Plan Review Details - Permit 13060228
| Plan Review Stops For Permit 13060228 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2014-05-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-05-28 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-05-27 |
Time |
09:29 |
Sent To |
|
|
| Notes |
| 2014-05-27 15:41:27 | BUILDING PLAN REVIEW | | | PERMIT: 13060228 | | | ADD: 8170 OKEECHOBEE BLVD BLDG #5& 6 | | | CONT: ATLANTIC ENGINEERING SERVICES | | | TEL: (561)267-5941 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 3RD REVIEW | | | DATE: TUES. MAY 27 /2014 | | | ACTION: PROVISO | | | | | | 1) THE UNITY OF TITLE HAS NOT BEEN RECORDED AT THE | | | COUNTY CLERK OF THE COURT, THIS PROCEDURE HAS TO | | | COMPLETED BEFORE A CERTIFICATE OF COMPELTION WILL BE | | | ISSUED FOR THE SHELL BUILDINGS 5 & 6. A HOLD WILL BE | | | PUT ON THE PRINTING OF THE CERTIFICATE OF COMPLETION. | | | | | | 2) PLEASE PROVIDE ROOFTOP A/C CURB PRODUCT APPROVAL. | | | 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41 | | | COMPONENTS & CLADDING | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(D) ROOFING PRODUCTS AND ASSEMBLIES (ROOF TOP A/C | | | CURBING) | | | | | | 3) ROOFING PRODUCT APPROVALS SUBMITTED: | | | | | | MIAMI DADE NOA: 13-0129.07 / PAGES 1-18 | | | JOHN MANVILLE BUILT-UP ROOFING SYSTEM OVER STEEL DECKS | | | NO-SUB-SYSTEM IS IDENTIFIED MAY REQUIRE ENHANCED | | | FASTENING IN ROOFING ZONES 2 & 3. NOTE OVER 3 FOOT | | | PARAPET NO ZONE 3 REQUIREMENTS. | | | | | | MIAMI DADE NOA: 13-0129.19 / PAGES 1-38 | | | JOHN MANVILLE BUILT-UP ROOFING SYSTEM OVER STEEL DECKS | | | NO-SUB-SYSTEM IS IDENTIFIED MAY REQUIRE ENHANCED | | | FASTENING IN ROOFING ZONES 2 & 3. NOTE OVER 3 FOOT | | | PARAPET NO ZONE 3 REQUIREMENTS. | | | | | | MIAMI DADE NOA: 13-0529.06 PAGES 1-17 | | | JOHN MANVILLE BUILT-UP ROOFING SYSTEM OVER STEEL DECKS | | | NO-SUB-SYSTEM IS IDENTIFIED MAY REQUIRE ENHANCED | | | FASTENING IN ROOFING ZONES 2 & 3. NOTE OVER 3 FOOT | | | PARAPET NO ZONE 3 REQUIREMENTS. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2013-11-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-11-04 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-11-04 |
Time |
10:30 |
Sent To |
|
|
| Notes |
| 2013-11-04 12:19:47 | BUILDING PLAN REVIEW | | | PERMIT: 13060228 | | | ADD: 8170 OKEECHOBEE BLVD BLDG #5& 6 | | | CONT: ATLANTIC ENGINEERING SERVICES | | | TEL: (561)267-5941 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 1ST REVIEW | | | DATE: JULY 10/2013 | | | ACTION: DENIED | | | | | | 1) 2ND REQUEST!!!!!THE SURVEY INDICATES THIS SITE IS | | | LOCATED IN A AH FLOOD ZONE (EL 17'). THE CITY MUNI-CODE | | | SECTION 94-546 (B)(2) NONRESIDENTIAL CONSTRUCTION DOES | | | ALLOW FOR EITHER THE LOWEST FLOOR ELEVATION TO BE | | | ELEVATED SIX INCHES HIGHER THAN THE BASE FLOOD | | | ELEVATION OR, TOGETHER WITH THE ATTENDANT UTILITES AND | | | SANITARY FACILITIES, BE FLOODPROOFED SO THAT BELOW THE | | | SIX INCHES ABOVE THE BASE FLOOD LEVEL THE STRUCTURE IS | | | WATER TIGHT. | | | THREE FLOOD ZONE CERTIFICATES WILL BE REQUIRED DURING | | | THE CONSTRUCTION PROCESS AND BEFORE A CERTIFICATE OF | | | COMPLETION CAN BE ISSUED. | | | 1A) THE FIRST FLOOD ELEVATION CERTIFICATE WILL BE THE | | | PROPOSED FINISH FLOOR ELEVATION IN HGVD, TO BE PROVIED | | | TO THE CITY BEFORE PERMIT ISSUANCE. | | | 1B) THE SECOND FLOOD ELEVATION CERTIFICATE WILL BE | | | REQUIRED AFTER THE FLOOR SLAB IS POURED. | | | 1C) THE THIRD CERTIFICATE WILL BE REQUIRED PRIOR TO THE | | | CERTIFICATTE OF COMPLETION, WITH THE HEIGHT OF ANY SLAB | | | FOR A/C CONDENSORS. | | | | | | FEMA FORM OMB NO. 1660-0008 EXPIRES: | | | JULY 31,2015 | | | | | | FEMA'S NEW ELEVATION CERTIFICATE (EC) WAS APPROVED FOR | | | USE, EFFECTIVE AUGUST 1/ 2012, THROUGH JULY 31/ 2015. | | | THE NEW EC WILL BE PHASED IN ON A VOLUNTARY BASIS UNTIL | | | SEPTEMBER 30/ 2013. ALTHOUGH THE OLD VERSION OF THE | | | FORM IS NO LONGER AVAILABLE FOR DISTRIBUTION, EXISTING | | | COPIES MAY BE USED UNTIL SEPTEMBER 30/2013. ELEVATIONS | | | CERTIFIED ON OR AFTER OCTOBER 1/2013, MUST BE SUBMITTED | | | ON THE NEW FORM. | | | | | | ADDITIONAL INFORMATION ON THE DIFFERENCES, THE NEW | | | FORM, AND INSTRUCTIONS ARE AVAILABLE AT: | | | HTTP://WWW.FEMA.GOV/BUSINESS/NFIP/ELVINST.SHTM | | | | | | 2)SEMI-COMPLIED. SHEET A1 INDICATES THIS BUILDING WAS | | | DESIGNED AS A TYPE 5B UNSPRINKLERED BUILDING, THE PLANS | | | REFERENCE TABLE 503 , MERCANTILE AND ALLOWED AREA AS | | | 13,200 SQ FT. PLEASE REVIEW THE 2010 FBC-B TABLE 503, | | | MERCANTILE ONLY ALLOWS 9,000 SQ FT FOR A TYPE VB | | | -UNSPRINKLERED BUILDING. PLEASE REVIEW FBC-B 903.2.7 | | | (1) MERCANTILE WITH FIRE AREAS THAT EXCEED 12,000 SQ FT | | | REQUIRE FIRE SPRINKLERS. PLEASE NOTE THE BUILDING | | | FOOTPRINT OR AREA IS TAKEN FROM THE INTERIOR SIDE OF | | | THE EXTERIOR WALL, OR APPROXIMATELY 12,902 SQ FT. THIS | | | STILL EXCEEDS THE 9,000 SQ FT ALLOWED BY TABLE 503.1. | | | IF THE DESIGNER WISHES TO TAKE BUILDING AREA | | | MODIFICATIONS FOR FRONTAGE INCREASE (506.2) PLEASE | | | PROVIDE THE FORMULA ON THE PLANS AND STATE AS SUCH, | | | AREA INCREASE TAKEN. | | | | | | THIS PERMIT IS FOR THE BUILDING