Plan Review Details - Permit 13070794
| Plan Review Stops For Permit 13070794 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2013-07-29 |
|
|
Cont ID |
|
| Sent By |
JWITMER |
Date |
2013-07-29 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-07-29 |
Time |
13:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2013-08-06 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-08-06 |
Time |
12:31 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-08-06 |
Time |
12:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2013-07-30 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-07-30 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-07-30 |
Time |
15:16 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-08-06 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-08-06 |
Time |
12:31 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-07-22 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2013-08-06 12:32:06 | TO S HILL | | 2013-07-23 13:43:25 | SENT TO B21 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2013-07-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-07-29 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-07-29 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2013-07-29 14:14:00 | PROVISO: | | | 2010 FBC-B 716.4 FIRE DAMPER ACCESS AND IDENTIFICATION. | | | 2010 FBC-M FIRE DAMPER ACCESS AND IDENTIFICATION. | | | FIRE AND SMOKE DAMPERS SHALL BE PROVIDED WITH AN | | | APPROVED MEANS OF ACCESS, WHICH IS LARGE ENOUGH TO | | | PERMIT INSPECTION AND MAINTENANCE OF THE DAMPER AND ITS | | | OPERATING PARTS. THE ACCESS SHALL NOT AFFECT THE | | | INTEGRITY OF FIRE-RESISTANCE-RATED ASSEMBLIES. THE | | | ACCESS OPENINGS SHALL NOT REDUCE THE FIRE-RESISTANCE | | | RATING OF THE ASSEMBLY. ACCESS POINTS SHALL BE | | | PERMANENTLY IDENTIFIED ON THE EXTERIOR BY A LABEL | | | HAVING LETTERS NOT LESS THAN 1/2 INCH (12.7 MM) IN | | | HEIGHT READING: FIRE/SMOKE DAMPER, SMOKE DAMPER OR FIRE | | | DAMPER. ACCESS DOORS IN DUCTS SHALL BE TIGHT FITTING | | | AND SUITABLE FOR THE REQUIRED DUCT CONSTRUCTION. |
|
|
|