Plan Review Details - Permit 13060084
Plan Review Stops For Permit 13060084
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2014-01-29 Cont ID  
Sent By jwitmer Date 2014-01-29 Time 12:25 Rev Time 0.00
Received By jwitmer Date 2014-01-29 Time 11:55 Sent To  
Notes
2014-01-29 12:10:42BUILDING PLAN REVIEW
 PERMIT: 13060084
 ADD: 6801 S DIXIE HWY
 CONT: S T WRIGHT BUILDERS, INC
 TEL: (561)385-2029
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 3RD REVIEW
 WED. JAN. 29/ 2014
 ACTION: BUILDING PROVISO
  
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 10) FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3
 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR
 CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)(B) WINDOWS SHEET A-3.01 NOTE 23 NEW DECORATIVE
 WINDOW FRAMES
 (31)((D) ROOFING PRODUCTS AND ASSEMBLIES
 MANSARD ROOFING TILE, SHEET A-3.02 NOTE 33
 MODIFIED ROOFING SHEET A-1.01 NEW MODIFIED ROOF
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
2013-12-16 11:04:47REVISED SHEETS SUBMITTED. JG.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-08-02 Cont ID  
Sent By jwitmer Date 2013-08-02 Time 09:02 Rev Time 0.00
Received By jwitmer Date 2013-08-02 Time 07:31 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-07-13 Cont ID  
Sent By jwitmer Date 2013-07-13 Time 09:14 Rev Time 0.00
Received By jwitmer Date 2013-07-13 Time 07:15 Sent To  
Notes
2013-07-13 09:14:37BUILDING PLAN REVIEW
 PERMIT: 13060084
 ADD: 6801 S DIXIE HWY
 CONT: S T WRIGHT BUILDERS, INC
 TEL: (561)385-2029
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
 THESE COMMENTS WERE
  
 1A) AD-1.01 & A-1.01 BOTH INDICATE WHAT APPEARS TO BE A
 ENCLOSED STORAGE ENCLOSURE (ROOFED OVER SCREEN ROOM),
 THE BUILDINGS OCCUPANT LOAD IS OVER 50 REQUIRING 2
 EXITS.
 2010 FBC-B 1014.2 (4) MEANS OF EGRESS SHALL NOT PASS
 THROUGH A STORAGE ROOM, CLOSETS OR SPACES USED FOR
 SIMILAR PURPOSES. NOTES 2 & 3 ON SHEET A-3.02 . THIS IS
 THE 2ND REQUIRED EXIT, IT CAN NOT BE USED FOR STORAGE,
 THIS IS A MORE HAZARDOUS OCCUPANCY.
  
 1B) 2010FBC-B 1014.2(2)AN EXIT ACCESS SHALL NOT PASS
 THROUGH A ROOM THAT CAN BE LOCKED TO PREVENT EGRESS.
 SHEET A-1.01 THE GATE LOCKED IN THE ENCLOSURE WITH
 PANIC HARDWARE, PLEASE PROVIDE MANUFACTURERS SPEC SHEET
 FOR PANIC HARDWARE BEING INSTALLED ON FOR THIS TYPE OF
 APPLICATION.
  
 2-4) COMPLIED.
  
 5) SHEET A-4.01 DECORATIVE BUILD-OUT DETAILS # 3 A-B
 AND DETIAL 5 A-B DO NOT MATCH UP WITH THE STRUCTURAL
 DETAILS FOUND ON S-4.01 PLEASE UPDATE THE STRUCTURAL
 PLANS AS TO THE ARCHITECTURAL DETAILS. DISCREPANCIES IN
 PLANS ADDITIONAL INFORMATION IS REQUIED. 107.2.1.3.
  
 6-7) COMPLIED.
  
 8) SHEET S-4.01 WALL SECTION # 2 & 3 & S-5.01 WALL
 SECTIONS 4 & 5 INDICATE THE USE OF STUCCO MISSING
 INFORMATION ON THE REQUIRED BOND BREAK PER SECTION
 1404.2.1 2010 FBC-B.
  
