| 2013-06-05 14:34:34 | BUILDING PLAN REVIEW |
| | PERMIT: 13060078 |
| | ADD: 614 SUNSET |
| | CONT: WATERPROOFING & ROOFING DESIGN |
| | TEL: (561)741-8919 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, RESIDNTIAL. |
| | |
| | 1STREVIEW |
| | DATE: JUNE 05/2013 |
| | ACTION: DENIED |
| | |
| | 1) ROOFING NOTE # 7 INDICATES REMOVE & REPLACE FRONT |
| | TILE ROOF AREA WITH THE SAME CLAY TILE. THE CONTRACTOR |
| | HAS NOT PROVIDED WHAT TYPE OF FASTENERS WILL BE USED IN |
| | THE REINSTALLATION OF THE CLAY TILE. |
| | |
| | 2) CLAY TILE R905.3.3 UNDERLAYMENT. |
| | REQUIRED UNDERLAYMENT SHALL CONFORM WITH ASTM D 226, |
| | TYPE II; ASTM D 2626, TYPE II; ASTM D 1970 OR ASTM D |
| | 6380, CLASS M AND SHALL BE INSTALLED IN ACCORDANCE WITH |
| | FRSA/TRI 07320 WHERE THE VASD IS DETERMINED IN |
| | ACCORDANCE WITH SECTION R301.2.1.3 OR THE |
| | RECOMMENDATIONS OF RAS 118, 119 OR 120. |
| | |
| | R905.3.3.1 SLOPE AND UNDERLAYMENT REQUIREMENTS. |
| | REFER TO FRSA/TRI 07320 WHERE THE VASD IS DETERMINED IN |
| | ACCORDANCE WITH SECTION R301.2.1.3 OR RAS 118, 119 OR |
| | 120 FOR UNDERLAYMENT AND SLOPE REQUIREMENTS FOR |
| | SPECIFIC ROOF TILE SYSTEMS. |
| | |
| | NOTE IF THE CLAY TILE ARE HISTORIC CUBAN TILE THEN 2010 |
| | EXIST BLDG CODE SECTION 1107 WOULD APPLY. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |