| Plan Review Stops For Permit 13060868 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2013-12-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-12-17 |
Time |
18:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-12-17 |
Time |
18:19 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2013-11-25 |
|
|
Cont ID |
|
| Sent By |
S Hill |
Date |
2013-11-25 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-11-25 |
Time |
12:44 |
Sent To |
|
|
| Notes |
| 2013-11-25 16:49:04 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. OK. | | | | | | 2. FBC 2010 EXISTING BUILDING 912.4.1, FBC 2010 | | | BUILDING 1031.2, PANIC AND FIRE EXIT HARDWARE REQUIRED | | | WHERE THE MEANS OF EGRESS DOOR SERVES AN OCCUPANT LOAD | | | GREATER THAN 100. SEE ALSO COMMENT 3; OCCUPANT LOAD. | | | REVISE PLAN TO SHOW LOCATIONS REQUIRED, IF ANY. | | | | | | 2ND REVIEW, REQUIREMENTS CANNOT BE DETERMINED DUE TO | | | LACK OF INFORMATION, SEE ITEM 3. | | | | | | 3RD REVIEW, PLANS INDICATE THAT ALL DOORS WILL HAVE | | | PANIC DEVICES. PLANS ALSO HAVE A STATEMENT THAT ALL | | | INFORMATION WAS PROVIDED BY OWNER. DESIGNER OF RECORD | | | TO DETERMINE WHETHER EXTERIOR DOORS HAVE PANIC DEVICES | | | AND TO INCLUDE IN SCOPE OF WORK IF THEY ARE NEEDED. AS | | | THEY ARE COMPONENTS AND CLADDING, PRODUCT APPROVALS | | | REQUIRED. | | | | | | 3. OK | | | | | | 4. OK | | | | | | 5. FBC 2010 EXISTING BUILDING 912.5, HEIGHT AND AREA TO | | | COMPLY WITH FBC 2010 BUILDING TABLE 503 FOR BUILDING | | | HEIGHT & AREA. | | | | | | 2ND REVIEW, RESPONSE LETTER STATES THIS IS COMPLETED. | | | IT IS NOT CLEAR HOW THIS WAS ADDRESSED AS NO | | | INFORMATION ABOUT THE EXISTING BUILDING WAS PROVIDED. | | | | | | 3RD REVIEW, PLEASE ADDRESS. | | | | | | 6. OK | | | | | | NEW COMMENT: | | | | | | PLEASE NOTE THAT THIS IS A CHANGE OF OCCUPANCY AS WELL | | | AS A LEVEL 2 ALTERATION. PLEASE INCLUDE THIS | | | INFORMATION ON THE PLAN. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2013-08-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-08-12 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-08-12 |
Time |
11:33 |
Sent To |
|
|
| Notes |
| 2013-08-12 11:40:05 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. FBC 2010 EXISTING BUILDING 912.2.2, FBC 2010 | | | BUILDING 907.2.3, FIRE ALARM REQUIRED. | | | | | | 2ND REVIEW, PLEASE ADVISE WHEN THIS IS ISSUED. | | | | | | 2. FBC 2010 EXISTING BUILDING 912.4.1, FBC 2010 | | | BUILDING 1031.2, PANIC AND FIRE EXIT HARDWARE REQUIRED | | | WHERE THE MEANS OF EGRESS DOOR SERVES AN OCCUPANT LOAD | | | GREATER THAN 100. SEE ALSO COMMENT 3; OCCUPANT LOAD. | | | REVISE PLAN TO SHOW LOCATIONS REQUIRED, IF ANY. | | | | | | 2ND REVIEW, REQUIREMENTS CANNOT BE DETERMINED DUE TO | | | LACK OF INFORMATION, SEE ITEM 3. | | | | | | 3. FBC 2010 EXISTING BUILDING 912.4.1, FBC 2010 | | | BUILDING 1004.1.1, LABEL EACH ROOM WITH OCCUPANCY | | | CLASSIFICATION AND OCCUPANT LOAD FOR EACH ROOM. | | | ALTHOUGH THE SCHOOL BOARD HAS DETERMINED THAT YOU CAN | | | HAVE A MAXIMUM OF 150 STUDENTS, THE FLORIDA BUILDING | | | CODE REQUIRES EXITING IN COMPLIANCE WITH FBC 2010 TABLE | | | 1004. | | | | | | NOT ADDRESSED. RESPONSE LETTER STATES THAT PLAN WAS | | | REVISED. PLAN SHOWS RATIOS SUCH AS 1:10, 1:18. THIS IS | | | NOT AN OCCUPANT LOAD. SEE FBC TABLE 1004. EACH ROOM | | | SHOULD STATE OCCUPANT LOAD (EITHER DESIGN LOAD OR | | | OCCUPANT LOAD FROM