Plan Review Details - Permit 13060521
Plan Review Stops For Permit 13060521
Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2013-06-20 Cont ID  
Sent By Mgonzale Date 2013-06-20 Time   Rev Time 1.00
Received By mgonzale Date 2013-06-20 Time 09:33 Sent To P
Notes
2013-06-20 13:43:053333 TURTLE COVE, WPB, FL 33411
 OWNER OF PROPERTY WISHES TO INSTALL IN-GROUND YARD
 DRAIN SYSTEM TO GET RID OF EXCESS RAINWATER.
 THIS WILL ALLOW RAIN WATER TO DRAIN CLEAR OF THE HOUSE
 AND POOL AREA.
 TYPICAL YARD DRAIN SYSTEM COMPOSED OF 6" DIAMETER
 PERFORATED TUBE RESTING ON 4" OF CRUSHED ROCK
 TO PERCOLATE EXCESS RAINWATER.
 PROJECT PROPOSES LINES AND DRAINS ON-SITE, AND WILL NOT
 ENCROACH INTO ANY EASEMENTS.
  
 WATER MUST BE PERCOLATED ON-SITE. IT IS PROHIBITED TO
 DISCHARGE WATER.
 MUNICIPAL CODE SEC. 90-203. - PROHIBITED DISCHARGES;
 ILLICIT CONNECTIONS.
 GENERAL PROHIBITION. EXCEPT AS PROVIDED IN SECTION
 90-205, AND EXCEPT PURSUANT TO A VALID
 NPDES PERMIT, IT SHALL BE UNLAWFUL FOR ANY PERSON TO
 DIRECTLY OR INDIRECTLY DEPOSIT, DISCHARGE,
 SPILL, OR DUMP INTO ANY OF THE PUBLIC WATERS OR
 MUNICIPAL SEPARATE STORM SEWER SYSTEM WITHIN
 THE CITY, ANY SUBSTANCE OTHER THAN THAT COMPOSED
 ENTIRELY OF STORMWATER.
 SITE OF INDUSTRIAL ACTIVITY. EXCEPT AS PROVIDED IN
 SECTION 90-205, ANY DIRECT OR INDIRECT
 DISCHARGE FROM A SITE OF INDUSTRIAL ACTIVITY TO THE
 SEPARATE STORM SEWER SYSTEM OWNED BY THE
 CITY WHICH DOES NOT COMPLY WITH, OR IS NOT PURSUANT TO,
 A VALID NPDES PERMIT IS PROHIBITED.
 ILLICIT CONNECTIONS. NO PERSON MAY MAINTAIN, USE OR
 ESTABLISH ANY DIRECT OR INDIRECT CONNECTION
 TO THE STORMWATER SYSTEM THAT RESULTS IN ANY DISCHARGE
 IN VIOLATION OF THIS ARTICLE. THIS
 PROHIBITION IS RETROACTIVE AND APPLIES TO CONNECTIONS
 MADE IN THE PAST, REGARDLESS OF WHETHER
 MADE UNDER A PERMIT, OR OTHER AUTHORIZATION, OR WHETHER
 PERMISSIBLE UNDER LAWS OR PRACTICES
 APPLICABLE OR PREVAILING AT THE TIME THE CONNECTION WAS
 MADE.
 (CODE 1979, ? 32-18)
  
 PLEASE CONTACT ME SHOULD YOU HAVE ANY QUESTIONS OR
 CONCERNS.
  
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES AND PUBLIC WORKS DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-06-20 Cont ID  
Sent By lwagner Date 2013-06-20 Time 14:22 Rev Time 0.00
Received By lwagner Date 2013-06-13 Time 10:36 Sent To  
Notes
2013-06-14 10:37:05SENT TO PLUMBING UNDER $5000 BOX

Review Stop P PLUMBING
Rev No 1 Status P Date 2013-06-20 Cont ID  
Sent By lwagner Date 2013-06-20 Time 14:22 Rev Time 0.00
Received By lwagner Date 2013-06-18 Time 09:26 Sent To  
Notes
***NONE***