 9) THE SHEET A-1.01 INDICATES A NEW MODIFIED BITUMEN
 ROOFING SYSTEM, NO PRODUCT APPROVALS WERE SUBMITTED
 WITH THIS REVIEW:
 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 10) FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3
 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR
 CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)((D) ROOFING PRODUCTS AND ASSEMBLIES
  
 11) STRUCTURAL SHEET S-7.01 PROVIDES THE WIND DESIGN
 CRITERIA, BUT THE ROOFING PRESSURES ARE MISSING FOR
 ROOF ZONES 1 & 2. 2010 FBC-B 1609.4.4.1 COMPONENTS &
 CLADDING.
  
 12) 2010 WPB ADMINISTRTIVE CODE 110.3.9(7) FOR
 BUILDINGS AND STRUCTURES OF UNUSUAL DESIGN OR METHODS
 OF CONSTRUCTION. CONTACT KEN CONRAD AT 561-805-6666 FOR
 RESIDENT INSPECTOR REQUIREMENTS.
 THIS BUILDING HAS STRUCTURAL STEEL THAT WILL REQUIRE
 EITHER BOLTING OR WELDING OF CONNENCTION REQUIRING A
 ON-SITE INSPECTOR. 110.3.9 OTHER INSPECTIONS SERVICES.
 THE BUILDING OFFICIAL MAY MAKE, OR CAUSE TO BE MADE
 BY OTHERS, THE INSPECTIONS REQUIRED BY SECTION 109.
 HE/SHE MAY ACCEPT REPORTS OF INSPECTORS OF RECOGNIZED
 INSPECTION SERVICES, PROVIDED THAT AFTER INVESTIGATION
 HE/SHE IS SATISFIED AS TO THEIR QUALIFICATIONS AND
 RELIABILITY. A CERTIFICATE CALLED FOR BY ANY PROVISION
 OF THE TECHNICAL CODES SHALL NOT BE BASED ON SUCH
 REPORTS UNLESS THE SAME ARE IN WRITING AND CERTIFIED BY
 A RESPONSIBLE OFFICER OF SUCH SERVICE.
  
 SUCH INSPECTORS SHALL BE ADEQUATELY PRESENT AT TIMES
 WORK IS UNDERWAY ON THE STRUCTURAL ELEMENTS OF THE
 BUILDING. SUCH INSPECTORS SHALL BE A REGISTERED
 ARCHITECT, OR ENGINEER, OR A PERSON LICENSED UNDER
 CHAPTER 468, PART XII, FLORIDA STATUTES. SUCH
 INSPECTORS SHALL SUBMIT WEEKLY PROGRESS REPORTS
 INCLUDING THE DAILY INSPECTIONS TO THE BUILDING
 OFFICIAL, AND INCLUDING A CODE COMPLIANCE OPINION OF
 THE RESIDENT INSPECTOR.
 AT THE COMPLETION OF THE CONSTRUCTION WORK OR PROJECT,
 SUCH INSPECTORS SHALL SUBMIT A CERTIFICATE OF
 COMPLIANCE TO THE BUILDING OFFICIAL, STATING THAT THE
 WORK WAS DONE IN COMPLIANCE WITH THIS CODE AND IN
 ACCORDANCE WITH THE PERMITTED DRAWING. FINAL INSPECTION
 SHALL BE MADE BY THE BUILDING OFFICIAL BEFORE A
 CERTIFICATE OF OCCUPANCY OR CERTIFICATE OF COMPLETION
 IS ISSUED; AND CONFIRMATION INSPECTIONS MAY BE MADE AT
 ANY TIME TO MONITOR ACTIVITIES AND RESIDENT INSPECTORS.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2014-03-03 Cont ID  
Sent By albarran Date 2014-03-03 Time 15:48 Rev Time 0.00
Received By albarran Date 2014-03-03 Time 15:16 Sent To I
Notes
2014-03-03 16:08:00IMPORTANT PROVISO NOTICE:
 THE ATTACHED CONDITIONS AND/OR RESTRICTIONS HAVE BEEN
 MADE A PART OF THE CONDITIONAL APPROVAL OF THIS PERMIT
 OR PLANS BY THE ELECTRICAL PLANS EXAMINER:
 FBC-E 505.2.4 EXTERIOR LIGHTING: ALL EXTERIOR LIGHTING
 NOT EXEMPTED BY 505.1 SHALL HAVE AUTOMATIC CONTROLS TO
 TURN OFF AT DAYLIGHT OR WHEN NOT REQUIRED. CONTROLS
 SHALL BE PHOTOSENSOR & TIME CLOCK OR ASTRONOMICAL TIME
 SWITCH.
 AS PER NEC THE INTERIOR OF AN UNDERGROUND (OR IN
 CONCRETE SLAB) RACEWAY SHALL BE CONSIDERED A WET
 LOCATION; ALL CONDUCTORS WITHIN THE RACEWAY SHALL BE
 LISTED ACCORDINGLY.

