Plan Review Details - Permit 13060657
| Plan Review Stops For Permit 13060657 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2013-09-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-09-27 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-09-27 |
Time |
12:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2013-08-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-08-22 |
Time |
20:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-08-22 |
Time |
20:54 |
Sent To |
|
|
| Notes |
| 2013-08-22 20:56:46 | ****PROVISO**** | | | ****SEPARATE PERMIT REQUIRED FOR SHUTTERS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. IMPACT PROTECTION REQUIRED,FBC1609.1.4, FBC R | | | 301.2.1.2. PROVIDE PRODUCT APPROVALS AND, IF SHUTTERS | | | ARE USED, COMPLETE THE SAMPLE INSTALLATION SCHEDULE | | | (AVAILABLE IN THE LOBBY AND AT | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | | INSTALLATION.PDF) | | | | | | INSTALLATION SCHEDULE WAS NOT PROVIDED AT TIME OF | | | RESUBMITTAL. SUBMIT PRODUCT APPROVAL AND INSTALLATION | | | SCHEDULE WITH PERMIT APPLICATION. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2013-07-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-07-26 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-07-26 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2013-07-26 14:51:28 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | COMMENTS FROM PREVIOUS LIST: | | | | | | 1. PROVIDE A FLOOR PLAN SHOWING: WINDOW LOCATIONS, | | | SIZES, WINDOW TYPE, ROOM DESIGNATIONS. NOTE EXISTING | | | CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE FOR | | | BEDROOMS, FBC R310, FBC EB 604.1. THE CLEAR OPENING | | | CANNOT BE REDUCED BY MORE THAN 5%. | | | | | | 2ND REVIEW - | | | | | | MASTER BEDROOM SHOWS A "BLOCKED EXISTING DOOR." WHAT | | | DOES THIS MEAN? IF THIS WAS AN EXISTING DOOR WHICH WAS | | | REMOVED AND BLOCKED, THIS WAS THE EMERGENCY MEANS OF | | | ESCAPE FOR THE BEDROOM. OTHER WINDOW IS SHOWN AS 48" | | | HIGH, WHICH DOES NOT COMPLY. REVISE PLAN TO INSTALL A | | | DOOR IN PREVIOUS LOCATION OR PROVIDE AN INFILL DETAIL | | | AND COMPLIANT MEANS OF EMERGENCY ESCAPE AND RESCUE OR | | | CLARIFY CONDITIONS PRIOR TO CONSTRUCTION PERFORMED | | | WITHOUT PERMIT. | | | | | | PROVIDE THE ADDITIONAL INFORMATION REQUESTED - TYPE OF | | | EXISTING (PRIOR TO CHANGE) OF WINDOW IN THE BEDROOMS, | | | CLEAR OPENING THAT WAS EXISTING, NEW CLEAR OPENING. | | | | | | 2. IMPACT PROTECTION REQUIRED,FBC1609.1.4, FBC R | | | 301.2.1.2. PROVIDE PRODUCT APPROVALS AND, IF SHUTTERS | | | ARE USED, COMPLETE THE SAMPLE INSTALLATION SCHEDULE | | | (AVAILABLE IN THE LOBBY AND AT | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | | INSTALLATION.PDF) | | | | | | IF THIS FALLS UNDER THE 25% EXCEPTION FBC EB 606.4, | | | PROVIDE CALCULATIONS. | | | | | | NOT ADDRESSED. PLAN STATES THAT THERE ARE EXISTING | | | ACCORDION SHUTTERS, BUT NO PERMIT ON FILE FOR THIS | | | WORK. PLEASE ADDRESS. | | | | | | 3. PROVIDE A STRUCTURAL DETAIL FOR THE NEW WALL INFILL, | | | FBC 107, FBC R 301. | | | | | | NOT ADDRESSED. INCLUDE WIND DESIGN CRITERIA AND THE | | | PRINTED NAME AND SIGNATURE OF THE INDIVIDUAL TAKING | | | RESPONSIBILITY FOR THE PLAN. | | | | | | 4. OK | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-06-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-06-27 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-06-27 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2013-06-27 08:52:13 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. PROVIDE A FLOOR PLAN SHOWING: WINDOW LOCATIONS, | | | SIZES, WINDOW TYPE, ROOM DESIGNATIONS. NOTE EXISTING | | | CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE FOR | | | BEDROOMS, FBC R310, FBC EB 604.1. THE CLEAR OPENING | | | CANNOT BE REDUCED BY MORE THAN 5%. | | | | | | 2. IMPACT PROTECTION REQUIRED,FBC1609.1.4, FBC R | | | 301.2.1.2. PROVIDE PRODUCT APPROVALS AND, IF SHUTTERS | | | ARE USED, COMPLETE THE SAMPLE INSTALLATION SCHEDULE | | | (AVAILABLE IN THE LOBBY AND AT | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | | INSTALLATION.PDF) | | | | | | IF THIS FALLS UNDER THE 25% EXCEPTION FBC EB 606.4, | | | PROVIDE CALCULATIONS. | | | | | | 3. PROVIDE A STRUCTURAL DETAIL FOR THE NEW WALL INFILL, | | | FBC 107, FBC R 301. | | | | | | 4. TWO COMPLETE COLLATED SETS OF PLANS AND DOCUMENTS | | | REQUIRED FOR PERMIT ISSUANCE. FAILURE TO PROVIDE TWO | | | SETS MAY RESULT IN ADMINISTRATIVE FEES. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2013-09-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-09-27 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-09-17 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2013-09-17 14:12:05 | RESUBMITTAL SENT TO SAMANTHA'S DESK FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-08-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-08-22 |
Time |
20:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-08-13 |
Time |
10:13 |
Sent To |
|
|
| Notes |
| 2013-08-13 10:14:20 | SENT TO SAMANTHA'S DESK FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-07-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-07-26 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-07-18 |
Time |
15:24 |
Sent To |
|
|
| Notes |
| 2013-07-18 15:24:37 | TO SH DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-06-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-06-27 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-06-18 |
Time |
17:25 |
Sent To |
|
|
| Notes |
| 2013-06-18 17:25:45 | TO BLDG < $5K |
|
|
|