TABLE 1004, WHICHEVER IS GREATER). | | | | | | 4. OK | | | | | | 5. FBC 2010 EXISTING BUILDING 912.5, HEIGHT AND AREA TO | | | COMPLY WITH FBC 2010 BUILDING TABLE 503 FOR BUILDING | | | HEIGHT & AREA. | | | | | | 2ND REVIEW, RESPONSE LETTER STATES THIS IS COMPLETED. | | | IT IS NOT CLEAR HOW THIS WAS ADDRESSED AS NO | | | INFORMATION ABOUT THE EXISTING BUILDING WAS PROVIDED. | | | | | | 6. IMPACT FEE ASSESSMENT REQUIRED BY PALM BEACH COUNTY. | | | 561-233-5025 FOR MORE INFORMATION. PROVIDE STAMPED PLAN | | | AND RECEIPT, IF APPLICABLE. | | | | | | 2ND REVIEW, NOT ADDRESSED. THIS MAY BE DONE AT THE END | | | OF PLAN REVIEW PROCESS BUT MUST BE DONE PRIOR TO | | | ISSUANCE OF A PERMIT. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-07-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-07-01 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-07-01 |
Time |
11:56 |
Sent To |
|
|
| Notes |
| 2013-07-01 12:39:45 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. FBC 2010 EXISTING BUILDING 912.2.2, FBC 2010 | | | BUILDING 907.2.3, FIRE ALARM REQUIRED. | | | | | | 2. FBC 2010 EXISTING BUILDING 912.4.1, FBC 2010 | | | BUILDING 1031.2, PANIC AND FIRE EXIT HARDWARE REQUIRED | | | WHERE THE MEANS OF EGRESS DOOR SERVES AN OCCUPANT LOAD | | | GREATER THAN 100. SEE ALSO COMMENT 3; OCCUPANT LOAD. | | | REVISE PLAN TO SHOW LOCATIONS REQUIRED, IF ANY. | | | | | | 3. FBC 2010 EXISTING BUILDING 912.4.1, FBC 2010 | | | BUILDING 1004.1.1, LABEL EACH ROOM WITH OCCUPANCY | | | CLASSIFICATION AND OCCUPANT LOAD FOR EACH ROOM. | | | ALTHOUGH THE SCHOOL BOARD HAS DETERMINED THAT YOU CAN | | | HAVE A MAXIMUM OF 150 STUDENTS, THE FLORIDA BUILDING | | | CODE REQUIRES EXITING IN COMPLIANCE WITH FBC 2010 TABLE | | | 1004. | | | | | | 4. PLEASE REVISE PLAN TO NOTE WHETHER THIS WILL BE USED | | | FOR CLASSROOM/SCHOOL ONLY, OR ALSO FOR DAY CARE FBC | | | 2010 BUILDING 1037. | | | | | | 5. FBC 2010 EXISTING BUILDING 912.5, HEIGHT AND AREA TO | | | COMPLY WITH FBC 2010 BUILDING TABLE 503 FOR BUILDING | | | HEIGHT & AREA. | | | | | | 6. IMPACT FEE ASSESSMENT REQUIRED BY PALM BEACH COUNTY. | | | 561-233-5025 FOR MORE INFORMATION. PROVIDE STAMPED PLAN | | | AND RECEIPT, IF APPLICABLE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2013-12-02 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-12-02 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-12-02 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2013-12-02 13:49:41 | ILLUMINATION LEVEL VERIFICATION NOT REQUIRED PER ROBERT | | | BROWN. REQUIREMENT APPLIES TO PUBLIC SCHOOLS AND | | | CHARTER SCHOOLS DO NOT NEED TO COMPLY. DH | | 2013-10-29 11:34:17 | NEW PLANS SUBMITTED. JG. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2013-08-06 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-08-05 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-08-05 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2013-08-05 15:33:27 | SEPERATE FIRE ALARM PERMIT IS REQUIRED | | | SEPARATE PERMITS ARE REQUIRE FOR DATA, LOW VOLTAGE, | | | AUDIO, ACCESS AND OTHER SYSTEMS | | | ALL PREVIOUS ITEMS HAVE BEEN ADDRESSED EXCEPT | | | ILLUMINATION LEVEL VERIFICATION | | | PROVIDE CERTIFICATION OF ILLUMANATION LEVEL AND | | | PHOTOMETRIC CHART FOR RECORD PRIOR TO FINAL INSPECTION |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2013-06-27 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-06-27 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-06-27 |
