Plan Review Details - Permit 13061001
| Plan Review Stops For Permit 13061001 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2013-08-31 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-08-31 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-08-31 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2013-08-31 14:29:26 | ***COURTESY REVIEWS WERE PERFORMED VIA EMAIL** | | | | | | EMAIL FROM 8/31: | | | | | | BEFORE I DO ANOTHER COURTESY REVIEW, PLEASE REFER TO MY | | | COMMENT LIST, AND THEN CIRCLE OR HIGHLIGHT ON THE TEST | | | YOU WISH FOR ME TO REVIEW THE TEST STANDARD USED. THERE | | | SHOULD BE A TOTAL OF 3 (IIC, STC, FLAME SPREAD). | | | | | | IF YOU CANNOT FIND THE TEST CIRCLED REFERENCED IN THE | | | COMMENT LIST, THEY'D NEED TO SUBMIT A REQUEST FOR | | | ALTERNATIVE MATERIALS AND METHODS TO PROVIDE DATA TO | | | JUSTIFY WHY THEY ELECTED TO USE A DIFFERENT TEST, OR A | | | DIFFERENT METHOD, OR PROVIDE DATA/ENGINEERING TO SHOW | | | WHY THEY DO NOT NEED TO PERFORM THE TEST PRESCRIBED BY | | | THE FBC AND IBC (THEREFORE A NATIONAL REQUIREMENT | | | ANYWHERE THAT USES THE ICC AS BASE CODE). ALSO CHECK | | | THAT NONE OF THE TESTS INCLUDE A SUSPENDED DRYWALL | | | CEILING. | | | | | | I STARTED TO LOOK AT THE DOCUMENTS - THE FIRST HAD A | | | SUSPENDED CEILING. THE SECOND DID NOT MEET THE | | | REQUIREMENTS OF THE STANDARDS OF THE TEST. PLEASE TAKE | | | THE TIME TO READ THE TEST REPORTS BEFORE SENDING. BY | | | NOW YOU SHOULD BE AN EXPERT! | | | | | | AFTER YOU CONFIRM THAT, TO THE BEST OF YOUR KNOWLEDGE, | | | THE PRODUCT MEETS THE REQUIREMENTS OF THE FBC, PLEASE | | | FEEL FREE TO SEND TO ME. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-07-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-07-05 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-07-05 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2013-07-05 15:28:05 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. | | | IF A SUSPENDED CEILING WAS USED AS A PART OF THE TEST, | | | PROVIDE INFORMATION AS TO HOW IT HAS BEEN DETERMINED | | | THAT THIS CONDITION CURRENTLY EXISTS AND HOW IT CAN BE | | | GUARANTEED THAT THE CONDITIONS IN THE UNIT BELOW WILL | | | NOT BE ALTERED. PROVIDE COPIES OF TEST REPORT. | | | | | | 2. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | | ASTM E 492. IF A SUSPENDED CEILING WAS USED AS A PART | | | OF THE TEST, PROVIDE INFORMATION AS TO HOW IT HAS BEEN | | | DETERMINED THAT THIS CONDITION CURRENTLY EXISTS AND HOW | | | IT CAN BE GUARANTEED THAT THE CONDITIONS IN THE UNIT | | | BELOW WILL NOT BE ALTERED. PROVIDE COPY OF TEST REPORT. | | | | | | 3. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | | | SEE 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM | | | E 84 OR UL 723. | | | | | | 4. THIS WORK IS NOT WITHIN THE SCOPE OF A RESIDENTIAL | | | CONTRACTOR LICENSE. | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-07-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-07-05 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-06-26 |
Time |
07:15 |
Sent To |
|
|
| Notes |
| 2013-06-27 07:16:23 | SENT TO BLDG. UNDER $5000 BOX. |
|
|
|