OF BUILDINGS 5 & 6 | | | CONNECTED BY A (4) HOUR FIRE WALL. THE ISSUE IS THE | | | PROPERTY APPRAISERS OFFICE INDICATES AS WELL AS THE | | | SURVEY THE TWO BUILDINGS ARE ON 2 SEPARATE PARCELS OF | | | LAND, BLDG # 5 ONTRACT E 74-442-43-29-30-005-0000 AND | | | BLDG # 6 ON TRACT 74-42-43-29-30-004-0000. AUNITY OF | | | TITLE WIL BE REQUIRED TO UNIT THESE 2 TRACTS OF LAND SO | | | THERE WILL BE NO PROPERTY LINE BETWEEN THEM. | | | | | | UNITY OF TITLE. THE PROPOSED BUILDING STRUCTURE | | | TRANSGRESSES LEGAL BOUNDARY LINES BETWEEN THE LOTS | | | WHICH COMBINE TO FORM 'THE SITE'. A 'UNITY OF TITLE' | | | SHALL BE | | | RECORDED AT THE COUNTY COURTHOUSE. SUBMIT A COPY OF THE | | | RECORDED 'UNITY OF OF TITLE' DOCUMENT SO THAT FBC TABLE | | | 601 BOUNDARY LINE REQUIREMENTS MAY BE DEEMED | | | NOT APPLICABLE. | | | SEE WEBSITE FOR APPLICATION: | | | HTTP://WWW.WPB.ORG/ENGINEERING/ENG_FORMS.PHP | | | "APPLICATION FOR UNITY OF TITLE" | | | | | | HTTP://WWW.WPB.ORG/ENGINEERING/UPLOADS/2010-10-12-14-45 | | | -38-UNITYOFTITLE3.PDF | | | | | | VINCENT J NOEL | | | SURVEYOR/REAL ESTATE SUPERVISOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FL 33401 | | | PHONE: 494-1040 EXT: 1096 | | | FAX: 494-1116 | | | E-MAIL: [email protected] | | | | | | ********************************************* | | | | | | MANUEL JULIAN GONZALEZ | | | ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | 3) 2ND REQUEST, IN THE RESPONSE LETTER IT DOES STATE | | | THAT A NEW EASEMENT IS TO BE SECURED. IN THE WEST SIDR | | | OF THE SURVEY AND NOTE # 7 INDICATE A PALM BEACH COUNTY | | | UTILITY EASEMENT THAT IS TO BE VACATED, PLEASE SHOW | | | DOCUMENTATION AS SUCH. 107.2.1 ADDITIONAL INFORMATION. | | | | | | 4A) 2ND REQUEST, SHEET A3 EAST ELEVATION SHOWS A | | | PERCENTAGE OF OPENINGS (WINDOWS & DOORS), THE SURVEY | | | INDICATES THE DISTANCE TO THE PROPERTY LINE IS 9.6 FT. | | | PLEASE EITHER PROVIDE THE PER CENT AGE OF ALLOWABLE | | | OPENINGS 5-10 FT , 10% UNPROTECTED OPENINGS OR WHAT | | | ARRANGEMENT HAS BEEN MADE THAT TRACT A CAN NEVER BE | | | SOLD AND THE AREA CAN BE COUNTED AS PART OF THE FIRE | | | DISTANCE SEPERATION? THE OWNERS MUST PRODUCE EITHER | | | TYPE OF THESE TYPES OF DOCUMENTS, UNITY OF CONTROL, A | | | RESTRICTIVE COVENENT OR A UNITY OF TITLE FOR THE AMOUNT | | | OF QPENINGS AND THE CLOSENESS OF THE PREOPERTY LINE | | | SHOWN ON BOTH THE SURVEY AND THE PBC PROPERTY | | | APPRAISERS WEB SITE. DIRECTLY EAST OF TRACT D IS COMMON | | | TRACT A 8120 OKEECHOBEE BLVD PCN | | | 74-42-43-29-30-001-0000. | | | | | | 4B) 2ND REQUEST, BUILDING #6 TRACT D, SEE SURVEY FOR | | | LOT LINE TO BUILDING DISTANCE (IRC LB # 7344) MARKERS | | | SEE SURVEY. SHEET A3 SOUTH ELEVATION INDICATES WINDOWS | | | IN THIS WALL SECTION THAT ARE 3.7 FT AWAY FROM THE | | | PROPERTY LINE, THE WALL SHOWS COMPLIANCE WITH TABLE | | | 602, PLEASE SHOW CODE COMPLIANCE FOR OPENINING 3-5 FT | | | FROM THE PROPERTY LINE, TABLE 705.8 NOT PERMITED FOR | | | UNPROTECTED WINDOWS. | | | | | | 4C) 2ND REQUEST, SHEET A2 THE EAST SIDE OF BUILDING # 5 | | | LOCATED ON TRACT E, SEE SURVEY INDICATES THE DISTANCE | | | FROM THE PROPERTY LINE AS 6.2 FT AWAY, SHOW COMPLIANCE | | | WITH ALLOWABLE OPENINGS FOR WINDOWS & A DOORS FROM THE | | | PROPERTY LINE. PLEASE PROVIDE COMPLIANCE WITH FBC-B | | | TABLE 705.8 10 % OPENINGS. | | | | | | 5) 2ND REQUEST, SHEET A2 PLEASE PROVIDE CODE COMPLIANCE | | | FOR 2010 FBC-ENERGY 502.2.3.1 SHELL BUILDINGS. THE | | | ENERGY CALCULATIONS INDICATE THE ROOF INSULATION TO BE | | | A R-40 | | | SHEET A2 INDICATES TYPES OF INSULATION TO BE INSTALLED | | | PLEASE PROVIDE HOW THEY WILL ACHIEVE A R-40 VALUE, NOTE | | | WITHIN THE ENERGY CALCULATIONS SUBMITED FOR SHELL | | | BUILDINGS UNDER THE HEADING MATERIALS USED THERE ARE NO | | | MATERIALS LISTED FOR THE ROOFING SHOWING A VALUE OF | | | R40. 2010 FL ENERGY CODE TABLE 502.1.1.1(1). ENVELOPE | | | PRESRIPTIVE MEASURES FOR SHELL BUILDINGS. THE PLANS | | | SHOW MATERIAL TO BE INSTALLED BUT NOT IN THE ENERGY | | | DOCUMENTS THAT PROVIDE THE R-VALUE FOR EACH COMPONENT. | | | | | | 6)COMPLIED. SHEET A5 DETAIL # 1 THE PARAPET IS MISSING | | | COPING. 2010 FBC-B PARAPET WALLS SHALL BE PROPERLY | | | COPED WITH NONCOMBUSTIBLE, WEATHERPROOF MATERIALS OF A | | | WIDTH NO LESS THAN THE THICKNESS OF THE PARAPET WALL. | | | METAL COPING SHALL COMPLY WITH ANSI/SPRI ES-1 OR RAS | | | 111. | | | | | | 7) SEMI-COMPLIED. 2010 FBC 107.3.4.1 PRODUCT APPROVALS. | | | THOSE PRODUCTS WHICH ARE REGULATED BY THE DCA RULE | | | 9N-03 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE | | | ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING | | | ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC.. | | | | | | 8) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.41 COMPONENTS & CLADDING | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)((D) ROOFING PRODUCTS AND ASSEMBLIES | | | SUBMITTED WERE (2) ROOFING PRODUCT APPROVALS FOR FLAT | | | ROOFS | | | NOA 13-0129.07 1OF 18 SHEETS NO SUB-SYSTEM IDENTIFIED | | | SEE EITHER LIMITATION # 7 OR 9 PER SUB-SYSTEM | | | NOA 13-0129.19 1OF 38 SHEETS, NO SUB-SYSTEM IDENTIED | | | SEE EITHER LIMITATION # 7 OR 9 PER SUB-SYSTEM | | | (E) PRE-ENGINEERED A/C STANDS | | | | | | 9) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 10) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-07-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-07-11 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-07-11 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2013-07-11 11:29:16 | BUILDING PLAN REVIEW | | | PERMIT: 13060228 | | | ADD: 8170 OKEECHOBEE BLVD BLDG # 6 | | | CONT: ATLANTIC ENGINEERING SERVICES | | | TEL: (561)267-5941 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 1ST REVIEW | | | DATE: JULY 10/2013 | | | ACTION: DENIED | | | | | | 1) THE SURVEY INDICATES THIS SITE IS LOCATED IN A AH | | | FLOOD ZONE (EL 17'). THE CITY MUNI-CODE SECTION 94-546 | | | (B)(2) NONRESIDENTIAL CONSTRUCTION DOES ALLOW FOR | | | EITHER THE LOWEST FLOOR ELEVATION TO BE ELEVATED SIX | | | INCHES HIGHER THAN THE BASE FLOOD ELEVATION OR, | | | TOGETHER WITH THE ATTENDANT UTILITES AND SANITARY | | | FACILITIES, BE FLOODPROOFED SO THAT BELOW THE SIX | | | INCHES ABOVE THE BASE FLOOD LEVEL THE STRUCTURE IS | | | WATER TIGHT. | | | THREE FLOOD ZONE CERTIFICATES WILL BE REQUIRED DURING | | | THE CONSTRUCTION PROCESS AND BEFORE A CERTIFICATE OF | | | COMPLETION CAN BE ISSUED. | | | 1A) THE FIRST FLOOD ELEVATION CERTIFICATE WILL BE THE | | | PROPOSED FINISH FLOOR ELEVATION IN HGVD. | | | 1B) THE SECOND FLOOD ELEVATION CERTIFICATE WILL BE | | | REQUIRED AFTER THE FLOOR SLAB IS POURED. | | | 1C) THE THIRD CERTIFICATE WILL BE REQUIRED PRIOR TO THE | | | CERTIFICATTE OF COMPLETION, WITH THE HEIGHT OF ANY SLAB | | | FOR A/C CONDENSORS. | | | | | | FEMA FORM OMB NO. 1660-0008 EXPIRES: | | | JULY 31,2015 | | | | | | FEMA'S NEW ELEVATION CERTIFICATE (EC) WAS APPROVED FOR | | | USE, EFFECTIVE AUGUST 1/ 2012, THROUGH JULY 31/ 2015. | | | THE NEW EC WILL BE PHASED IN ON A VOLUNTARY BASIS UNTIL | | | SEPTEMBER 30/ 2013. ALTHOUGH THE OLD VERSION OF THE | | | FORM IS NO LONGER AVAILABLE FOR DISTRIBUTION, EXISTING | | | COPIES MAY BE USED UNTIL SEPTEMBER 30/2013. ELEVATIONS | | | CERTIFIED ON OR AFTER OCTOBER 1/2013, MUST BE SUBMITTED | | | ON THE NEW FORM. | | | | | | ADDITIONAL INFORMATION ON THE DIFFERENCES, THE NEW | | | FORM, AND INSTRUCTIONS ARE AVAILABLE AT: | | | HTTP://WWW.FEMA.GOV/BUSINESS/NFIP/ELVINST.SHTM | | | | | | 2) SHEET A1 INDICATES THIS BUILDING WAS DESIGNED AS A | | | TYPE 5B UNSPRINKLERED BUILDING, THE PLANS REFERENCE | | | TABLE 503 , MERCANTILE AND ALLOWED AREA AS 13,200 SQ | | | FT. PLEASE REVIEW THE 2010 FBC-B TABLE 503, MERCANTILE | | | ONLY ALLOWS 9,000 SQ FT FOR A TYPE VB -UNSPRINKLERED | | | BUILDING. PLEASE REVIEW FBC-B 903.2.7 (1) MERCANTILE | | | WITH FIRE AREAS THAT EXCEED 12,000 SQ FT REQUIRE FIRE | | | SPRINKLERS. PLEASE NOTE THE BUILDING FOOTPRINT OR AREA | | | IS TAKEN FROM THE INTERIOR SIDE OF THE EXTERIOR WALL, | | | OR APPROXIMATELY 12,902 SQ FT. THIS STILL EXCEEDS THE | | | 9,000 SQ FT ALLOWED BY TABLE 503.1. IF THE DESIGNER | | | WISHES TO TAKE BUILDING AREA MODIFICATIONS FOR FRONTAGE | | | INCREASE (506.2) PLEASE PROVIDE THE FORMULA ON THE | | | PLANS AND STATE AS SUCH, AREA INCREASE TAKEN. | | | | | | THERE IS A DISCREPANCY BETWEEN THE SP-1 AND SHEET A-1. | | | THE SITE PLAN INDICATES ON THE NORTHWEST CORNER OF THE | | | BUILDING 1 DOORWAY AND LANDING, THIS DOOR WAY IS NOT | | | LOCATED ON THE A1 SHEET. FURTHER MORE AS FOR THE SHELL | | | BUILDING WITH THE TENANT LINES AS SHOWN IS CODE | | | COMPLIANT FOR COMMON PATH OF TRAVEL UNDER 75 FEET AND A | | | OCCUPANT LOAD OF LESS THAN 50. IF ON ANY TENANT | | | BUILD-OUT ANY WHERE TWO TENANT SPACES ARE COMBINED THE | | | OCCUPANT LOAD IS OVER 50, THE CODE (TABLE 1015.1) WOULD | | | TWO EXIT DOORS, AND THE TWO FRONT ENTRY DOORS DO NOT | | | COMPLY WITH FBC-B 1015.2.1 DOORS BEING 1/2 THE DIAGONAL | | | DISTANCE APART REQUIRING EITHER A DOOR TO THE REAR OF | | | THE UNIT OR THE FRONT ENTRY DOORS BEING RELOCATED TO | | | MEET THE 1/2 THE DIADONAL DISTANCE APART. | | | | | | 3) IN THE WEST SIDR OF THE SURVEY AND NOTE # 7 INDICATE | | | A PALM BEACH COUNTY UTILITY EASEMENT THAT IS TO BE | | | VACATED, PLEASE SHOW DOCUMENTATION AS SUCH. 107.2.1 | | | ADDITIONAL INFORMATION. | | | | | | 4A) SHEET A3 EAST ELEVATION SHOWS A PERCENTAGE OF | | | OPENINGS (WINDOWS & DOORS), THE SURVEY INDICATES THE | | | DISTANCE TO THE PROPERTY LINE IS 9.6 FT. PLEASE EITHER | | | PROVIDE THE PER CENT AGE OF ALLOWABLE OPENINGS 5-10 FT | | | , 10% UNPROTECTED OPENINGS OR WHAT ARRANGEMENT HAS BEEN | | | MADE THAT TRACT A CAN NEVER BE SOLD AND THE AREA CAN BE | | | COUNTED AS PART OF THE FIRE DISTANCE SEPERATION? | | | | | | 4B) SHEET A3 SOUTH ELEVATION INDICATES WINDOWS IN THIS | | | WALL SECTION THAT ARE 3.7 FT AWAY FROM THE PROPERTY | | | LINETHE WALL SHOWS COMPLIANCE WITH TABLE 602, PLEASE | | | SHOW CODE COMPLIANCE FOR OPENINING 3-5 FT FROM THE | | | PROPERTY LINE, TABLE 705.8 NOT PERMITED FOR UNPROTECTED | | | WINDOWS. | | | | | | 4C) SHEET A2 THE SOUTH END OF THE BUILDING ALSO SHOWS | | | WINDOWS & A DOOR 6.2 FT AWAY FROM THE PROPERTY LINE. | | | PLEASE PROVIDE COMPLIANCE WITH FBC-B TABLE 705.8 10 % | | | OPENINGS. | | | | | | 5) SHEET A2 PLEASE PROVIDE CODE