Time |
11:07 |
Sent To |
FIRE |
|
| Notes |
| 2013-06-27 11:10:33 | 13060868 | | | 901 NORTH POINT PKWY | | | CHANGE OF USE TO EDUCATIONAL | | | | | | VERIFY THAT THE REQUIRED WORKING CLEARANCES AND | | | DEDICATED WORKING SPACE HAS BEEN PROVIDED FOR THE | | | ELECTRICAL EQUIPMENT AND PANEL BOARDS. NEC 110.26, | | | 240.24, 408.17 | | | | | | A FIRE ALARM SYSTEM IS REQUIRED FOR THIS FACILITY. A | | | SEPARATE PERMIT WITH PLAN AND SHOP DRAWINGS IS | | | REQUIRED. NFPA 101 15.3.4, FBC 907.2.3 | | | | | | VERIFY THE MEANS OF EGRESS HAS EMERGENCY ILLUMINATION | | | AND EXIT SIGNS. FBC 1006.2 1011.1 | | | | | | VERIFY COMPLIANCE WITH REQUIRED ILLUMINATION LEVEL, | | | UNIFORMITY, BRIGHTNESS AND GLARE IN | | | CLASSROOMS/INSTRUCTION SPACES. FBC 443.3.7 | | | | | | GFCI PROTECTION IS REQUIRED FOR ELECTRIC WATER COOLERS. | | | NEC 422.52 | | | | | | VENDING MACHINES IF PROVIDED SHALL BE PROTECTED WITH | | | GFCI?S. NEC 422.51 | | | | | | ALL RECEPTACLES LOCATED WITHIN SIX FEET OF A SINKS MUST | | | BE GFCI PROTECTED. NEC 210.8 | | | | | | NOTE: | | | SEPARATE PERMITS WITH PLANS ARE REQUIRED FOR VOICE, | | | DATA, FIRE ALARM, AND SECURITY. | | | | | | ROBERT LECKY | | | ELECTRICAL PLANS REVIEW | | | 561-805-6718 | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2013-12-18 |
|
|
Cont ID |
|
| Sent By |
rferguso |
Date |
2013-12-18 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
rferguso |
Date |
2013-12-18 |
Time |
09:33 |
Sent To |
|
|
| Notes |
| 2013-12-18 10:09:36 | 901 NORTHPOINT PARKWAY SUITE #400-404 | | | PERMIT #13060868 | | | | | | WEST PALM BEACH FIRE RESCUE PLAN REVIEW COMMENTS. | | | | | | * PLAN (APPROVED, PROVISO), ALL ITEMS LISTED ON | | | 12/12/2013'S REVIEW IS ADDRESSED. | | | | | | RONALD E. FERGUSON, ASSISTANT FIRE MARSHAL | | | BUREAU OF FIRE PREVENTION | | | WEST PALM BEACH FIRE RESCUE | | | PHONE #(561) 804-4700 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2013-12-12 |
|
|
Cont ID |
|
| Sent By |
rferguso |
Date |
2013-12-12 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
rferguso |
Date |
2013-12-12 |
Time |
11:29 |
Sent To |
M |
|
| Notes |
| 2013-12-12 11:45:30 | 901 NORTHPOINT PARKWAY, SUITE 400-404 | | | PERMIT #13060868 | | | | | | WEST PALM BEACH FIRE RESCUE PLAN REVIEW COMMENTS. | | | | | | ** BE SPECIFIC ON THE PLAN OF WHAT DOORS ARE TO BE | | | OUTFITTED WITH PANIC HARDWEAR. | | | ** NO EMERGENCY LIGHTS ARE BEING SHOWN ON THE PLANS. | | | ** SUBMIT SEPERATE PLANS FOR THE FIRE ALARM SYSTEM. | | | | | | | | | RONALD E. FERGUSON, ASSISTANT FIRE MARSHAL | | | BUREAU OF FIRE PREVENTION | | | WEST PALM BEACH FIRE RESCUE | | | PHONE #(561) 804-4700 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2013-08-09 |
|
|
Cont ID |
|
| Sent By |
rfergso |
Date |
2013-08-09 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2013-08-09 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2013-08-09 15:27:09 | PERMIT #13060868 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | PROVIDE A SCALABLE PLAN. | | | | | | STORAGE ROOMS SHALL BE SEPERATED FROM THE OTHER ROOMS | | | WITH A 1-HOUR RATED FIRE WALL AND 45-MINUTE FIRE RATED | | | DOOR. | | | | | | EXIT ACCESS CORRIDORS SHALL BE AT LEAST 6 FEET IN | | | WIDTH. | | | | | | CORRIDORS SHALL BE SEPERATED FROM OTHER AREAS WITH A | | | 1-HOUR RATED BARRIER AND A 45-MINUTE DOOR. | | | | | | AN ACCURATE