Plan Review Details - Permit 13070929
| Plan Review Stops For Permit 13070929 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2013-08-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-08-29 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-08-29 |
Time |
08:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2013-08-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-08-12 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-08-12 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2013-08-12 14:23:52 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FROM PREVIOUS LIST: | | | | | | | | | 3. IMPACT PROTECTION REQUIRED,FBC1609.1.4, FBC R | | | 301.2.1.2. IF NON IMPACT GLAZED DOORS OR WINDOWS ARE | | | PROPOSED, PROVIDE PRODUCT APPROVALS AND, IF SHUTTERS | | | ARE USED, COMPLETE THE SAMPLE INSTALLATION SCHEDULE | | | (AVAILABLE IN THE LOBBY AND AT HTTP://WWW.CITYOFWPB.COM | | | /CONSTRUCTION/PDF/SCHEDULE_FOR_INSTALLATION.PDF) | | | | | | 2ND REVIEW, INSTALLATION SCHEDULE NOT SUBMITTED. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-07-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-07-27 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-07-27 |
Time |
12:59 |
Sent To |
|
|
| Notes |
| 2013-07-27 13:01:11 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. NO PLANS OR PRODUCT APPROVALS SUBMITTED, FBC 107, | | | FBC 2010 RESIDENTIAL 301. | | | | | | 2. IF DOORS AND WINDOWS ARE PROPOSED, PROVIDE A FLOOR | | | PLAN SHOWING: WINDOW AND DOOR LOCATIONS, SIZES, WINDOW | | | TYPE, ROOM DESIGNATIONS. NOTE EXISTING CONDITIONS (TYPE | | | OF WINDOW) AND OPENING SIZE FOR BEDROOMS, FBC R310, FBC | | | EB 604.1. THE CLEAR OPENING CANNOT BE REDUCED BY MORE | | | THAN 5%. | | | | | | PROVIDE FLORIDA STATE OR LOCAL PRODUCT APPROVAL FOR | | | DOORS AND WINDOWS, FAC9N-3. | | | | | | 3. IMPACT PROTECTION REQUIRED,FBC1609.1.4, FBC R | | | 301.2.1.2. IF NON IMPACT GLAZED DOORS OR WINDOWS ARE | | | PROPOSED, PROVIDE PRODUCT APPROVALS AND, IF SHUTTERS | | | ARE USED, COMPLETE THE SAMPLE INSTALLATION SCHEDULE | | | (AVAILABLE IN THE LOBBY AND AT HTTP://WWW.CITYOFWPB.COM | | | /CONSTRUCTION/PDF/SCHEDULE_FOR_INSTALLATION.PDF) | | | | | | IF THIS FALLS UNDER THE 25% EXCEPTION FBC EB 606.4, | | | PROVIDE CALCULATIONS. | | | | | | | | | NOT ENOUGH INFORMATION PROVIDED FOR A COMPLETE | | | CHECKLIST. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-08-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-08-29 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-08-21 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2013-08-22 11:44:17 | SENT TO SAMANTHA'S DESK FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-08-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-08-12 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-08-07 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2013-08-07 16:43:56 | INCOMING SENT TO SAMANTHAS' DESK . JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-07-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-07-27 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-07-25 |
Time |
11:56 |
Sent To |
|
|
| Notes |
| 2013-07-25 11:56:58 | ROUTED TO BUILDING UNDER $5000 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |