Plan Review Details - Permit 13071177
Plan Review Stops For Permit 13071177
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-10-23 Cont ID  
Sent By jgomez Date 2013-10-25 Time 09:45 Rev Time 0.00
Received By jgomez Date 2013-10-23 Time 09:45 Sent To  
Notes
2013-10-23 10:14:36BUILDING REVIEW APPROVED WITH PROVISO:
  
 1- HORIZONTAL SLIDING WINDOWS SIZE NOT TO EXCEED
 MAXIMUM SIZE SHOWN ON PRODUCT APPROVAL SUBMITTED.
 OTHERWISE A NEW PRODUCT APPROVAL IS REQUIRED. JG.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-08-16 Cont ID  
Sent By jgomez Date 2013-08-16 Time 15:29 Rev Time 0.00
Received By jgomez Date 2013-08-16 Time 15:04 Sent To  
Notes
2013-08-16 15:31:09RESIDENTIAL (R3) ADDITION, BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY TO VERIFY IF IMPACT FEES ARE DUE. BRING BACK
 COUNTY STAMPED PLANS AND COPY OF THE PAID RECEIPT IF
 FEES ARE DUE. REQUIRED BY THE COUNTY IMPACT FEE
 ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE.
  
 2- PROVIDE ENERGY CALCULATIONS. SEC. 101.4.3 OF 2010
 FBC-ENERGY CONSERVATION.
  
 3- SHEET A-1:
 A) REVISE THE DESIGN PRESSURES FOR WINDOWS AND DOORS.
 THEY DON'T CORRESPOND TO WORST CASE SCENARIO FOR
 EXPOSURE "C". PROVIDE CALCULATIONS. SEC. R301.1 OF 2010
 FBC-RESIDENTIAL.
  
 B) REVISE THE ROOF DESIGN PRESSURES. THEY DON'T
 CORRESPOND TO EXPOSURE "C". AND, ROOF ZONE 2 AND ROOF
 ZONE 3 HAVE NOT THE SAME DESIGN PRESSURES. PROVIDE
 CALCULATIONS. SEC. R301.1.
  
 C) REVISE THE DIMENSION FOR ROOF ZONES 2 AND 3. NEED TO
 SPECIFY 4'-0" MIN. SEE NOTE "A" ON FIGURE R301.2(7) OF
 2010 FBC-RESIDENTIAL.
  
 D) SPECIFY ALL DEAD LOADS, LIVE LOADS, INCLUDING THE
 ATTIC LIVE LOADS AS REQUIRED BY SEC. R301.1 AND TABLE
 R301.5 OF 2010 FBC. RESIDENTIAL.
  
 E) THIS IS NOT ALTERATION LEVEL 3. THIS IS AN ADDITION.
 SEC. 407 OF 2010 FBC-EXISTING BUILDING. REVISE AS
 REQUIRED.
  
 F) CLARIFY HOW ARE THE NEW SKYLIGHTS GOING TO BE
 INSTALLED IN THE EXISTING BATHROOM IF THE ROOF CRICKET
 IS ABOVE THE BATHROOM. PROVIDE COMPLETE FRAMING DETAILS
 AND SPECIFICATIONS. SEC. 107.2.1 CITY AMENDMENTS TO
 FBC.
  
 G) PROVIDE SPECIFICATIONS FOR THE EXISTING BATHROOM
 VENTILATION AS REQUIRED BY SEC. R303.3 OF 2010
 FBC-RESIDENTIAL.
  
 H) PROVIDE COMPLETE FRAMING DETAILS AND SPECIFICATIONS
 FOR THE WOOD DECK CONSTRUCTION. SPECIFY ALL FRAMING
 MEMBER AND CONNECTORS. SEC. 107.2.1 CITY AMENDMENTS.
  
 I) PROVIDE FRAMING DETAILS FOR THE NEW ATTIC PULL DOWN
 STAIRS. SEC. 107.2.1 CITY AMENDMENTS.
  
 J) SPECIFY SIZE OF ATTIC ACCESS. SEC. R807 OF 2010 FBC.
  
 K) GUEST ROOM EGRESS WINDOWS DON'T COMPLY WITH SEC.
 R310.
  
 4- SHEET A-2:
 A) ROOF PITCH OF 3:12 REQUIRES TWO LAYERS OF
 UNDERLAYMENT. SEC. R905.2.2.
  
 B) SPECIFY FIREBLOCKING IN TYPICAL WALL SECTION. SEC.
 R302.11
  
 C) SPECIFY WALL INSULATION IN THE TYPICAL WALL SECTION.
 COORDINATE WITH THE ENERGY CALCULATIONS. SEC. 103.2.2
 OF 2010 FBC-ENERGY CONSERVATION.
  
 D) SPECIFY HOW IS THE PLYWOOD SOFFIT ATTACHED. SEC.
 107.2.1 CITY AMENDMENTS. ACCORDING TO TYPICAL WALL
 SECTION SUBMITTED PLYWOOD SOFFIT IS NOT ATTACHED TO ANY
 FRAMING MEMBER.
  
 5- SHEET S-2:
 A) REVISE NAILING ZONE SPECIFICATIONS. NEED TO SPECIFY
 8D RING SHANK MIN. SEC. R803.2.3.1. ALSO, IS MISSING
 NAIL ZONE #3.
  
 B) SPECIFY CONNECTOR FOR FOR 3X8 RAFTERS RESTING AT THE
 (3)2X12 BEAM AT NEW FRONT PORCH. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 C) REVISE ROOF SHEATHING SPECIFICATION SHOWN ON ROOF
 FRAMING PLAN BY THE FRONT PORCH AND REAR ADDITION. NEED
 TO MATCH REVISED NAILING ZONE SPECIFICATIONS. SEE ITEM
 #5(A) ABOVE.
  
 D) SPECIFY BEAMS FOR NEW COVERED AREA IN THE REAR
 ADDITION. SEC. 107.2.1 CITY AMENDMENTS.
  
 6- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) SKYLIGHT IN EXISTING BATHROOM AS SHOWN ON PLANS. NOA
 08-0219.02 SUBMITTED EXPIRED ON 5/15/2013. NEED CURRENT
 NOA.
  
 B) HORIZONTAL SLIDING WINDOWS AS SHOWN ON PLANS.
 INCLUDING THE SIZE SHOWN ON THE SITTING AREA.
  
 C) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON
 PLANS, DETAILS, ETC. ***NOTE; PROVIDE ONLY THE PRODUCT
 APPROVAL COVER PAGE AND PAGE SHOWING THE SPECIFIED
 CONNECTOR.
  
 7- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS. SEC.
 107.3.4.21 CITY AMENDMENTS.
  
 8- SPECIFY CARBON MONOXIDE ALARMS, INCLUDING THE
 EXISTING BEDROOMS AS REQUIRED BY SEC. R315.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2013-10-23 Cont ID  
Sent By rmcdouga Date 2013-10-23 Time 13:31 Rev Time 0.00
Received By rmcdouga Date 2013-10-23 Time 13:31 Sent To  
Notes
2013-10-23 13:32:42RED-LINE AND RESTAMP NEW ELECTRICAL SHEETS.
2013-10-09 18:25:44NEW SHEETS SUBMITTED. JG.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2013-09-04 Cont ID  
Sent By rmcdouga Date 2013-09-04 Time 09:51 Rev Time 0.00
Received By rmcdouga Date 2013-09-04 Time 09:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-10-23 Cont ID  
Sent By jgomez Date 2013-10-23 Time 13:46 Rev Time 0.00
Received By jgomez Date 2013-10-09 Time 18:23 Sent To  
Notes
2013-10-09 18:24:21RESUBMITTAL SENT TO R14 SHELF FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-09-04 Cont ID  
Sent By rmcdouga Date 2013-09-04 Time 09:51 Rev Time 0.00
Received By rmcdouga Date 2013-07-31 Time 11:44 Sent To  
Notes
2013-08-01 11:45:32INCOMING SENT TO R01 BOX. JW

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2013-10-23 Cont ID  
Sent By jgomez Date 2013-10-23 Time 10:14 Rev Time 0.00
Received By jgomez Date 2013-10-23 Time 10:14 Sent To  
Notes
2013-10-23 10:15:30MU-2013-021646. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2013-08-16 Cont ID  
Sent By jgomez Date 2013-08-16 Time 15:28 Rev Time 0.00
Received By jgomez Date 2013-08-16 Time 15:26 Sent To  
Notes
2013-08-16 15:29:14BRING PLANS TO PALM BEACH COUNTY TO VERIFY IF IMPACT
 FEES ARE DUE. BRING BACK COUNTY STAMPED PLANS AND COPY
 OF PAID RECEIPT IF FEES ARE DUE. JG.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2013-10-25 Cont ID  
Sent By jgomez Date 2013-10-25 Time 12:40 Rev Time 0.00
Received By jgomez Date 2013-10-23 Time 12:31 Sent To  
Notes
2013-10-23 12:42:19MECHANICAL REVIEW APPROVED WITH PROVISO:
  
