Plan Review Details - Permit 13060473
| Plan Review Stops For Permit 13060473 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-07-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-07-26 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-07-26 |
Time |
12:58 |
Sent To |
|
|
| Notes |
| 2013-07-26 13:21:40 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. PROVIDE INFORMATION REGARDING THE WINDOWS AND DOORS | | | WHICH OPEN INTO THE PROPOSED SCREEN ENCLOSURE. PROVIDE | | | A PLAN WHICH SHOWS ROOM DESIGNATIONS FOR EACH OPENING. | | | IF BEDROOMS ARE AFFECTED, SHOW ALTERNATE MEANS OF | | | EMERGENCY ESCAPE AND RESCUE FBC 2010 RESIDENTIAL 310. | | | PROVIDE EXISTING CLEAR OPENING, PROPOSED NEW CLEAR | | | OPENING. | | | | | | PLEASE FEEL FREE TO CONTACT ME PRIOR TO RESUBMITTAL IF | | | YOU NEED ASSISTANCE. | | | | | | 2. PROVIDE A SITE PLAN WHICH SHOWS DISTANCE OF PROPOSED | | | IMPROVEMENT TO LOT LINES, FBC 2010 RESIDENTIAL 302. | | | | | | 3. PLAN SHOWS SHINGLES, APPLICATION STATES "PLEXI | | | ROOF." CORRELATE AND PROVIDE PRODUCT APPROVAL FOR ROOF | | | COVERING FAC9N-3. | | | | | | 4. SEE FBC 2010 RESIDENTIAL 301; IT APPEARS THIS IS | | | LOCATED IN EXPOSURE C. EITHER REVISE OR PROVIDE | | | RATIONALE FOR DESIGN TO EXPOSURE B. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2013-06-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-06-14 |
Time |
07:11 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-06-14 |
Time |
07:11 |
Sent To |
|
|
| Notes |
| 2013-06-14 07:12:12 | NO ELECTRICAL WORK IS SHOWN ON THE PLANS. SEPARATE | | | PERMIT, APPLICATION AND REVIEW IS REQUIRED FOR | | | ELECTRICAL WORK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-07-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-07-26 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-06-13 |
Time |
07:11 |
Sent To |
|
|
| Notes |
| 2013-06-14 07:13:46 | SENT TO ZONING BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2013-06-26 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2013-06-26 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2013-06-19 |
Time |
15:13 |
Sent To |
B |
|
| Notes |
| 2013-06-26 15:04:36 | 6/26/13 FAILED A SURVEY OR SITE PLAN MUST BE PROVIDED | | | SHOWING THE LOCATION OF THE SCREEN ENCLOSURE IN | | | RELATIONSHIP TO THE PROPERTY LINE AND HOUSE. | | | | | | ANGELLA VANN | | | 561-822-1441 | | | [email protected] |
|
|
|