Plan Review Details - Permit 13070121
Plan Review Stops For Permit 13070121
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-09-18 Cont ID  
Sent By jgomez Date 2013-09-18 Time 17:47 Rev Time 0.00
Received By jgomez Date 2013-09-18 Time 17:47 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-07-23 Cont ID  
Sent By JGOMEZ Date 2013-07-23 Time 15:41 Rev Time 0.00
Received By jgomez Date 2013-07-23 Time 15:41 Sent To  
Notes
2013-07-23 15:41:54REVISION BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 (1)- BUILDING REVIEW WAS APPROVED BACK IN 12/14/12 WITH
 A PROVISO (SEE COPY OF PROVISO BELOW). REVISED PLANS
 SUBMITTED DON'T ADDRESS THESE ITEMS. NEED TO ADDRESS
 THEM NOW BEFORE ANY WORK IS DONE. SEC. 107.2.1 CITY
 AMENDMENTS TO FBC.
  
 "BUILDING REVIEW APPROVED WITH PROVISO:
 1- SHEET 1.2:
 A) UTILITY AREA NEW OUTDOOR STEPS: (1) PROVIDE COMPLETE
 HANDRAILS DETAILS AND SPECIFICATIONS SHOWING COMPLIANCE
 WITH LIVE LOAD ON TABLE R301.5 AND SEC. R311.7.7 OF
 2010 FBC-RESIDENTIAL. ENGINEER PLANS ONLY SAY NEW
 HANDRAIL DESIGNED BY OTHERS. NO INFORMATION WAS
 PROVIDED FOR REVIEW.
  
 B) NEW STEPS ON REAR SHOWS TREAD SIZE AS 8". MINIMUM
 TREAD SIZE IS 10". SEE SEC. R311.7.4.2 OF 2010
 FBC-RESIDENTIAL AND REVISE AS REQUIRED.
  
  
 ***REVISION COMMENTS:
 (2) NEED TO ADD THE VALUE THAT REFLECTS THE ADDITIONAL
 WORK SHOWN ON PLANS. REVISED PLANS SHOW NEW FLOOR
 FRAMING AND NEW ROOF FRAMING. SEC. 109.3 CITY
 AMENDMENTS TO FBC.
  
 (3) PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR THE NEW SIMPSON STRUCTURAL CONNECTORS
 SPECIFIED ON REVISED PLANS AND DETAILS.
 ***NOTE: PROVIDE ONLY THE PRODUCT APPROVAL COVER PAGE
 AND PAGE SHOWING THE SPECIFIED CONNECTOR
  
 ***NOTE: IF DOING ANY ROOFING WORK, THEN SEPARATE
 ROOFING PERMIT IS REQUIRED. ROOFING CONTRACTOR IS
 REQUIRED AND PROVIDE COMPLETE INFORMATION FOR SUCH
 PERMIT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2013-09-09 Cont ID  
Sent By dharvey Date 2013-09-09 Time 15:12 Rev Time 0.00
Received By dharvey Date 2013-09-09 Time 15:12 Sent To  
Notes
2013-09-09 15:13:05SECOND REVIEW - 9-9-13
  
 CORRECTIONS MADE AND DRAWINGS NOTED......

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2013-08-02 Cont ID  
Sent By RLECKY Date 2013-08-02 Time 15:10 Rev Time 0.00
Received By dharvey Date 2013-08-02 Time 14:31 Sent To  
Notes
2013-08-02 15:10:24LOCATE SMOKE DETECTORS FOR MOST EFFECTIVE COVERAGE IN
 THE BEDROOMS AND FOR EARLY DETECTION 110.3
 PROVIDE CO DETECTOR PER FBC -R 916.1
 PROVIDE INTERSYSTEM BONDING POINT 250.94
 PROVIDE FOR BONDING OF INTERIOR METAL GAS PIPE
 NEW LOAD BEING ADDED (AC), PROVIDE LOAD CALCULATION FOR
 RECORD TO INDICATE EXISTING SERVICE IS OF SUFFICIENT
 SIZE
 ARC FAULT BREAKERS REQUIRED AND TAMPERPROOF RECEPTACLES
 FOR ANY NEW OR REMODELED ITEMS 210.12, 406.11
  

Review Stop HIST HISTORICAL
Rev No 1 Status N Date 2013-07-18 Cont ID  
Sent By fmittner Date 2013-07-18 Time 09:50 Rev Time 0.00
Received By fmittner Date 2013-07-18 Time 09:49 Sent To  
Notes
2013-07-10 15:12:377/10/13

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-09-18 Cont ID  
Sent By jgomez Date 2013-09-18 Time 18:13 Rev Time 0.00
Received By jgomez Date 2013-08-13 Time 10:45 Sent To  
Notes
2013-08-15 10:45:45RESUBMITTAL SENT TO R9 SHELF FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-08-05 Cont ID  
Sent By rmcdouga Date 2013-08-05 Time 08:26 Rev Time 0.00
Received By rmcdouga Date 2013-07-03 Time 16:02 Sent To  
Notes
2013-07-08 16:03:14SENT TO R7 SHELF FOR REVIEW. JG.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2013-09-18 Cont ID  
Sent By jgomez Date 2013-09-18 Time 18:00 Rev Time 0.00
Received By jgomez Date 2013-09-18 Time 18:00 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2013-07-23 Cont ID  
Sent By jgomez Date 2013-07-23 Time 17:24 Rev Time 0.00
Received By jgomez Date 2013-07-23 Time 17:24 Sent To  
Notes
2013-07-23 17:30:54RESIDENTIAL (R3) REVISION, MECHANICAL REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- REVISED M.1 PLAN DOESN'T SHOW TRANSFER DUCT IN THE
 AIR CONDITIONED PORCH AS REQUIRED BY SEC. M1602.4 OF
 2010 FBC-RESIDENTIAL. REVISE AS REQUIRED. ORIGINAL PLAN
 WAS APPROVED WITH THE TRANSFER DUCT SHOWN IN THIS AREA.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop P PLUMBING
Rev No 2 Status P Date 2013-09-18 Cont ID  
Sent By jgomez Date 2013-09-18 Time 18:13 Rev Time 0.00
Received By jgomez Date 2013-09-18 Time 18:13 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2013-07-23 Cont ID  
Sent By JGOMEZ Date 2013-07-23 Time 17:31 Rev Time 0.00
Received By jgomez Date 2013-07-23 Time 17:30 Sent To  
Notes
2013-07-23 17:37:18RESIDENTIAL (R3) REVISION, PLUMBING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- ALL GAS WORK IS REQUIRED TO BE SUBMITTED UNDER A
 SEPARATE GAS PERMIT. CONTRACTOR TO PROVIDE COMPLETE
 INFORMATION UNDER A SEPARATE GAS PERMIT. SEC. 105.1
 CITY AMENDMENTS TO FBC.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop Z ZONING
Rev No 1 Status P Date 2013-07-18 Cont ID  
Sent By fmittner Date 2013-07-18 Time 09:50 Rev Time 0.00
Received By fmittner Date 2013-07-18 Time 09:50 Sent To  
Notes
2013-07-18 09:50:22R-7