 1- REVISE A/C PLAN TO SHOW EQUIPMENT LISTED IN THE
 EQUIPMENT SIZING CALCULATIONS. JG.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2013-08-20 Cont ID  
Sent By jgomez Date 2013-08-20 Time 17:26 Rev Time 0.00
Received By jgomez Date 2013-08-20 Time 17:26 Sent To  
Notes
2013-08-20 17:30:56RESIDENTIAL (R3) ADDITION, MECHANICAL REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- PROVIDE EQUIPMENT SIZING CALCULATIONS SHOWING
 EQUIPMENT LISTED IN THE A/C PLAN SUBMITTED. SEC. 403.6
 OF 2010 FBC-ENERGY CONSERVATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop P PLUMBING
Rev No 2 Status P Date 2013-10-23 Cont ID  
Sent By jgomez Date 2013-10-23 Time 12:45 Rev Time 0.00
Received By jgomez Date 2013-10-23 Time 12:45 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2013-08-20 Cont ID  
Sent By jgomez Date 2013-08-20 Time 17:31 Rev Time 0.00
Received By jgomez Date 2013-08-20 Time 17:31 Sent To  
Notes
2013-08-20 17:36:27RESIDENTIAL (R3) ADDITION, PLUMBING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- REVISE PLUMBING RISER DIAGRAM. NOT MORE THAN ONE
 FIXTURE SHALL DISCHARGE UPSTREAM OF THE DRY VENT. SEE
 SEC. P3108.2.1 OF 2010 FBC-RESIDENTIAL.
  
 2- SANITARY RISER DIAGRAM SUBMITTED:
 A) CLEANOUT REQUIRED. SEC. P3005.2
 B) THERE IS NO ABBREVIATION LEGEND. CLARIFY WHAT'S
 "CTG". SEC. 107.2.1 CITY AMENDMENTS TO FBC.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2013-10-23 Cont ID  
Sent By jgomez Date 2013-10-23 Time 13:47 Rev Time 0.00
Received By jgomez Date 2013-10-23 Time 13:46 Sent To  
Notes
2013-10-23 13:47:37ROOFING SHINGLES NOA 13-0419.04 SUBMITTED. JG.

Review Stop Z ZONING
Rev No 2 Status P Date 2013-10-10 Cont ID  
Sent By dkittred Date 2013-10-10 Time 10:40 Rev Time 0.00
Received By dkittred Date 2013-10-10 Time 10:36 Sent To  
Notes
2013-10-10 13:48:51LANDSCAPE PLAN RECEIVED FOR REVIEW - 10/10/13. DK
2013-10-10 10:40:07PLANNING AND ZONING COMMENTS 10/10/13
  
 LANDSCAPE PLAN MISSING - SPOKE WITH APPLICANT 10/09/13
 AND HE WILL BE SUMBMITTING A PLAN SHOWING THE SITE IS
 ALREADY IN COMPLIANCE WITH THE LANDSCAPING
 REQUIREMENTS. DK

Review Stop Z ZONING
Rev No 1 Status F Date 2013-08-07 Cont ID  
Sent By dkittred Date 2013-08-07 Time 10:32 Rev Time 0.00
Received By dkittred Date 2013-08-07 Time 10:19 Sent To  
Notes
2013-08-07 10:38:26PLANNING & ZONING COMMENTS: ****FAILED****
  
 8/7/2013
 THE VALUE OF THE CONSTRUCTION ($69,209) EXCEEDS 50% OF
 THE STRUCTURE'S VALUE ($72,856) ACCORDING TO THE P.B.C.
 PROPERTY APPRAISER'S OFFICE; THEREFORE, PURSUANT TO
 SECTION 94-441(C)(2) OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS (ZLDR), THE LANDSCAPE ON THE SITE SHALL BE
 IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS FOUND IN
 ARTICLE XIV OF THE ZLDR. IF THE SITE CONFORMS TO
 ARTICLE XIV, THEN TWO (2) COPIES OF A LANDSCAPE PLAN
 DEMONSTRATING COMPLIANCE SHALL BE INCLUDED WITH THE
 PERMIT RE-SUBMITTAL. IF THE SITE DOES NOT CONFORM TO
 ARTICLE XIV, THEN PRIOR TO THE ZONING APPROVAL OF THIS
 PERMIT A SEPARATE LANDSCAPE PERMIT AND IRRIGATION
 PERMIT SHALL BE SUBMITTED SHOWING MATERIAL TO BRING THE
 SITE INTO CONFORMITY.
  
 NOTE: ZLDR SEC. 94-442(B)(2)A. - LANDSCAPING
 REQUIREMENTS FOR SINGLE FAMILY DWELLING UNITS IS ONE
 SHADE, FLOWERING, OR FRUIT TREE PLANTED FOR EACH 1,200
 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF AND ONE
 SHRUB PLANTED FOR EACH 500 SQUARE FEET OF OPEN SPACE OR
 PORTION THEREOF.
  
 IF ANY TREES WILL BE REMOVED FOR THE NEW CONSTRUCTION,
 A TREE ALTERATION PERMIT WILL BE REQUIRED THROUGHT THE
 PLANNING & ZONING DEPT.
  