Plan Review Details - Permit 13060093
| Plan Review Stops For Permit 13060093 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-06-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-06-27 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-06-27 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2013-06-27 11:01:21 | REVISION BUILDING REVIEW COMMENTS. | | | CODE: 2007 FBC. | | | | | | 1- LANDING AT DOOR NEEDS TO BE 36" MIN. AS REQUIRED BY | | | SEC. R311.4.3 OF 2007 FBC-RESIDENTIAL. DRAWINGS | | | SUBMITTED SHOW 33" LANDING WIDTH. THIS DOESN'T COMPLY. | | | | | | 2- NEED TO PROVIDE HANDRAILS FOR THE STAIRS AS REQUIRED | | | BY SEC. R311.5.6 OF 2007 FBC-RESIDENTIAL. | | | | | | 3- PROVIDE THE RISER AND TREAD DIMENSIONS TO VERIFY | | | COMPLIANCE WITH THE STAIR RATIO REQUIRED BY SEC. | | | R311.5.3.2 OF 2007 FBC-RESIDENTIAL. INFORMATION | | | SUBMITTED IS NOT CLEAR. | | | | | | 4- PROVIDE COMPLETE FRAMING DETAILS AND SPECIFICATIONS | | | FOR THE CONSTRUCTION OF THE DECK AND STAIRS. SPECIFY | | | ALL FOOTINGS, POSTS, BEAMS, JOIST SIZE AND SPACING, | | | CONNECTORS, ATTACHMENT TO THE WALL, AND DECK MATERIAL | | | AND SPECIFICATIONS. SEC. 106.1.1 CITY AMENDMENTS TO | | | FBC. | | | | | | 5- PLANS TO PROVIDE THE NAME AND SIGNATURE OF THE | | | PERSON RESPONSIBLE FOR THE DESIGN AS REQUIRED BY SEC. | | | 106.1 CITY AMENDMENTS TO FBC. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2013-06-14 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2013-06-14 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2013-06-10 |
Time |
11:08 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-06-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-06-27 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-06-05 |
Time |
13:05 |
Sent To |
|
|
| Notes |
| 2013-06-27 09:52:31 | REVISION RECEIVED ON MY DESK 6/26/13. JG. | | 2013-06-05 13:06:32 | INCOMING SENT TO ZONING BOX. JW |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2013-06-14 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2013-06-14 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2013-06-10 |
Time |
11:08 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy