| 2013-07-11 13:01:24 | BUILDING PLAN REVIEW |
| | PERMIT: 13060989 |
| | ADD: 1801 S FLAGLER DR # 802 |
| | CONT:MARYJULECONSTRUCTION |
| | TEL: (561)386-6032 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 1ST REVIEW |
| | DATE: JULY 11/ 2013 |
| | ACTION: PROVISO |
| | BUILDING APPROVED WITH EXCEPTION! |
| | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE |
| | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1) PLANS WILL REQUIRE A DETAIL FOR THE CREATION OF A |
| | NEW DROPPED CEILING AND SOFFITS. THE DETAIL SHALL |
| | INCLUDE, FRAMING MATERIALS, SIZE, GAUGE, SPACING OF |
| | FRAMING, SPAN OF CEILING BEING HUNG, IF STIFF BACKS ARE |
| | REQUIRED? PROVIDE DETAIL OF HOW THE TRAY DROPPED CEILNG |
| | WILL BE ATTACHED TO THE DECK ABOVE, TYPE OF FASTENER, |
| | AND LENGTH, ALSO INCLUDE TYPE OF CEILING FINISH AND |
| | THICKNESS OF MATERIAL. WILL THE DROPPED CEILING ABOVE |
| | BE CONSIDERED A PLENUM? |
| | 2010 WPB ADMINISTRATIVE CODE 107.2.1 INFORMATION ON |
| | CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE |
| | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. |
| | ELECTRONIC MEDIA DOCUMENTS SHALL BE SUBMITTED WHEN |
| | APPROVED BY THE BUILDING OFFICIAL. CONSTRUCTION |
| | DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE |
| | THE LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED |
| | AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE |
| | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, |
| | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING |
| | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL |
| | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, |
| | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS |
| | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. |
| | |
| | 2) PLANS SHOW A KITCHEN WALL BEING MOVED, NEW FLOOR |
| | AREA IS GOING TO BE REVEALED. IF THE FLOOR FINISH OF |
| | THE KITCHEN IS NOT BEING REMOVED, THIS IS CONSIDERED A |
| | REPAIR AND NO FLOOR INSULATION IS NEEDED. IF THE |
| | KITCHEN FLOOR IS REMOVED THEN COMPLIANCE WITH THE |
| | FOLLOWING SECTIONS WILL NEED TO BE REQUIRED: |
| | |
| | 2A) FBC-B 2010 1207.3 STRUCTURE-BORNE SOUND. |
| | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR |
| | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA |
| | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION |
| | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD |
| | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. |
| | 2B) FBC-B 2010 603.2 EXCEPTION (1) TILE FLOORING |
| | FLOOR INSULATION PLACED BETWEEN TWO LAYERS OF |
| | NONCOMBUSTIBLE MATERIALS WITHOUT AN INTERVENING |
| | AIRSPACE SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX |
| | OF NOT MORE THAN 100. |
| | |
| | 2C) FBC-B 2010 603.2 EXCEPTION 2 WOOD FLOORS |
| | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID |
| | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED |
| | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. |
| | |
| | FBC-B 2010 |