Plan Review Details - Permit 13070388
Plan Review Stops For Permit 13070388
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2013-07-23 Cont ID  
Sent By jwitmer Date 2013-07-23 Time 13:23 Rev Time 0.00
Received By jwitmer Date 2013-07-23 Time 10:30 Sent To  
Notes
2013-07-23 13:10:54BUILDING PLAN REVIEW
 PERMIT: 13070388
 ADD: PALM BEACH LAKES BLVD # E-101
 CONT: TBD (TO BE DETERMINED)
 TEL: (###)###-####
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 1ST REVIEW
 DATE: JULY 23/ 2013
 ACTION: BUILDING PROVISOS
  
 1) PB OUTLET MALLS:
 BUILDING PROVISO:
 A LETTER FROM THE QUALIFIER OF BOTH THE SHELL
 CONTRACTOR (EMJ CORPORATION) AND TENANT BUILD-OUT
 CONTRACTOR MUST BE PROVIDED BEFORE TENANT BUILD-OUT
 PERMIT CAN BE ISSUED, IF THE TENANT BUILD-OUT
 CONTRACTOR WISHES TO START WORK BEFORE THE SHELL WORK
 HAS RECEIVED A CERTIFICATE OF COMPLETION, AGREEING THEY
 WILL WORK TOGETHER TO ACHIEVE CODE COMPLIANCE. THESE
 DOCUMENTS WILL NEED TO BE SIGNED BY THE QUALIFIER AND
 NOTARIZED.
  
 2) PROVISO: SHEET A-03 GENERIC ACCESSABLE STALL PLEASE
 REVIEW 2010 FLORIDA ACCESSIBILITY CODE 604.8.1.6
 LAVATORY. FIGURE 604.8.1.6 (GRAY BOX, FLORIDA SPECIFIC
 REQUIREMENT). IN NEW CONSTRUCTION, THE WHEELCHAIR
 ACCESSIBLE TOILET COMPARTMENT SHALL CONTAIN AN
 ACCESSIBLE LAVATORY WITHIN IT, WHICH MUST BE AT LEAST
 19 INCHES WIDE BY 17 INCHES DEEP, NOMINAL SIZE, AND
 WALL-MOUNTED. THE LAVATORY SHALL BE MOUNTED SO AS NOT
 TO OVERLAP THE CLEAR FLOOR SPACE AREAS REQUIRED BY
 SECTION 604 FOR THE WHEELCHAIR ACCESSIBLE TOILET
 COMPARTMENT AND SHALL COMPLY WITH SECTION 606. SUCH
 LAVATORIES SHALL BE COUNTED AS PART OF THE REQUIRED
 FIXTURE COUNT FOR THE BUILDING. SEE ALSO SECTION
 213.3.4.
  
 3A) PROVISO: SHEET A2-1 ACCESSIBLE DRESSING ROOM #9,
 THE DOOR SWINGS OVER INTO THE CLEAR TURNING AREA FOR
 THE WHEEL CHAIR. 2010 FLORIDA ACCESSIBILITY CODE 803.3
 DOOR SWING. DOORS SHALL NOT SWING INTO THE ROOM UNLESS
 A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH 305.3 IS
 PROVIDED BEYOND THE ARC OF THE DOOR SWING.
  
 B) PROVISO: SHEET A2-1 NOR A6-2 PROVIDE COMPLIANCE WITH
 2010 FLORIDA ACCESSIBILITY CODE DRESSING ROOMS 803.4
 BENCHES. A BENCH COMPLYING WITH 903 SHALL BE PROVIDED
 WITHIN THE ROOM. 903.4 BACK SUPPORT. THE BENCH SHALL
 PROVIDE FOR BACK SUPPORT OR SHALL BE AFFIXED TO A WALL.
 BACK SUPPORT SHALL BE 42 INCHES (1065 MM) LONG MINIMUM
 AND SHALL EXTEND FROM A POINT 2 INCHES (51 MM) MAXIMUM
 ABOVE THE SEAT SURFACE TO A POINT 18 INCHES (455 MM)
 MINIMUM ABOVE THE SEAT SURFACE. BACK SUPPORT SHALL BE
 21/2 INCHES (64 MM) MAXIMUM FROM THE REAR EDGE OF THE
 SEAT MEASURED HORIZONTALLY.
  
 NOTE SPECIFICATION SHEETS SP01 - SP15 ARE NOT PART OF
 THE PLAN REVIEW.
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2013-09-24 Cont ID  
Sent By dharvey Date 2013-09-24 Time 13:56 Rev Time 0.00
Received By dharvey Date 2013-09-24 Time 13:56 Sent To  
Notes
2013-09-24 13:56:47RL

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2013-08-05 Cont ID  
Sent By dharvey Date 2013-08-05 Time 15:14 Rev Time 0.00
Received By dharvey Date 2013-08-05 Time 12:15 Sent To  
Notes
2013-08-05 15:14:45PROVIDE ARC FLASH WARNING LABELS PER 110.16
 TIMERS TO HAVE BACKUP PROTECTION PER FBC-EC 505.2.4
 VOLTAGE DROP CALCULATIONS TO MEET THE REQUIRMENTS OF
 FBC-EC 505.7.3
 WHAT PROVIDES THE ACTIVATION OF BL1 IN THE MANAGERS
 OFFIE? IT APPEARS TO BE ACTIVATED ALL THE TIME
 LIGHTING SCENES, SEQUENCING AND CONTROLS TO MEET THE
 REQUIREMENTS OF FBC-EC 505.2
 PROVIDE LIGHTING POWER DENSITY COMPLIANCE CERTICATION
 ON ELECTRICAL PLANS PER FBC-EC 505.503
 ALL CABLES IN SLAB AND UNDERGROUND TO BE LISTED FOR WET
 LOCATIONS, INCLUDING POS, DATA, PHONE, AUDIO, ETC.
 SEPARATE PERMITS WILL BE REQUIRED FOR LOW VOLTAGE,
 BURGLAR, AUDIO, POS, EAS, AUDIO, ETC.
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2013-07-25 Cont ID  
Sent By scaldero Date 2013-07-25 Time 14:33 Rev Time 0.00
Received By scaldero Date 2013-07-25 Time 14:33 Sent To  
Notes
2013-07-25 14:35:38PERMIT #13070388
 MASTER #
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING
 DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A
 FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN
 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE
 PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST
 BE SUBMITTED BY EMAIL ([email protected])
 ([email protected]) OR IN WRITING (FAX: 561-804-4774) AND
 APPROVED BY THE OFFICE OF THE FIRE MARSHAL LOCATED AT
 500 NORTH DIXIE HIGHWAY.
  
 ENTRY DOORS: THUMB-TURN LOCK TO BE EQUIPPED WITH A
 LOCK/UNLOCK INDICATOR.
  
 EACH FIRE BARRIER SHALL BE PERMANENTLY IDENTIFIED WITH
 SIGNS OR STENCILING READING FIRE BARRIER-PROTECT ALL
 OPENINGS. CHARACTERS SHALL BE AT LEAST 4-INCHES IN
 HEIGHT AND HALF-INCH IN WIDTH. IDENTIFICATION SHALL BE
 SPACED NOT MORE THAN 15 FEET ON CENTER.
  
 AN APPROVED WRITTEN EMERGENCY PLAN FOR THE EMERGENCY
 EGRESS OF OCCUPANTS IS REQUIRED PRIOR TO OCCUPANCY. ALL
 EMPLOYEES SHALL BE INSTRUCTED AND PERIODICALLY DRILLED
 WITH RESPECT TO THEIR DUTIES UNDER THE PLAN.
  
 EMPLOYEES SHALL BE PERIODICALLY TRAINED OR INSTRUCTED
 IN THE USE OF PORTABLE FIRE EXTINGUISHERS.
  
 SUB-PERMITS REQUIRED FOR ALL WORK DONE RELATED TO THE
 FIRE ALARM AND SPRINKLER SYSTEM.
  
 SUE ELLEN CALDERON
 FIRE INSPECTOR & INVESTIGATOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 804-4751

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2013-09-24 Time   Rev Time 0.00
Received By rregueir Date 2013-09-12 Time 08:02 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2013-08-28 Time   Rev Time 0.00
Received By rregueir Date 2013-07-11 Time 15:04 Sent To  
Notes
2013-07-18 15:05:08DIGITAL

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2013-08-28 Cont ID  
Sent By rregueir Date 2013-08-28 Time 10:30 Rev Time 0.00
Received By rregueir Date 2013-08-28 Time 10:30 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2013-07-22 Cont ID  
Sent By lwagner Date 2013-07-22 Time 15:22 Rev Time 0.00
Received By lwagner Date 2013-07-22 Time 15:21 Sent To  
Notes
2013-07-22 15:24:01***PROVISO***
 CONDENSATE SHALL NOT DRAIN TO MOP SINK.
 UTILITIES ORD. SEC. 90-126 (B) (5). PROHIBITIONS AND
 LIMITATIONS OF DISCHARGE.
 STORMWATER, SURFACE WATER, GROUNDWATER, ARTESIAN WELL
 WATER, ROOF RUNOFF, SUBSURFACE DRAINAGE, SWIMMING POOL
 DISCHARGES, UNCONTAMINATED COOLING WATER, UNPOLLUTED
 INDUSTRIAL PROCESS WATERS, AIR CONDITIONING CONDENSATE,
 UNLESS SPECIFICALLY AUTHORIZED BY THE CITY IN WRITING.
  
  

Review Stop POLICE POLICE
Rev No 2 Status N Date 2013-11-20 Cont ID  
Sent By rregueir Date 2013-11-20 Time 13:22 Rev Time 0.00
Received By rregueir Date 2013-11-20 Time 13:22 Sent To  
Notes
2013-11-20 13:23:17OK TO ISSUE PER ROBERT BROWN

Review Stop POLICE POLICE
Rev No 1 Status F Date   Cont ID  
Sent By   Date 2013-08-21 Time   Rev Time 0.00
Received By ktucker Date 2013-08-21 Time 10:38 Sent To  
Notes
2013-08-21 10:39:22(1) A FULLY FUNCTIONING AND OPERATIONAL CCTV SYSTEM
 CAPABLE OF RECORDING AND RETRIEVING ON SITE, AN
 IDENTIFIABLE IMAGE TO ASSIST IN OFFENDER IDENTIFICATION
 AND APPREHENSION.
 (2) ADDITIONAL CAMERA COVERAGE: (A) IN THE BACK OF
 HOUSE FACING THE STORE ROOM ENTRY DOOR, (B) THE HALLWAY
 THAT LEADS TO REAR DOOR SHOULD HAVE AN ADDITIONAL
 CAMERA FACING THE ENTRY FROM THE SALES AREA INTO THE
 HALLWAY (C) CAMERA BEHIND THE REGISTER, LOW FOR FACIAL
 RECOGNITION.
 (3) AN ADDITIONAL MONITOR FOR THE SYSTEM SHOULD BE
 PLACED EMPLOYEE BREAK ROOM
 (4) SILENT PANIC ALARM UNDER EACH REGISTER, IN THE
 MANAGER?S OFFICE AND ONE IN THE BACK STORAGE AREA
 (5) ACCESS CONTROL ON ALL 3 DOORS THAT LEAD INTO THE
 BACK OF HOUSE WITH A VIEW FINDER IN THE EACH DOOR,
 ALERT SENSOR WHEN THE DOORS OPEN. VIEW FINDER IN THE
 REAR SERVICE DOOR.
 (6) A SECURED DROP SAFE OR CASH MANAGEMENT DEVICE FOR
 RESTRICTED ACCESS TO MONEY/CASH RECEIPTS AT THE
 REGISTER AND A SECURED DROP SAFE OR CASH MANAGEMENT
 DEVICE IN THE STORAGE AREA.
 (7) SECURE THE REGISTER TO THE COUNTER
 (8) HEIGHT MARKERS AT THE ENTRANCE AND EXITS WHICH
 DISPLAY HEIGHT MEASURES.
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2013-11-20 Cont ID  
Sent By rregueir Date 2013-11-13 Time 13:22 Rev Time 0.00
Received By rregueir Date 2013-11-13 Time 13:22 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2013-07-26 Cont ID  
Sent By eschneid Date 2013-07-26 Time 16:40 Rev Time 2.00
Received By eschneid Date 2013-07-26 Time 14:27 Sent To  
Notes
2013-07-26 16:43:43PASSED
  
 1) EXTERIOR SIGNS AND AWNINGS REQUIRE SEPARATE PERMITS
 WITH PLANS.
  
 2) PLEASE NOTE: THE 12.5 TON RTU SHOWN ON THE LANDLORD
 PERMIT FOR THIS BUILDING ARE NOT CURRENTLY APPROVED.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
2013-07-22 10:52:257/22/13