| Plan Review Stops For Permit 13071155 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2013-08-27 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-08-27 |
Time |
06:59 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-08-27 |
Time |
06:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-08-15 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-08-15 |
Time |
18:58 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-08-15 |
Time |
18:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2013-08-27 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-08-27 |
Time |
06:59 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-08-27 |
Time |
06:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2013-08-15 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2013-08-21 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-08-15 |
Time |
18:51 |
Sent To |
Z |
|
| Notes |
| 2013-08-15 18:58:40 | A DISCONNECT IS REQUIRED TO BE IN SIGHT OF SIGN | | | (OUTSIDE) AS WELL AS THE DRIVERS (INSIDE). PROVIDE | | | ENGINEERED DRAWINGS FROM A REGISTERED FLORIDA ENGINEER | | | FOR ATTACHEMENT AND WINDLOAD SPECIFICATIONS. PROVIDE | | | DETAILS OF ATTACHEMENTS FOR FASTENER SPACING AND | | | LOCATIONS, INCLUDING EDGE DISTANCE. PROVIDE ELECTRICAL | | | LOAD FOR EACH SIGN AND APPROPRIATE LED DRIVERS FOR EACH | | | SET OF LEDS. INSUFFICIENT INFORMATION HAS BEEN PROVIDED | | | FOR A COMPLETE REVIEW TO BE COMPLETED. PLEASE PROVIDE | | | ALL OF THE INFORMATION NEEDED FOR FBC 1609 EVALUATION | | | AND APPROVAL AND NEC 600 INFORMATION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-08-27 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-08-27 |
Time |
06:59 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-08-23 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2013-08-27 06:59:43 | TO J WITMER | | 2013-08-23 10:49:22 | SENT TO ZONING SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-08-16 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2013-08-16 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2013-07-31 |
Time |
15:24 |
Sent To |
|
|
| Notes |
| 2013-08-15 11:07:55 | 8/15 TO DOUG HARVEY'S DESK | | | | | 2013-07-31 15:24:29 | ZONING BOX. JW |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2013-08-26 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2013-08-26 |
Time |
16:37 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2013-08-26 |
Time |
10:47 |
Sent To |
E |
|
| Notes |
| 2013-08-26 17:02:18 | EAST FACADE - EXTERIOR SIGN - COMPLIES | | | | | | ALLOWED - 49.58 SQ. FT. | | | PROPOSED - 30.375 SQ. FT. | | | | | | EAST FACADE - INTERIOR SIGNS - COMPLY | | | | | | ALLOWED - 49.58 SQ. FT. | | | PROPOSED TB SCRIPT - 7.42 SQ. FT. (3.71 SQ. FT. X 2) | | | PROPOSED MARLIN LOGOS - 2.32 SQ. FT. (1.16 SQ. FT. X 2) | | | PROPOSED WINDOW VINYL - 1.21 SQ. FT. | | | | | | TOTAL: 10.95 SQ. FT. | | | | | | NORTH FACADE - EXTERIOR SIGNS - COMPLY | | | | | | ALLOWED - 35.67 SQ. FT. | | | PROPOSED TB SCRIPT - 15.57 SQ. FT. | | | PROPOSED WINDOW VINYL - 1.21 SQ. FT. | | | | | | TOTAL - 16.78 SQ. FT. | | | | | | PEDESTRIAN BLADE SIGN - COMPLIES | | | | | | ALLOWED - 4 SQ. FT. | | | PROPOSED - 4 SQ. FT. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | 2013-08-26 10:47:58 | ZONING RECEIVED. GIVEN TO ESCHNEIDER FOR REVIEW. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2013-08-21 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2013-08-21 |
Time |
13:38 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2013-08-21 |
Time |
13:38 |
Sent To |
B |
|
| Notes |
| 2013-08-21 15:31:02 | FAILED | | | | | | THERE ARE 2 DIFFERENT SETS OF PLANS PROVIDED WHICH DO | | | NOT MATCH IN SIGN SIZE OR INSTALLATION METHOD. PLEASE | | | PROVIDE THE VERSION THAT STAFF IS TO REVIEW. PLEASE | | | NOTE THAT THE SHEETS CREATED BY SIGNSENSATION AND EASY | | | SEAL ARE NOT CONSISTENT ON THE PAGES THEMSELVES WITH | | | DIMENSION CALCULATIONS. ADDITIONALLY, THERE IS NO BLADE | | | SIGN PROVIDED WITH THE SIGNSENSATION/EASY SEAL PLANS. | | | STAFF IS UNABLE TO APPROVE THE PERMIT WITHOUT KNOWING | | | WHAT NEEDS TO BE REVIEWED. | | | | | | THE RESULTS BELOW ARE BASED ON THE REVIEW OF THE IMAGE | | | FACTOR PLANS. | | | | | | EAST FACADE - EXTERIOR SIGN - COMPLIES | | | | | | ALLOWED - 49.58 SQ. FT. | | | PROPOSED - 30.375 SQ. FT. | | | | | | EAST FACADE - INTERIOR SIGNS - COMPLY | | | | | | ALLOWED - 49.58 SQ. FT. | | | PROPOSED TB SCRIPT - 7.3 SQ. FT. (3.65 SQ. FT. X 2) | | | PROPOSED MARLIN LOGOS - 2.36 SQ. FT. (1.18 SQ. FT. X 2) | | | PROPOSED WINDOW VINYL - 1.23 SQ. FT. | | | | | | TOTAL: 10.89 SQ. FT. | | | | | | NORTH FACADE - EXTERIOR SIGNS - COMPLY | | | | | | ALLOWED - 35.67 SQ. FT. | | | PROPOSED TB SCRIPT - 15.57 SQ. FT. | | | PROPOSED WINDOW VINYL - 1.23 SQ. FT. | | | | | | TOTAL - 16.8 SQ. FT. | | | | | | PEDESTRIAN BLADE SIGN - COMPLIES | | | | | | ALLOWED - 4 SQ. FT. | | | PROPOSED - 4 SQ. FT. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2013-08-16 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2013-08-16 |
Time |
09:18 |
Rev Time |
0.75 |
| Received By |
eschneid |
Date |
2013-08-16 |
Time |
08:04 |
Sent To |
|
|
| Notes |
| 2013-08-16 10:41:24 | FAILED | | | | | | THE CITYPLACE STAMP IS REQUIRED ON THE PLANS. | | | | | | EAST FACADE - EXTERIOR SIGN | | | | | | 1) THE ENTIRE HEIGHT OF THE SIGN SHALL BE PROVIDED. THE | | | SIGN DIMENSION DID NOT INCLUDE THE LENGTH TO THE BOTTOM | | | OF THE "Y". | | | | | | ALLOWED - 49.58 SQ. FT. | | | PROPOSED - UNABLE TO DETERMINE | | | | | | EAST FACADE - INTERIOR SIGNS | | | | | | 2) THE ENTIRE HEIGHT OF THE SIGN AND THE WINDOW VINYL | | | SHALL BE PROVIDED. THE SIGN DIMENSION DID NOT INCLUDE | | | THE LENGTH TO THE BOTTOM OF THE "Y". | | | | | | ALLOWED - 49.58 SQ. FT. | | | PROPOSED TB SCRIPT - UNABLE TO DETERMINE (?? SQ. FT. X | | | 2) | | | PROPOSED MARLIN LOGOS - 2.36 SQ. FT. (1.18 SQ. FT. X 2) | | | PROPOSED WINDOW VINYL - UNABLE TO DETERMINE | | | | | | NORTH FACADE - EXTERIOR SIGNS | | | | | | 3) THE ENTIRE HEIGHT OF THE ILLUMINATED SIGN AND THE | | | WINDOW VINYL SHALL BE PROVIDED. THE SIGN DIMENSION DID | | | NOT INCLUDE THE LENGTH TO THE BOTTOM OF THE "Y". | | | | | | ALLOWED - 35.67 SQ. FT. | | | PROPOSED TB SCRIPT - UNABLE TO DETERMINE | | | PROPOSED WINDOW VINYL - UNABLE TO DETERMINE | | | | | | PEDESTRIAN BLADE SIGN - COMPLIES | | | | | | ALLOWED - 4 SQ. FT. | | | PROPOSED - 4 SQ. FT. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|