AND DETAILED FURNITURE PLAN MUST BE | | | SUBMITTED. | | | | | | CLUSTER OF OFFICES EXCEEDS 10 PERCENT OF THE OVERALL | | | SPACE USED, CLASSIFYING IT AS A NON-SEPERATED MIXED USE | | | OCCUPANCY. | | | THE LARGE CLASSROOM AREA (LABELED "CAFETERIA" IN THE | | | ORIGINAL PLANS) HAS AN AREA WHICH RESULTS IN AN | | | OCCUPANT LOAD GREATER THAN 50 PERSONS, CLASSIFYING IT | | | AS AN ASSEMBLY OCCUPANCY. | | | FOR NON-SEPARATED MIXED USE OCCUPANCIES, THE MOST | | | STRINGENT FIRE AND LIFE SAFETY REQUIREMENTS OF EACH | | | OCCUPANCY SHALL APPLY TO THE BUILDING. | | | | | | PROVIDE A LIFE SAFETY PLAN SHOWING ALL OCCUPANCY TYPES, | | | OCCUPANT LOADS, FIRE RATED WALLS, EXIT SIGNS, EMERGENCY | | | LIGHTING, TRAVEL DISTANCES, COMMON PATH OF TRAVEL ETC. | | | THE LOCATIONS OF THE EXIT SIGNS AND EMERGENCY LIGHTS | | | MUST BE CLEARLY IDENTIFIED. | | | | | | PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS | | | SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE | | | TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL | | | DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET. | | | | | | ALL ROOMS SHOULD BE DESIGNATED WITH A NAME OR FUNCTION. | | | | | | | | | SUE ELLEN CALDERON | | | FIRE INSPECTOR & INVESTIGATOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 804-4751 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2013-06-28 |
|
|
Cont ID |
|
| Sent By |
rferguso |
Date |
2013-06-28 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
rferguso |
Date |
2013-06-28 |
Time |
15:28 |
Sent To |
B |
|
| Notes |
| 2013-06-28 15:59:02 | 901 NORTHPOINT PARKWAY #400-401 | | | PERMIT #13060868 | | | | | | WEST PALM BEACH FIRE RESCUE PLAN REVIEW COMMENTS. | | | | | | 1) STORAGE ROOMS SHALL BE SEPERATED FROM THE OTHER | | | ROOMS WITH A 1- HOUR FIRE - RATED WALL AND 45 - MIN. | | | FIRE RATED DOORS. | | | | | | 2) EXIT ACCESS CORRIDORS SHALL BE AT LEAST 6 - FEET IN | | | WIDTH. | | | | | | 3) CORRIDORS SHALL BE SEPERATED FROM OTHER AREAS WITH A | | | 1 - HOUR FIRE RATED BARRIER AND 45 - MIN. FIRE RATED | | | DOORS. | | | | | | 4) FURNITURE PLANS MUST BE SUBMITTED. | | | | | | 5) THE PLAN INDICATES NON - FILES SEPERATED, MIXED USE | | | OCCUPANCIES, (EDUCATION AND ASSEMBLY). THE MOST | | | STRINGENT OCCUPANTCY REQUIRMENTS APPLY. FOR EXAMPLE, AN | | | ASSEMBLY OCCUPANCY WITH 300 + PERSONS IS REQUIERED TO | | | BE PROTECTED BY AN AUTOMATIC SPRINKLER SYSTEM WHEREAS | | | EDUCATIONAL OCCUPANCIES REQUIRE A SPRINKLER SYSTEM IF | | | THE FLOOR AREA EXCEED 12,000 SQ. FT. | | | | | | 6) A LIFE SAFETY PLAN IS NEEDED SHOWING FIRE RATED | | | WALLS, EXIT SIGNS, EMERGENCY LIGHTING, FIRE ALARM | | | DEVICES, PANIC HARDWARE LOCATIONS, ETC. | | | | | | | | | | | | RONALD E. FERGUSON, ASSISTANT FIRE MARSHAL | | | BUREAU OF FIRE PREVENTIO | | | WEST PALM BEACH FIRE RESCUE | | | PHONE #(561) 804-4700 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2013-12-19 |
|
|
Cont ID |
|
| Sent By |
jlmitch |
Date |
2013-12-19 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
jlmitch |
Date |
2013-12-19 |
Time |
08:15 |
Sent To |
|
|
| Notes |
| 2013-12-17 18:19:55 | TO RF DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-12-14 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-12-14 |
Time |
07:30 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-10-28 |
Time |
11:36 |
Sent To |
|
|
| Notes |