Review Stop E ELECTRICAL
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By skennedy Date 2014-02-28 Time 10:43 Sent To  
Notes
2014-02-28 10:43:55SENT TO MALBARRAN DESK. THERE IS APPARENTLY NO SET OF
 ELECTRICAL PLANS IN THE FIELD OR WITH THE RECORD SET,
 ALTHOUGH THERE IS RECORD OF ELECTRICAL REVIEW. PLEASE
 REVIEW BY LOOKING AT THE PLANS ON FILENET.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2013-09-04 Cont ID  
Sent By dharvey Date 2013-09-04 Time 18:12 Rev Time 0.00
Received By dharvey Date 2013-09-04 Time 18:12 Sent To  
Notes
2013-09-04 18:13:382ND REVIEW - 9-4-13
  
 DRAWINGS REVIEWED AND APPROVED BY ROBERT LECKY,
 7-23-12.
 NO FUTHER REVIEW WAS DONE AT THIS TIME...
 VB

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2013-07-22 Cont ID  
Sent By lphilmor Date 2013-07-22 Time 07:46 Rev Time 0.00
Received By lphilmor Date 2013-07-18 Time 13:09 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
2014-03-03 16:08:42SAK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-01-29 Cont ID  
Sent By jwitmer Date 2014-01-29 Time 12:26 Rev Time 0.00
Received By jwitmer Date 2013-12-16 Time 10:58 Sent To  
Notes
2013-12-16 10:58:33RESUBMITTAL SENT TO ZONING SHELF FOR J. ROACH'S REVIEW.
 JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-09-04 Cont ID  
Sent By dharvey Date 2013-09-04 Time 18:13 Rev Time 0.00
Received By dharvey Date 2013-09-04 Time 18:13 Sent To  
Notes
2013-06-05 10:19:59INCOMING SENT TO C-04 BOX. JW

Review Stop Z ZONING
Rev No 2 Status P Date 2014-01-27 Cont ID  
Sent By jroach Date 2014-01-27 Time 11:44 Rev Time 0.00
Received By jroach Date 2013-12-16 Time 12:17 Sent To B
Notes
2013-12-16 12:18:0012/16/13 - ZONING RECEIVED. SENT TO JR FOR REVIEW. LL

Review Stop Z ZONING
Rev No 1 Status F Date 2013-09-04 Cont ID  
Sent By jroach Date 2013-09-04 Time 17:48 Rev Time 0.00
Received By jroach Date 2013-08-05 Time 15:22 Sent To  
Notes
2013-09-04 17:50:44ZONING PLAN REVIEW
 ___________________________________________
  
 DATE OF REVIEW: 09.04.2013
 PERMIT NO.: 13060084
 ADDRESS: 6801 SOUTH DIXIE HIGHWAY
 CONTRACTOR/CONTACT: STEPHEN WRIGHT
 TELEPHONE NO.: 561.385.2029
 SCOPE OF REVIEW: EXTERIOR ALTERATIONS TO EXISTING
 BUILDING.
 ___________________________________________
  
 REVIEW STATUS: FAILED
 ___________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. IT APPEARS THAT THE DECORATIVE BANDING, COLUMNS,
 ETC. ARE EXTENDING OUT FROM THE FACADE, ENCROACHING
 INTO THE FDOT RIGHT-OF-WAY.
 ___________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN ROACH, SENIOR PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 PHONE: 561.822.1435
 FAX: 561.822.1460
  
 EMAIL: [email protected]
  
 WWW.CITYOFWPB.COM
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved