Plan Review Details - Permit 13060758
Plan Review Stops For Permit 13060758
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2013-07-05 Cont ID  
Sent By jwitmer Date 2013-07-05 Time 14:14 Rev Time 0.00
Received By jwitmer Date 2013-07-05 Time 14:14 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2013-07-05 Cont ID  
Sent By dharvey Date 2013-07-05 Time 14:27 Rev Time 0.00
Received By dharvey Date 2013-07-05 Time 14:21 Sent To  
Notes
2013-07-05 14:27:39BY RL

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2013-07-05 Cont ID  
Sent By wjolin Date 2013-07-05 Time 14:06 Rev Time 0.00
Received By wjolin Date 2013-07-05 Time 14:06 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2013-06-24 Cont ID  
Sent By lphilmor Date 2013-06-24 Time 15:33 Rev Time 0.00
Received By lphilmor Date 2013-06-24 Time 07:57 Sent To  
Notes
2013-06-24 15:33:13721 VILLAGE BLVD, STE 107
 PERMIT #13060758
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 1. NO ADDRESS PROVIDED IN THE PLAN TITLEBLOCK
 INFORMATION.
 2. PROVIDE DRAWING NOTE INDICATING ALL CONSTRUCTION AND
 DEMOLITION WORK SHALL CONFORM TO THE REQUIREMENTS OF
 NFPA 241. TRASH AND CONSTRUCTION DEBRIS SHALL BE
 REMOVED FROM THE SITE DAILY. SMOKING SHALL BE
 PROHIBITED EXCEPT IN DESIGNATED EXTERIOR AREAS. ALL
 OTHER DEMOLITION OR CONSTRUCTION AREAS SHALL HAVE "NO
 SMOKING" SIGNS POSTED. WHERE SMOKING IS PERMITTED, SAFE
 RECEPTACLES FOR SMOKING MATERIALS SHALL BE PROVIDED.
 3. PROVIDE DRAWING NOTE INDICATING, ?FIRE PROTECTION
 SYSTEMS SHALL REMAIN ACTIVE DURING DEMOLITION AND
 RENOVATION ACTIVITIES. IN THE EVENT A FIRE PROTECTION
 SYSTEM IS OUT OF SERVICE FOR MORE THAN 4-HOURS IN A
 24-HOUR PERIOD, THE BUILDING SHALL BE PLACED UNDER A
 FIRE WATCH. ALL FIRE WATCH REQUESTS MUST BE SUBMITTED
 BY EMAIL ([email protected]) OR IN WRITING (FAX:
 561-804-4774) AND APPROVED BY THE OFFICE OF THE FIRE
 MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY.?
 4. SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE
 INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER
 SYSTEM.
 5. THE INTERIOR FINISH MATERIALS FOR WALLS AND CEILINGS
 SHALL MEET THE SMOKE DEVELOPMENT (0-450) AND FLAME
 SPREAD (76-200) REQUIREMENTS FOR CLASS C INTERIOR
 FINISHES PER NFPA 101.
  
  
 LAUREN PHILMORE
 FIRE INSPECTOR II / INVESTIGATOR I
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 804-4783
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-07-05 Cont ID  
Sent By dharvey Date 2013-07-05 Time 14:27 Rev Time 0.00
Received By dharvey Date 2013-06-20 Time 15:30 Sent To  
Notes
2013-06-20 15:30:54INCOMING SENT TO B-18 BOX. JW

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2013-07-05 Cont ID  
Sent By jwitmer Date 2013-07-05 Time 14:14 Rev Time 0.00
Received By jwitmer Date 2013-07-05 Time 14:14 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2013-06-27 Cont ID  
Sent By lwagner Date 2013-06-27 Time 14:09 Rev Time 0.00
Received By lwagner Date 2013-06-27 Time 13:23 Sent To  
Notes
2013-06-27 14:09:23***PROVISO***
 HI / LOW DRINKING FOUNTAIN IS REQUIRED.
 FBC ACCESSIBILITY 211.2

Review Stop Z ZONING
Rev No 1 Status N Date 2013-06-24 Cont ID  
Sent By ajones Date 2013-06-24 Time 18:50 Rev Time 0.00
Received By ajones Date 2013-06-24 Time 18:50 Sent To  
Notes
***NONE***