COMPLIANCE FOR 2010 | | | FBC-ENERGY 502.2.3.1 SHELL BUILDINGS. THE ENERGY | | | CALCULATIONS INDICATE THE ROOF INSULATION TO BE A R-40 | | | WHERE AS SHEET A2 INDICATES TYPES OF INSULATION TO BE | | | INSTALLED PLEASE PROVIDE HOW THEY WILL ACHIEVE A R-40 | | | VALUE. | | | | | | 6) SHEET A5 DETAIL # 1 THE PARAPET IS MISSING COPING. | | | 2010 FBC-B PARAPET WALLS SHALL BE PROPERLY COPED WITH | | | NONCOMBUSTIBLE, WEATHERPROOF MATERIALS OF A WIDTH NO | | | LESS THAN THE THICKNESS OF THE PARAPET WALL. METAL | | | COPING SHALL COMPLY WITH ANSI/SPRI ES-1 OR RAS 111. | | | | | | 7) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 8) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.41 COMPONENTS & CLADDING | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES | | | (E) PRE-ENGINEERED A/C STANDS | | | | | | 9) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2014-06-11 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-06-11 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-06-11 |
Time |
14:38 |
Sent To |
I |
|
| Notes |
| 2014-06-11 15:12:01 | IMPORTANT NOTICE | | | THIS STRUCTURE IS PERMTTED AS AN EMPTY SHELL ONLY. | | | NO OCCUPANCY PERMITTED. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2013-11-25 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2013-11-25 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2013-11-25 |
Time |
08:59 |
Sent To |
|
|
| Notes |
| 2013-11-25 09:50:36 | RETURNED TO BIN | | 2013-11-25 09:48:26 | THE FOLLOW CORRECTIONS AND/OR CLARIFICATIONS SHALL BE | | | SUBMITTED FOR AN ELECTRICAL PLANS APPROVAL | | | 1. THE TITLE BLOCK INDICATES THAT THE PERMIT IS FOR | | | BLDG. 5 & 6, YET THE CLOUD ON THE HOUSE PANEL IS MADE | | | AROUND THE LOAD FOR UNITS 8, 8A & 9. PLEASE CLARIFY | | | THIS. | | | 2. IF THIS IS BLDGS,5 & 6 OF A LARGER PARCEL, THIS HAS | | | TO BE INDICATED AND A SITE PLAN SUBMITTED. | | | 3. THE LOAD CALCS REFLECTED ON THE E1 PAGE ONLY INCLUDE | | | THE "HP" LOAD. A PANEL SCHEDULE REFLECTING THE | | | INDIVIDUAL LOADS OF EACH OF THE UNITS SHALL BE INCLUDED | | | EVEN IF TYPICAL OF ALL, SO SUCH BE ADDRESSED, THESE | | | UNITS SHALL BE EQUIPPED WITH MINIMAL ELECTRIC FOR LIFE | | | SAFETY. | | | 4. YOU SHALL INCLUDE THE MINIMAL EMERGENCY LIGHTING AND | | | ILLUMINATION FOR LIFE SAFETY. | | | 5. PAGE M1, REFLECTS A ROOF MOUNTED A/C TYPICAL OF EACH | | | UNIT WHICH IS NOT INCLUDED IN ANY ELECTRICAL PANEL | | | 6. A COMPLETE SERVICE DIAGRAM SHALL BE PROVIDED | | | INDICATING THE APPROPRIATE LOAD CALCULATIONS. | | | 7. AS PER THE FBC-ENERGY CONSERVATION SECTION 101.4.9 | | | SHELL BUILDINGS A SUBMITTAL COMPLYING SHALL BE | | | SUBMITTED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2013-07-02 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-07-02 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-07-02 |
Time |
12:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2013-07-02 |
|
|
Cont ID |
|
| Sent By |
lphilmor |
Date |
2013-06-21 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-07-02 |
Time |
12:21 |
Sent To |
|
|
| Notes |
| 2013-07-02 12:22:52 | SEE SECOND REVIEW FOR ELECTRIC. RL | | | | | | | | 2013-06-21 12:02:02 | 8146-8160 OKEECHOBEE BLVD. | | | PERMIT #13060228 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | 1. NO ADDRESS PROVIDED IN THE PLAN TITLEBLOCK | | | INFORMATION. | | | 2. PROVIDE A LIFE SAFETY PLAN SHOWING ALL EXIT SIGNS, | | | EMERGENCY LIGHTING, PORTABLE FIRE EXTINGUISHERS. | | | 3. PLAN INDICATES SUITES 1-8, BUT NO FIRE RATED WALLS | | | PROVIDED. | | | 4. THUMB-TURN LOCK TO BE EQUIPPED WITH A LOCK/UNLOCK | | | INDICATOR. | | | 5. CONSTRUCTION TYPE IS REFERENCED TO BE TYPE VB, | | | HOWEVER, PLANS DO NOT APPEAR TO BE WOOD FRAMED | | | STRUCTURE. | | | 6. PLANS INDICATE NO TENANT SEPARATION WALLS AND THE | | | AREA IS INDICIATED AT 13,200 SQ. FT OF MERCANTILE | | | OCCUPANCY. PER NFPA 101 SECTION 36.3.5.1(2) STIPULATES | | | THAT SPRINKLERS ARE REQUIRED FOR MERCANTILE AREAS | | | EXCEEDING 12,000 SQ FT IN GROSS AREA. | | | 7. PROVIDE TACTILE SIGNAGE AT ALL EXIT DOORS. | | | 8. PLANS INDICATE TWO HYDRANTS ON THE SITE. PLEASE | | | INDICATE ANY ADDITIONAL HYDRANTS THAT MAY BE LOCATED TO | | | THE EAST AND SOUTH OF THIS BUILDING. | | | | | | | | | LAUREN PHILMORE | | | FIRE INSPECTOR II / INVESTIGATOR I | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 804-4783 | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2013-08-12 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2013-08-12 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2013-08-12 |
Time |
|
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2014-05-19 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-05-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-05-19 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2014-05-19 11:05:47 | THIS PLAN WAS REVIEWED AND PASSED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENT. | | | | | | NOTICE IS REQUIRED FOR STRUCTURES WITH LIGHT-FRAME | | | TRUSS-TYPE CONSTRUCTION. ANY COMMERCIAL, INDUSTRIAL, OR | | | ANY MULTIUNIT RESIDENTIAL STRUCTURE OF THREE UNITS OR | | | MORE WHICH USES HORIZONTAL OR VERTICAL LIGHT-FRAME | | | TRUSS-TYPE CONSTRUCTION IN ANY PORTION SHALL BE MARKED | | | WITH AN APPROVED SYMBOL. THE APPROVED SYMBOL SHALL BE | | | PLACED WITHIN 24 INCHES TO THE LEFT OF THE MAIN ENTRY | | | DOOR. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2013-12-04 |
|
|
Cont ID |
|
| Sent By |
lphilmor |
Date |
2013-12-04 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
lphilmor |
Date |
2013-12-04 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2013-12-04 15:07:31 | PERMIT # 13060228 | | | PLAN REVIEW COMMENTS - FIRE DEPT | | | | | | PLANS WILL BE STAMPED UPON SATISFACTION OF BUILDING | | | REQUIREMENTS. | | | | | | | | | | | | LAUREN PHILMORE | | | FIRE INSPECTOR II / INVESTIGATOR I | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 804-4783 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2013-06-25 |
|
|
Cont ID |
|
| Sent By |
lphilmor |
Date |
2013-06-25 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
lphilmor |
Date |
2013-06-25 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2013-06-25 14:20:22 | 8146-8160 OKEECHOBEE BLVD. | | | PERMIT #13060228 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | 1. NO ADDRESS PROVIDED IN THE PLAN TITLEBLOCK | | | INFORMATION. | | | 2. PROVIDE A LIFE SAFETY PLAN SHOWING ALL EXIT SIGNS, | | | EMERGENCY LIGHTING, PORTABLE FIRE EXTINGUISHERS. | | | 3. PLAN INDICATES SUITES 1-8, BUT NO FIRE RATED WALLS | | | PROVIDED. | | | 4. THUMB-TURN LOCK TO BE EQUIPPED WITH A LOCK/UNLOCK | | | INDICATOR. | | | 5. CONSTRUCTION TYPE IS REFERENCED TO BE TYPE VB, | | | HOWEVER, PLANS DO NOT APPEAR TO BE WOOD FRAMED | | | STRUCTURE. | | | 6. PLANS INDICATE NO TENANT SEPARATION WALLS AND THE | | | AREA IS INDICIATED AT 13,200 SQ. FT OF MERCANTILE | | | OCCUPANCY. PER NFPA 101 SECTION 36.3.5.1(2) STIPULATES | | | THAT SPRINKLERS ARE REQUIRED FOR MERCANTILE AREAS | | | EXCEEDING 12,000 SQ FT IN GROSS AREA. | | | 7. PROVIDE TACTILE SIGNAGE AT ALL EXIT DOORS. | | | 8. PLANS INDICATE TWO HYDRANTS ON THE SITE. PLEASE | | | INDICATE ANY ADDITIONAL HYDRANTS THAT MAY BE LOCATED TO | | | THE EAST AND SOUTH OF THIS BUILDING. | | | | | | | | | LAUREN PHILMORE | | | FIRE INSPECTOR II / INVESTIGATOR I | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 804-4783 | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2014-11-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-11-04 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-10-09 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2014-10-21 14:44:52 | TO ZONING | | | | | 2014-10-09 15:17:13 | TO SH DESK FOR REVIEW OF ELEVATION CERTIFICATE | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2014-09-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-09-19 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-09-18 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2014-09-18 14:17:43 | SENT TO J WITMER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-06-11 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-06-11 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-05-09 |
Time |
15:57 |
Sent To |
PC |
|
| Notes |
| 2014-06-11 15:12:47 | APPROVED AS NOTED AND PROCESSED. | | 2014-05-14 16:09:50 | C30 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-01-06 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2014-01-06 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2013-10-17 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2013-10-21 09:22:00 | C29 | | | NEW ELEC, PLUMBING, MECH SHEETS SUBMITTED | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-08-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-08-09 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-06-06 |
Time |
13:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
N |
Date |
2014-09-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-09-19 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-09-19 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2014-09-19 09:38:27 | 8146 OKEECHOBEE BLVD | | | PERMIT 13060228 | | | IMPACT FEE ASSESSMENT | | | RECEIPT NO. 2014-0918-271 | | | TRAKING NO. MU-2014-020571-0000 | | | FEES: $39,905.37 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2014-05-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-05-27 |
Time |
17:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-05-27 |
Time |
17:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2013-11-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-11-04 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-11-04 |
Time |
13:04 |
Sent To |
|
|
| Notes |
| 2013-11-04 13:04:20 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2013-07-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-07-11 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-07-11 |
Time |
12:14 |
Sent To |
|
|
| Notes |
| 2013-07-11 12:14:40 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2014-05-28 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-05-28 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-05-28 |
Time |
13:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2013-11-12 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-11-12 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-11-12 |
Time |
13:05 |
Sent To |
|
|
| Notes |
| 2013-11-12 13:06:32 | CURBS ONLY TO BE INSTALLED ON SHELL. | | | AIRCONDITIONING PLAN AND ENERGY CALCULATION | | | REQUIRED FOR EACH BUILDOUT. | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2013-07-12 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-07-12 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-07-12 |
Time |
09:39 |
Sent To |
|
|
| Notes |
| 2013-07-12 09:59:56 | CURBS ONLY TO BE INSTALLED ON SHELL. | | | AIR CONDITIONING PLANS AND ENERGY CALCULATIONS | | | REQUIRED FOR EACH BUILD OUT. | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
P |
Date |
2014-11-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-11-04 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-11-04 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2014-11-04 14:19:52 | PROPOSED FLOOD ELEVATION CERTIFICATE. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2014-05-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-05-27 |
Time |
17:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-05-27 |
Time |
09:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2013-10-30 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-10-30 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-10-30 |
Time |
09:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2013-06-19 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-06-19 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-06-19 |
Time |
14:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2014-10-30 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2014-10-30 |
Time |
08:48 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2014-10-30 |
Time |
08:48 |
Sent To |
B |
|
| Notes |
| 2014-10-30 10:27:45 | PASSED | | | | | | SEPARATE PERMITS, WITH PLANS, ARE REQUIRED FOR THE | | | FOLLOWING: | | | | | | A. LANDSCAPE REQUIRES A SEPARATE PERMIT APPLICATION FOR | | | EACH PARCEL (TRACT A & TRACT F) ON WHICH WORK IS BEING | | | DONE. THE SAME 2 COPIES OF THE LANDSCAPE PLAN MAY BE | | | USED FOR BOTH APPLICATIONS (SUBJECT TO CONCURRENT | | | SUBMITTAL). A COST ESTIMATE IS REQUIRED WITH THE | | | SUBMITTAL. | | | B. SIGNAGE | | | C. AWNINGS | | | D. BICYCLE RACKS | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2014-06-04 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2014-06-04 |
Time |
18:11 |
Rev Time |
0.75 |
| Received By |
eschneid |
Date |
2014-06-04 |
Time |
18:11 |
Sent To |
|
|
| Notes |
| 2014-06-04 18:12:20 | FAILED | | | | | | PLEASE PROVIDE WRITTEN RESPONSES. | | | | | | 1) REPEAT COMMENT: PURSUANT TO RESOLUTION NO. 288-11, A | | | CONSTRUCTION SITE SECURITY AND MANAGEMENT PLAN SHALL BE | | | SUBMITTED TO THE CITY'S POLICE DEPARTMENT CRIME | | | PREVENTION THROUGH ENVIRONMENTAL DESIGN ("CPTED") | | | OFFICIAL AND APPROVED PRIOR TO THE ISSUANCE OF THE | | | BUILDING PERMIT. (CONTRARY TO THE RESPONSE COMMENT, NO | | | PLAN HAS BEEN SUBMITTED TO OFFICER KELLY CARSILLO) | | | | | | I) THE APPLICANT, AFTER SITE CLEARING AND PLACEMENT OF | | | CONSTRUCTION TRAILERS, SHALL INSTITUTE SECURITY | | | MEASURES TO REDUCE OR ELIMINATE OPPORTUNITIES FOR | | | THEFT. THE MANAGEMENT PLAN SHALL INCLUDE, BUT NOT TO BE | | | LIMITED TO, TEMPORARY LIGHTING, SECURITY PERSONNEL, | | | VEHICLE BARRIERS, CONSTRUCTION/VISITOR PASS, | | | REDUCE/MINIMIZE ENTRY/EXIT POINTS, ENCOURAGE | | | SUBCONTRACTORS TO SECURE MACHINERY AND TOOLS AT END OF | | | WORK DAY AND/OR ANY OTHER MEASURE DEEMED APPROPRIATE TO | | | PROVIDE A SAFE AND SECURE WORKING ENVIRONMENT. | | | II) THE SECURITY MANAGEMENT PLAN SHALL BE MAINTAINED | | | THROUGHOUT THE CONSTRUCTION PHASE OF THE PROJECT. | | | NON-COMPLIANCE WITH THE APPROVED PLAN SHALL RESULT IN A | | | STOP-WORK ORDER FOR THE ENTIRE PLANNED DEVELOPMENT. | | | | | | 2) REPEAT COMMENT: IN ACCORDANCE WITH RESOLUTION NO. | | | 288-11, ALL ROOF MOUNTED AIR CONDITIONING, MECHANICAL | | | EQUIPMENT, SATELLITE DISHES, GENERATORS, ETC., SHALL BE | | | SCREENED FROM VIEW ON ALL SIDES BY A VISUALLY OPAQUE | | | BARRIER CONSISTENT WITH THE COLOR, CHARACTER AND | | | ARCHITECTURAL STYLE OF THE STRUCTURES OR EQUIVALENT | | | LANDSCAPE MATERIAL. THE HEIGHT OF THE OPAQUE BARRIER | | | SHALL BE AS REQUIRED TO PROVIDE AMPLE SCREENING. | | | PROVIDE VERIFICATION THAT THE ROOFTOP MECHANICAL | | | EQUIPMENT WILL BE SCREENED AS REQUIRED BY THE | | | RESOLUTION FOR THE SPECIFIC EQUIPMENT PROPOSED FOR | | | INSTALLATION (EX. LINE OF SIGHT OR ELEVATIONS WITH THE | | | EQUIPMENT). | | | | | | 3) NEW COMMENT: THE ELEVATION SUBMITTED WITH THE MINOR | | | AMENDMENT DOES NOT MATCH THE ELEVATION SUBMITTED WITH | | | THE BUILDING PERMIT - THE WINDOW ON THE SOUTH ELEVATION | | | HAS BEEN REMOVED ON THE BUILDING PERMIT SUBMITTAL. THIS | | | IS INTERNAL TO THE SITE, SO STAFF DOES NOT OBJECT TO | | | THE REMOVAL OF THE WINDOW; HOWEVER, ALL PLANS SHALL | | | MATCH. | | | | | | 4) NEW COMMENT: THE CONSTRUCTION LAYOUT SURVEY | | | INCORRECTLY DISPLAYS THE LENGTH OF THE SOUTH SECTION OF | | | THE BUILDING (90 FEET INSTEAD OF 94 FEET). THE SOUTH | | | SETBACK (23.4 FEET) DOES NOT COMPLY WITH THE SETBACK | | | APPROVED ON THE SITE PLAN (19FEET). | | | | | | 5) REPEAT COMMENT: PROVIDE A COPY OF THE REVISED SITE | | | PLAN APPROVED BY ZONING THROUGH THE MINOR AMENDMENT | | | PROCESS. | | | | | | SEPARATE PERMITS, WITH PLANS, ARE REQUIRED FOR THE | | | FOLLOWING: | | | | | | A. LANDSCAPE REQUIRES A SEPARATE PERMIT APPLICATION FOR | | | EACH PARCEL (TRACT A & TRACT F) ON WHICH WORK IS BEING | | | DONE. THE SAME 2 COPIES OF THE LANDSCAPE PLAN MAY BE | | | USED FOR BOTH APPLICATIONS (SUBJECT TO CONCURRENT | | | SUBMITTAL). A COST ESTIMATE IS REQUIRED WITH THE | | | SUBMITTAL. | | | B. SIGNAGE | | | C. AWNINGS | | | D. PARKING LOT STRIPING | | | E. BICYCLE RACKS | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | 2014-05-15 16:21:21 | 5/15/14 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2014-01-06 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2014-01-06 |
Time |
14:40 |
Rev Time |
1.00 |
| Received By |
eschneid |
Date |
2014-01-06 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2014-01-06 14:41:10 | FAILED | | | | | | PLEASE PROVIDE WRITTEN RESPONSES. | | | | | | 1) REPEAT COMMENT: PURSUANT TO THE PALM BEACH COUNTY | | | TRAFFIC PERFORMANCE STANDARDS REVIEW LETTER ISSUED ON | | | SEPTEMBER 17, 2009, NO BUILDING PERMITS SHALL BE ISSUED | | | BY THE CITY AFTER DECEMBER 31, 2012. AN EXTENSION OF | | | THIS DEADLINE MAY BE ISSUED BY PALM BEACH COUNTY. A | | | MINOR PLANNED DEVELOPMENT AMENDMENT IS REQUIRED TO | | | UPDATE THE COUNTY BUILD OUT DATE. | | | | | | 2) REPEAT COMMENT: PURSUANT TO RESOLUTION NO. 288-11, A | | | CONSTRUCTION SITE SECURITY AND MANAGEMENT PLAN SHALL BE | | | SUBMITTED TO THE CITY'S POLICE DEPARTMENT CRIME | | | PREVENTION THROUGH ENVIRONMENTAL DESIGN ("CPTED") | | | OFFICIAL AND APPROVED PRIOR TO THE ISSUANCE OF THE | | | BUILDING PERMIT. (CONTRARY TO THE RESPONSE COMMENT, NO | | | PLAN HAS BEEN SUBMITTED TO OFFICER KELLY CARSILLO) | | | | | | I) THE APPLICANT, AFTER SITE CLEARING AND PLACEMENT OF | | | CONSTRUCTION TRAILERS, SHALL INSTITUTE SECURITY | | | MEASURES TO REDUCE OR ELIMINATE OPPORTUNITIES FOR | | | THEFT. THE MANAGEMENT PLAN SHALL INCLUDE, BUT NOT TO BE | | | LIMITED TO, TEMPORARY LIGHTING, SECURITY PERSONNEL, | | | VEHICLE BARRIERS, CONSTRUCTION/VISITOR PASS, | | | REDUCE/MINIMIZE ENTRY/EXIT POINTS, ENCOURAGE | | | SUBCONTRACTORS TO SECURE MACHINERY AND TOOLS AT END OF | | | WORK DAY AND/OR ANY OTHER MEASURE DEEMED APPROPRIATE TO | | | PROVIDE A SAFE AND SECURE WORKING ENVIRONMENT. | | | II) THE SECURITY MANAGEMENT PLAN SHALL BE MAINTAINED | | | THROUGHOUT THE CONSTRUCTION PHASE OF THE PROJECT. | | | NON-COMPLIANCE WITH THE APPROVED PLAN SHALL RESULT IN A | | | STOP-WORK ORDER FOR THE ENTIRE PLANNED DEVELOPMENT. | | | | | | 3) PRIOR TO THIS ISSUANCE OF THE BUILDING PERMIT: | | | | | | I) REPEAT COMMENT: A SUFFICIENT UNITY OF TITLE TO | | | COMBINE D & E SHALL BE SUBMITTED TO VINCE NOEL, CITY | | | SURVEYOR AND THE UNITY OF TITLE SHALL BE RECORDED. | | | II) REPEAT COMMENT: PROVIDE VERIFICATION THAT THE | | | PORTION OF THE FPL EASEMENT, RECORDED IN ORB 1852, PG | | | 1500, WHICH IS LOCATED UNDER THE PROPOSED BUILDING | | | SHALL HAS BEEN VACATED OR WILL BE ALLOWED TO BE VACATED | | | BY FPL. ADDITIONALLY, ANY UTILITIES THAT WERE IN THE | | | EASEMENT SHALL BE RELOCATED. THE CITY WOULD ISSUE THE | | | PERMIT WITH A PROVISO THAT THE EASEMENT SHALL BE | | | VACATED AND THE UTILITIES RELOCATED PRIOR TO THE FIRST | | | INSPECTION. | | | | | | 4) THE SQUARE FOOTAGE FOR BUILDING #5/6 HAS INCREASED | | | 140 SQUARE FEET FROM THE SEDONA COMMONS MASTER SITE | | | PLAN APPROVED 13,200 SQUARE FEET. THE ADDITIONAL SQUARE | | | FOOTAGE REQUIRES ONE MORE PARKING SPACE ON THE SITE AND | | | A REVISED PALM BEACH COUNTY TRAFFIC LETTER APPROVING | | | THE ADDITIONAL SQUARE FOOTAGE, ALL OF WHICH SHALL BE | | | REFLECTED WITH THE MINOR AMENDMENT APPLICATION AND BE | | | IN PLACE PRIOR TO THE APPROVAL OF THIS PERMIT BY | | | ZONING. | | | | | | 5) REPEAT COMMENT: IN ACCORDANCE WITH RESOLUTION NO. | | | 288-11, ALL ROOF MOUNTED AIR CONDITIONING, MECHANICAL | | | EQUIPMENT, SATELLITE DISHES, GENERATORS, ETC., SHALL BE | | | SCREENED FROM VIEW ON ALL SIDES BY A VISUALLY OPAQUE | | | BARRIER CONSISTENT WITH THE COLOR, CHARACTER AND | | | ARCHITECTURAL STYLE OF THE STRUCTURES OR EQUIVALENT | | | LANDSCAPE MATERIAL. THE HEIGHT OF THE OPAQUE BARRIER | | | SHALL BE AS REQUIRED TO PROVIDE AMPLE SCREENING. | | | PROVIDE VERIFICATION THAT THE ROOFTOP MECHANICAL | | | EQUIPMENT WILL BE SCREENED AS REQUIRED BY THE | | | RESOLUTION FOR THE SPECIFIC EQUIPMENT PROPOSED FOR | | | INSTALLATION (EX. LINE OF SIGHT OR ELEVATIONS WITH THE | | | EQUIPMENT). | | | | | | 6) PROVIDE A COPY OF THE REVISED SITE PLAN ONCE IT IS | | | APPROVED BY ZONING THROUGH THE MINOR AMENDMENT PROCESS. | | | | | | 7) THE LANDSCAPE REQUIRES A SEPARATE PERMIT APPLICATION | | | FOR EACH PARCEL (TRACT A & TRACTS D/E) ON WHICH WORK IS | | | BEING DONE. THE SAME 2 COPIES OF THE LANDSCAPE PLAN MAY | | | BE USED FOR BOTH APPLICATIONS (SUBJECT TO CONCURRENT | | | SUBMITTAL). A COST ESTIMATE IS REQUIRED WITH THE | | | SUBMITTAL. | | | | | | 8) SIGNAGE AND AWNINGS REQUIRE SEPARATE PERMITS WITH | | | PLANS. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | | | 2013-10-30 15:08:41 | 10/29/13 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2013-06-24 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2013-06-24 |
Time |
14:41 |
Rev Time |
3.00 |
| Received By |
eschneid |
Date |
2013-06-24 |
Time |
11:01 |
Sent To |
|
|
| Notes |
| 2013-06-24 15:26:35 | FAILED | | | | | | PLEASE PROVIDE WRITTEN RESPONSES. | | | | | | 1) PURSUANT TO THE PALM BEACH COUNTY TRAFFIC | | | PERFORMANCE STANDARDS REVIEW LETTER ISSUED ON SEPTEMBER | | | 17, 2009, NO BUILDING PERMITS SHALL BE ISSUED BY THE | | | CITY AFTER DECEMBER 31, 2012. AN EXTENSION OF THIS | | | DEADLINE MAY BE ISSUED BY PALM BEACH COUNTY. A MINOR | | | PLANNED DEVELOPMENT AMENDMENT IS REQUIRED TO UPDATE THE | | | THE COUNTY BUILD OUT DATE. | | | | | | 2) PURSUANT TO RESOLUTION NO. 288-11, A CONSTRUCTION | | | SITE SECURITY AND MANAGEMENT PLAN SHALL BE SUBMITTED TO | | | THE CITY'S POLICE DEPARTMENT CRIME PREVENTION THROUGH | | | ENVIRONMENTAL DESIGN ("CPTED") OFFICIAL AND APPROVED | | | PRIOR TO THE ISSUANCE OF THE BUILDING PERMIT. | | | | | | I) THE APPLICANT, AFTER SITE CLEARING AND PLACEMENT OF | | | CONSTRUCTION TRAILERS, SHALL INSTITUTE SECURITY | | | MEASURES TO REDUCE OR ELIMINATE OPPORTUNITIES FOR | | | THEFT. THE MANAGEMENT PLAN SHALL INCLUDE, BUT NOT TO BE | | | LIMITED TO, TEMPORARY LIGHTING, SECURITY PERSONNEL, | | | VEHICLE BARRIERS, CONSTRUCTION/VISITOR PASS, | | | REDUCE/MINIMIZE ENTRY/EXIT POINTS, ENCOURAGE | | | SUBCONTRACTORS TO SECURE MACHINERY AND TOOLS AT END OF | | | WORK DAY AND/OR ANY OTHER MEASURE DEEMED APPROPRIATE TO | | | PROVIDE A SAFE AND SECURE WORKING ENVIRONMENT. | | | II) THE SECURITY MANAGEMENT PLAN SHALL BE MAINTAINED | | | THROUGHOUT THE CONSTRUCTION PHASE OF THE PROJECT. | | | NON-COMPLIANCE WITH THE APPROVED PLAN SHALL RESULT IN A | | | STOP-WORK ORDER FOR THE ENTIRE PLANNED DEVELOPMENT. | | | | | | 3) PRIOR TO THIS ISSUANCE OF THE BUILDING PERMIT: | | | | | | I) A SUFFICIENT UNITY OF TITLE TO COMBINE D & E SHALL | | | BE SUBMITTED TO VINCE NOEL, CITY SURVEYOR AND THE UNITY | | | OF TITLE SHALL BE RECORDED. | | | II) PROVIDE VERIFICATION THAT THE PORTION OF THE FPL | | | EASEMENT, RECORDED IN ORB 1852, PG 1500, WHICH IS | | | LOCATED UNDER THE PROPOSED BUILDING SHALL HAS BEEN | | | VACATED. ADDITIONALLY, ANY UTILITIES THAT WERE IN THE | | | EASEMENT SHALL BE RELOCATED. | | | | | | 4) SHEETS A-1 AND A-2 STATE THAT THE OVERALL BUILDING | | | LENGTH IS 297'4", WHILE THE SURVEY, SITE PLAN AND | | | INDIVIDUAL PORTIONS OF THE BUILDING SHOWN 257'4". | | | | | | 5) IN ACCORDANCE WITH RESOLUTION NO. 288-11, ALL ROOF | | | MOUNTED AIR CONDITIONING, MECHANICAL EQUIPMENT, | | | SATELLITE DISHES, GENERATORS, ETC., SHALL BE SCREENED | | | FROM VIEW ON ALL SIDES BY A VISUALLY OPAQUE BARRIER | | | CONSISTENT WITH THE COLOR, CHARACTER AND ARCHITECTURAL | | | STYLE OF THE STRUCTURES OR EQUIVALENT LANDSCAPE | | | MATERIAL. THE HEIGHT OF THE OPAQUE BARRIER SHALL BE AS | | | REQUIRED TO PROVIDE AMPLE SCREENING. PROVIDE | | | VERIFICATION THAT THE ROOFTOP MECHANICAL EQUIPMENT WILL | | | BE SCREENED AS REQUIRED BY THE RESOLUTION FOR THE | | | SPECIFIC EQUIPMENT PROPOSED FOR INSTALLATION (EX. LINE | | | OF SIGHT OR ELEVATIONS WITH THE EQUIPMENT). | | | | | | 6) THE APPROVED ELEVATIONS FOR BUILDING 5/6 HAVE | | | CHANGED. THE BUILDING IS TALLER AND THE DOOR THAT WAS | | | AT THE BACK OF SUITE #1 HAS NOW BECOME A WINDOW. | | | REVISED ELEVATIONS ARE REQUIRED AS PART OF A MINOR | | | PLANNED DEVELOPMENT AMENDMENT TO SHOW THE ACTUAL | | | CONDITIONS. | | | | | | 7) THE REMOVAL OF THE DOOR REQUIRES THE RELOCATION OF | | | THE BICYCLE RACK AND PAD, AS THE RACK IS NO LONGER NEXT | | | TO AN INGRESS/EGRESS POINT TO THE BUILDING. THE | | | RELOCATED RACK AND PAD REQUIRES THE SITE PLAN AND | | | LANDSCAPE PLAN TO BE UPDATED AS PART OF A MINOR | | | AMENDMENT. PLEASE NOTE THAT THE BICYCLE RACK AND PAD IS | | | SHOWN (NINE FEET) WIDER THAT IT NEEDS TO BE (SEVEN | | | FEET), SO THERE IS AN OPPORTUNITY TO PLACE IT IN THE | | | TERMINAL LANDSCAPE ISLAND ON THE NORTHWEST CORNER OF | | | THE BUILDING. THE NEW BICYCLE PARKING LOCATION WOULD BE | | | IN TRACT A AND MAY NOT BE INCLUDED ON THIS PERMIT. THE | | | BICYCLE RACK AND PAD REQUIRE A SEPARATE PERMIT WITH THE | | | DETAILS OF BOTH FEATURES. | | | | | | 8) THE LANDSCAPE REQUIRES A SEPARATE PERMIT APPLICATION | | | FOR EACH PARCEL (TRACT A & TRACTS D/E) ON WHICH WORK IS | | | BEING DONE. THE SAME 2 COPIES OF THE LANDSCAPE PLAN MAY | | | BE USED FOR BOTH APPLICATIONS (SUBJECT TO CONCURRENT | | | SUBMITTAL). A COST ESTIMATE IS REQUIRED WITH THE | | | SUBMITTAL. | | | | | | 9) THE PLANS TO CONSTRUCT THE PARKING REQUIRED PRIOR TO | | | THE C.O. OF THE LAST PHASE I BUILDING (GENERALLY ALONG | | | THE SOUTH ACCESS DRIVE) SHALL BE INCLUDED ON A PARKING | | | LOT STRIPING PERMIT FOR TRACT A PRIOR TO ZONING | | | APPROVAL OF THIS PERMIT. STRIPING DETAILS FOR ALL | | | CONDITIONS SHALL BE PROVIDED. THE PARKING SHALL BE | | | INSTALLED PRIOR TO THE C.O. OF THIS BUILDING OR | | | BUILDING 7, WHICHEVER OCCURS LAST. | | | | | | 10) SIGNAGE AND AWNINGS REQUIRE SEPARATE PERMITS WITH | | | PLANS. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|
|