| 2013-10-29 11:37:17 | SENT TO B2 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-08-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-08-12 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-08-05 |
Time |
12:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-07-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-07-01 |
Time |
12:40 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-06-25 |
Time |
08:53 |
Sent To |
|
|
| Notes |
| 2013-06-25 08:53:12 | TO LEW DESK | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2013-11-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-11-25 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-11-25 |
Time |
12:46 |
Sent To |
|
|
| Notes |
| 2013-11-25 12:47:10 | NO FEES DUE (CHARTER SCHOOL) | | | PALM BEACH COUNTY STAMP SHOWS 8825 SF AND $0 DUE | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2013-07-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-07-01 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-07-01 |
Time |
12:39 |
Sent To |
|
|
| Notes |
| 2013-07-01 12:40:25 | SEE BUILDING COMMENTS | | | | | | 561-233-5025 FOR IMPACT FEE INFORMATOIN |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2013-12-14 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-12-14 |
Time |
07:30 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-12-14 |
Time |
06:59 |
Sent To |
|
|
| Notes |
| 2013-12-14 07:30:35 | PASS PROVISO | | | REVISION REQUIRED WITH FRESH AIR CALCULATIONS. | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2013-08-05 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-08-05 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-08-05 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2013-08-05 14:17:30 | PLANS DENIED | | | PROVIDE FRESH AIR CALCULATIONS ON THE PLANS. | | | PER TABLE 403.3 FBC (M) 2010 | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2013-06-25 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-06-25 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-06-25 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2013-06-25 16:25:14 | PASS PROVISO | | | PROVIDE A REVISION SHOWING FRESH AIR | | | CALCULATIONS PER TABLE 403.3 MINIMUM | | | VENTILATION RATES 2010 FBC (M) | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2013-11-04 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-11-04 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-11-04 |
Time |
08:58 |
Sent To |
|
|
| Notes |
| 2013-10-29 11:34:49 | NEW SHEETS SUBMITTED. JG. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2013-08-09 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-08-09 |
Time |
07:30 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-08-09 |
Time |
07:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2013-06-27 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-06-27 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-06-27 |
Time |
08:36 |
Sent To |
|
|
| Notes |
| 2013-06-27 09:11:01 | ***PROVISO*** | | | | | | HIGH / LOW DRINKING FOUNTAIN REQUIRED |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2013-06-27 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2013-06-27 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2013-06-27 |
Time |
09:24 |
Sent To |
|
|
| Notes |
| 2013-06-27 09:25:48 | 6/27/13- APPROVED. SCHOOLS ARE PERMITTED IN BY RIGHT IN | | | NORTHPOINT. | | | | | | ANGELLA VANN | | | 561-822-1441 | | | [email protected] |
|
|