Plan Review Details - Permit 13060108
| Plan Review Stops For Permit 13060108 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2013-10-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-10-15 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-10-15 |
Time |
13:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2013-06-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-06-27 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-06-27 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2013-06-27 13:56:05 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. INSTALLATION SCHEDULE COMPLETED, BUT CONNECTION TYPE | | | NOT SPECIFIED. THIS SHOULD CORRELATE WITH ANCHOR | | | CHARTS. CONNECTION TYPE 8 WAS CIRCLED ON THE PRODUCT | | | APPROVAL, BUT THIS IS NOT ALLOWED FOR TAPCONS, SEE | | | ANCHOR CHARTS ON SHEET 5. | | | | | | 2. SHOW THE EMERGENCY MEANS OF ESCAPE, FBC R310.4. | | | INCLUDE THE ROOM DESIGNATION. | | | | | | NONE SHOWN. PLAN SHOWS PANELS OVER ALL OPENINGS, | | | INCLUDING TWO DOORS. REVISE. | | | | | | 3. OK | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-06-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-06-12 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-06-12 |
Time |
09:03 |
Sent To |
|
|
| Notes |
| 2013-06-12 09:04:01 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE | | | ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER | | | FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED. | | | THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET | | | AT | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | | INSTALLATION.PDF | | | | | | 2. SHOW THE EMERGENCY MEANS OF ESCAPE, FBC R310.4. | | | INCLUDE THE ROOM DESIGNATION. | | | | | | 3. PROVIDE A FLOOR PLAN SHOWING WHERE THE SHUTTERS WILL | | | BE INSTALLED AND PANEL SIZES WHICH CORRELATES WITH THE | | | INSTALLATION SCHEDULE, ITEM 1 ABOVE. FBC R301, FBC1609, | | | FBC*106. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-10-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-10-15 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-10-01 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2013-10-03 10:48:11 | SENT TO S HILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-06-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-06-27 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-06-19 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2013-06-20 09:15:26 | SENT TO S HILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-06-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-06-12 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-06-05 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2013-06-05 08:44:03 | INCOMING SENT TO MISC BOX # 1. JW |
|
|
|