Plan Review Details - Permit 13070148
Plan Review Stops For Permit 13070148
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2013-07-11 Cont ID  
Sent By dharvey Date 2013-07-11 Time 15:02 Rev Time 0.00
Received By dharvey Date 2013-07-11 Time 15:00 Sent To  
Notes
2013-07-11 15:02:16BY RL

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2013-11-26 Cont ID  
Sent By skennedy Date 2013-11-26 Time 16:21 Rev Time 0.00
Received By skennedy Date 2013-11-26 Time 16:21 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2013-11-14 Cont ID  
Sent By skennedy Date 2013-11-14 Time 15:36 Rev Time 0.00
Received By skennedy Date 2013-11-14 Time 15:36 Sent To  
Notes
2013-11-14 15:37:48ELECTRICAL COMMENTS OF 7/11/13 WERE NOT ADDRESSED IN
 THE RESUBMITTAL.
 STEVEN KENNEDY
 (561) 805-6710
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2013-07-11 Cont ID  
Sent By dharvey Date 2013-07-11 Time 12:28 Rev Time 0.00
Received By dharvey Date 2013-07-11 Time 12:22 Sent To B
Notes
2013-07-11 12:28:1213070148
 1401 FORUM WAY
 MONUMENT SIGN
  
 PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING
 REVIEW COMMENTS.
  
 PROVIDE ELECTRICAL DETAIL SHOWING REQUIRED ELECTRICAL
 DISCONNECTS AND CIRCUIT SIZE. DISCONNECTS ARE REQUIRED
 WITHIN SIGHT OF THE SIGN FACE AND SIGN CONTROLLER. NEC
 600.6
  
 VERIFY AND INDICATE ON THE PLANS THAT THE SIGN HAS A
 LISTING BY A NATIONALLY RECOGNIZED TESTING LABORATORY.
 NEC 110.3, 600.3
  
 ROBERT LECKY
 ELECTRICAL PLANS REVIEW
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2013-11-26 Cont ID  
Sent By skennedy Date 2013-11-26 Time 16:22 Rev Time 0.00
Received By skennedy Date 2013-11-26 Time 16:22 Sent To  
Notes
2013-11-26 14:22:37INCOMING SENT TO S KENNEDY DESK. JW

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-11-14 Cont ID  
Sent By skennedy Date 2013-11-14 Time 15:42 Rev Time 0.00
Received By skennedy Date 2013-11-05 Time 13:26 Sent To  
Notes
2013-11-06 13:26:16SENT TO ZONING BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-07-11 Cont ID  
Sent By dharvey Date 2013-07-11 Time 15:02 Rev Time 0.00
Received By dharvey Date 2013-07-03 Time 12:58 Sent To  
Notes
2013-07-03 12:59:17ROUTED TO ZONING

Review Stop Z ZONING
Rev No 2 Status P Date 2013-11-07 Cont ID  
Sent By llouie Date 2013-11-07 Time 11:14 Rev Time 0.00
Received By llouie Date 2013-11-07 Time 11:14 Sent To E
Notes
2013-11-07 11:21:33PASSED.
  
 MINOR PD AMENDMENT APPROVAL GRANTED ON 10/29/13.

Review Stop Z ZONING
Rev No 1 Status F Date 2013-07-07 Cont ID  
Sent By jroach Date 2013-07-07 Time 16:04 Rev Time 0.00
Received By jroach Date 2013-07-07 Time 16:04 Sent To E
Notes
2013-07-07 16:04:20ZONING PLAN REVIEW
 ___________________________________________
  
 DATE OF REVIEW: 07.07.2013
 PERMIT NO.: 13070148
 ADDRESS: 1401 FORUM WAY
 CONTRACTOR/CONTACT: NICOLE SULLIVAN
 TELEPHONE NO.: 954.923.3081
 SCOPE OF REVIEW: NEW ILLUMINATED MONUMENT SIGN
 ___________________________________________
  
 REVIEW STATUS: FAILED
 ___________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. PRIOR TO THE ISSUANCE OF A BUILDING PERMIT, A MINOR
 AMENDMENT TO THE COMMERCIAL PLANNED DEVELOPMENT (CPD)
 SHALL BE SUBMITTED TO AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT ? PLANNING DIVISION. PLEASE CONTACT
 ME FOR THE APPLICATION.
  
 2. PLEASE NOTE THE PROPOSED SETBACK FROM THE PROPERTY
 LINE TO THE CLOSEST POINT OF THE SIGN. SIGNS SHALL BE A
 MINIMUM OF FIVE (5) FEET FROM THE PUBLIC RIGHT-OF-WAY.
  
 3. PLEASE PROVIDE INFORMATION PERTAINING TO THE OTHER
 FREESTANDING SIGNS ON THE PROPERTY. I BELIEVE THERE ARE
 TWO (2) OTHER SIGNS, ONE IS LOCATED AT THE CORNER OF
 FORUM WAY AND FORUM PLACE, THE OTHER IS LOCATED AT THE
 ENTRANCE OFF OF FORUM PLACE. PLEASE INDICATE THE SQUARE
 FOOTAGE OF SIGNAGE (IF THE SIGN HAS MULTIPLE FACES, BE
 SURE TO INCLUDE THE SQUARE FOOTAGE OF ALL FACES).
  
 4. PLEASE CLARIFY WHETHER OR NOT THE PROPOSED SIGN IS
 DOUBLE-SIDE OR NOT.
  
 5. PLEASE PROVIDE TWO (2) COPIES OF A CURRENT AND
 ACCURATE SURVEY.
 ___________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN ROACH, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 PHONE: 561.822.1448
 FAX: 561.822.1460
  
 EMAIL: [email protected]
  
 WWW.WPB.ORG
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved