF THE DWELLING.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2013-09-10 Cont ID  
Sent By jgomez Date 2013-09-10 Time 14:18 Rev Time 0.00
Received By jgomez Date 2013-09-10 Time 14:18 Sent To  
Notes
2013-09-10 14:19:42SUBMITTED PLANS WITH IMPACT FEES STAMP. NO FEES DUE.
 SEE PLANS. JG.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2013-09-09 Cont ID  
Sent By jgomez Date 2013-09-09 Time 18:48 Rev Time 0.00
Received By jgomez Date 2013-09-04 Time 10:57 Sent To  
Notes
2013-09-04 10:57:34*******EXPEDITED********
  
 TO JG DESK
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-09-03 Cont ID  
Sent By rmcdouga Date 2013-09-03 Time 12:53 Rev Time 0.00
Received By rmcdouga Date 2013-08-16 Time 16:48 Sent To  
Notes
2013-08-16 16:48:58INCOMING SENT TO R24 BOX. JW

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-08-13 Cont ID  
Sent By jgomez Date 2013-08-13 Time 15:10 Rev Time 0.00
Received By jgomez Date 2013-08-02 Time 13:32 Sent To  
Notes
2013-08-13 15:11:53ZONING REVIEW DONE ON 8/13/13. JG.
2013-08-05 13:32:42**** E X P E D I T E D ****
  
 R20
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status P Date 2013-09-10 Cont ID  
Sent By jgomez Date 2013-09-10 Time 14:20 Rev Time 0.00
Received By jgomez Date 2013-09-10 Time 14:19 Sent To  
Notes
2013-09-10 14:20:28PLANS WITH IMPACT FEES STAMP SUBMITTED. NO FEES DUE.
 JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2013-09-09 Cont ID  
Sent By jgomez Date 2013-09-09 Time 18:42 Rev Time 0.00
Received By jgomez Date 2013-09-09 Time 18:42 Sent To  
Notes
2013-09-09 18:42:26BRING PLANS TO PALM BEACH COUNTY TO VERIFY IF IMPACT
 FEES ARE DUE. BRING BACK COUNTY STAMPED PLANS AND COPY
 OF PAID RECEIPT IF FEES ARE DUE. REQUIRED BY THE COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2013-08-27 Cont ID  
Sent By jgomez Date 2013-08-27 Time 18:46 Rev Time 0.00
Received By jgomez Date 2013-08-27 Time 18:46 Sent To  
Notes
2013-08-27 18:46:32BRING PLANS TO PALM BEACH COUNTY TO VERIFY IF IMPACT
 FEES ARE DUE. BRING BACK COUNTY STAMPED PLANS AND COPY
 OF PAID RECEIPT IF FEES ARE DUE. REQUIRED BY THE COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2013-08-05 Cont ID  
Sent By jgomez Date 2013-08-05 Time 18:04 Rev Time 0.00
Received By jgomez Date 2013-08-05 Time 18:04 Sent To  
Notes
2013-08-05 18:06:44BRING PLANS TO PALM BEACH COUNTY TO VERIFY IF IMPACT
 FEES ARE DUE. BRING BACK COUNTY STAMPED PLANS AND COPY
 OF PAID RECEIPT IF FEES ARE DUE. REQUIRED BY THE COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.

Review Stop P PLUMBING
Rev No 3 Status P Date 2013-09-09 Cont ID  
Sent By jgomez Date 2013-09-09 Time 18:42 Rev Time 0.00
Received By jgomez Date 2013-09-09 Time 18:42 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2013-08-28 Cont ID  
Sent By jgomez Date 2013-08-28 Time 09:23 Rev Time 0.00
Received By jgomez Date 2013-08-28 Time 09:23 Sent To  
Notes
2013-08-28 09:25:07RESIDENTIAL (R3) ADDITION/RENOVATION, PLUMBING SECOND
 REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- PLUMBING RISER DIAGRAM SUBMITTED DOESN'T MATCH
 FIXTURE LAYOUT SHOWING ON THE FLOOR PLAN. REVISE AS
 REQUIRED. SEC. 107.2.1 CITY AMENDMENTS TO FBC. (NOT
 ADDRESSED. PROVIDE CLEAR AND CORRECT PLUMBING RISER
 DIAGRAM).
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop P PLUMBING
Rev No 1 Status F Date 2013-08-06 Cont ID  
Sent By jgomez Date 2013-08-06 Time 17:42 Rev Time 0.00
Received By jgomez Date 2013-08-06 Time 17:42 Sent To  
Notes
2013-08-06 17:45:33RESIDENTIAL (R3) ADDITION/RENOVATION, PLUMBING REVIEW
 COMMENTS.
 CODE: 2010 FBC.
  
 1- PLUMBING RISER DIAGRAM SUBMITTED DOESN'T MATCH
 FIXTURE LAYOUT SHOWING ON THE FLOOR PLAN. REVISE AS
 REQUIRED. SEC. 107.2.1 CITY AMENDMENTS TO FBC.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop Z ZONING
Rev No 2 Status P Date 2013-08-27 Cont ID  
Sent By aaponte Date 2013-08-27 Time 11:40 Rev Time 0.00
Received By aaponte Date 2013-08-27 Time 11:40 Sent To  
Notes
2013-08-27 11:41:34PROVISO: LA DRAWINGS SHALL BE SUBMITTED FOR APPROVAL
 BEFORE CO.
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.

Review Stop Z ZONING
Rev No 1 Status F Date 2013-08-13 Cont ID  
Sent By aaponte Date 2013-08-13 Time 12:00 Rev Time 0.00
Received By aaponte Date 2013-08-13 Time 12:00 Sent To  
Notes
2013-08-13 12:01:491. PLEASE SUBMIT LANDSCAPE DRAWINGS TO CONFIRM
 COMPLIANCE.
 2. ONE UNIT ALLOWED ON 420 10TH STREET, 2 UNITS ON 422
 10TH STREET, AND 1 UNIT ON 418 10TH STREET.
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.