Review Stop E ELECTRICAL
Rev No 2 Status P Date 2013-08-12 Cont ID  
Sent By dharvey Date 2013-08-12 Time 15:27 Rev Time 0.00
Received By dharvey Date 2013-08-12 Time 15:27 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2013-07-30 Cont ID  
Sent By dharvey Date 2013-07-30 Time 16:04 Rev Time 0.00
Received By dharvey Date 2013-07-30 Time 15:23 Sent To  
Notes
2013-07-30 16:06:32GIVEN TO J WITMER ALONG WITH 13071064
2013-07-30 16:04:13PROVIDE RECPTACLE SPACING PER 210.52
 (A) GENERAL PROVISIONS. IN EVERY KITCHEN, FAMILY ROOM,
 DINING ROOM, LIVING ROOM, PARLOR, LIBRARY, DEN,
 SUNROOM, BEDROOM, RECREATION ROOM, OR SIMILAR ROOM OR
 AREA OF DWELLING UNITS, RECEPTACLE OUTLETS SHALL BE
 INSTALLED IN ACCORDANCE WITH THE GENERAL PROVISIONS
 SPECIFIED IN 210.52(A)(1) THROUGH (A)(3).
 (1) SPACING. RECEPTACLES SHALL BE INSTALLED SUCH THAT
 NO POINT MEASURED HORIZONTALLY ALONG THE FLOOR LINE IN
 ANY WALL SPACE IS MORE THAN 1.8 M (6 FT) FROM A
 RECEPTACLE OUTLET.
 (2) WALL SPACE. AS USED IN THIS SECTION, A WALL SPACE
 SHALL INCLUDE THE FOLLOWING:
 (1) ANY SPACE 600 MM (2 FT) OR MORE IN WIDTH
 (INCLUDING SPACE MEASURED AROUND CORNERS) AND UNBROKEN
 ALONG THE FLOOR LINE BY DOORWAYS, FIREPLACES, AND
 SIMILAR OPENINGS
 (2) THE SPACE OCCUPIED BY FIXED PANELS IN EXTERIOR
 WALLS, EXCLUDING SLIDING PANELS
 PROVIDE ARC FAULT PROTECTION PER 210.12
 PROVIDE KITCHEN SMALL APPLIANCE AND COUNTERTOP
 RECEPTACLES PER 210.52 B AND GFCI PROTECTION PER 210.8
 PROVIDE EXTERIOR LIGHTING PER 210.70 AND SHOW EXTERIOR
 LIGHTING AND INDICATE METHOD OF CONTROL.
 PROVIDE SWITCHED OUTLETS IN EACH HABITABLE ROOM PER
 210.70, NO SWITCHES ARE CURRENTLY INDICATED
 PROVIDE 20 AMP GFCI PROTECTED RECEPTACLE IN BATHROOM
 PER 210.8. NO SWITCH, LIGHT, EXHAUST OR RECEPTACLE IS
 INDICATED ON THE PLANS
 EMON METER IS A CT TYPE METER AND NOT A FEED THRU AS
 INDICATED ON THE DRAWING
 ANY RESELLING OF ELECTRICITY IS TO COMPLY WITH FLORIDA
 ADMINISTRIVE CODE, STATUTES AND FPL REGULATORY
 STANDARDS
 PROVIDE PANEL DIRECTORY PER 408.4
  
 THIS PLAN IS FOR A CHANGE OF OCCUPANCY FOR THIS UNIT
 AND WILL REPRESENT THE RECORD DRAWING IN THE FILE
 MOVING FORWARD. THE CODE IS THE MINIMUM STANDARD THAT
 MUST BE MET AND REQUIRES COMPLIANCE. ADDITIONALLY,
 NOTES AND SPECIFICATIONS FOUND ON THE PLAN BY THE
 DESIGN PROFESSION NEED TO BE COMPLIED WITH OR
 ELIMINATED FROM THE RECORD DRAWING, INCLUDING PERMITTED
 WIRING METHODS, COLOR CODING AND ALL OTHER
 SPECIFICATIONS SHOWN OR CALLED OUT. IT IS NOT BELIEVED
 THE CURRENT WIRING METHODS, INCLUDING THE USE OF TYPE
 NM CABLE MEET THE SPECIFICATION CALLED OUT BY THE
 DESIGN PROFESSIONAL.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-08-12 Cont ID  
Sent By dharvey Date 2013-08-12 Time 15:27 Rev Time 0.00
Received By dharvey Date 2013-08-05 Time 08:55 Sent To  
Notes
2013-08-12 15:27:43TO J WITMER
2013-08-05 08:55:59TO ELEC
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-08-05 Cont ID  
Sent By shill Date 2013-07-30 Time 08:54 Rev Time 0.00
Received By shill Date 2013-07-30 Time 15:17 Sent To  
Notes
2013-07-30 15:18:07TO DH DESK
  