Plan Review Details - Permit 13060014
| Plan Review Stops For Permit 13060014 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2013-10-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-10-26 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-10-26 |
Time |
14:43 |
Sent To |
|
|
| Notes |
| 2013-10-26 14:43:59 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | SAME PLAN SUBMITTED. SEE FIRST REVIEW: | | | | | | 1. PROVIDE A LEGIBLE PLAN TO PROVIDE THE FOLLOWING | | | INFORMATION: | | | | | | TOTAL NUMBER OF PARKING SPACES | | | NUMBER OF ACCESSIBLE SPACES | | | LOCATION OF ACCESSIBLE ENTRANCES | | | LOCATION OF ACCESSIBLE SPACES AND ACCESS AISLES | | | SHOW ACCESSIBLE ROUTE FROM PUBLIC WAY | | | ACCESSIBLE ROUTE FROM ACCESSIBLE SPACE TO ACCESSIBLE | | | ENTRANCE | | | | | | SEE FBC 2010 ACCESSIBLITY 202.3 (ALTERATIONS), 208.2 | | | (PARKING SPACES), 502 (PARKING SPACES), 206 (ACCESSIBLE | | | ROUTE). | | | | | | YOU MAY FIND THE FOLLOWING DOCUMENT USEFUL, | | | PARTICULARLY THE INTRODUCTION: "WHEN A BUSINESS | | | RESTRIPES A PARKING LOT, IT MUST PROVIDE ACCESSIBLE | | | PARKING SPACES AS REQUIRED BY THE ADA STANDARDS FOR | | | ACCESSIBLE DESIGN." | | | | | | HTTP://WWW.ADA.GOV/RESTRIPE.HTM | | | | | | 2. FBC 2010 ACCESSIBILITY ADVISORY 502.3, WHERE THE | | | ACCESSIBLE ROUTE MUST CROSS VEHICULAR TRAFFIC LANES, | | | MARKED CROSSINGS ENHANCE PEDESTRIAN SAFETY; PLEASE | | | INDICATE LOCATION ON PLAN. | | | | | | 3. THE INDIVIDUAL TAKING RESPONSIBILITY SHALL PROVIDE | | | THEIR PRINTED NAME AND SIGNATURE ON THE PLAN, FBC 107. | | | | | | 4. IT APPEARS THAT THE ACCESS AISLE IS ON AN ADJACENT | | | PROPERTY. THIS REQUIRES A SEPARATE PERMIT APPLICATION | | | AS IT IS A DIFFERENT PARCEL. HOWEVER, SEE ZONING | | | COMMENTS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-06-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-06-27 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-06-27 |
Time |
16:54 |
Sent To |
|
|
| Notes |
| 2013-06-27 16:56:19 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. PROVIDE A LEGIBLE PLAN TO PROVIDE THE FOLLOWING | | | INFORMATION: | | | | | | TOTAL NUMBER OF PARKING SPACES | | | NUMBER OF ACCESSIBLE SPACES | | | LOCATION OF ACCESSIBLE ENTRANCES | | | LOCATION OF ACCESSIBLE SPACES AND ACCESS AISLES | | | SHOW ACCESSIBLE ROUTE FROM PUBLIC WAY | | | ACCESSIBLE ROUTE FROM ACCESSIBLE SPACE TO ACCESSIBLE | | | ENTRANCE | | | | | | SEE FBC 2010 ACCESSIBLITY 202.3 (ALTERATIONS), 208.2 | | | (PARKING SPACES), 502 (PARKING SPACES), 206 (ACCESSIBLE | | | ROUTE). | | | | | | YOU MAY FIND THE FOLLOWING DOCUMENT USEFUL, | | | PARTICULARLY THE INTRODUCTION: "WHEN A BUSINESS | | | RESTRIPES A PARKING LOT, IT MUST PROVIDE ACCESSIBLE | | | PARKING SPACES AS REQUIRED BY THE ADA STANDARDS FOR | | | ACCESSIBLE DESIGN." | | | | | | HTTP://WWW.ADA.GOV/RESTRIPE.HTM | | | | | | 2. FBC 2010 ACCESSIBILITY ADVISORY 502.3, WHERE THE | | | ACCESSIBLE ROUTE MUST CROSS VEHICULAR TRAFFIC LANES, | | | MARKED CROSSINGS ENHANCE PEDESTRIAN SAFETY; PLEASE | | | INDICATE LOCATION ON PLAN. | | | | | | 3. THE INDIVIDUAL TAKING RESPONSIBILITY SHALL PROVIDE | | | THEIR PRINTED NAME AND SIGNATURE ON THE PLAN, FBC 107. | | | | | | 4. IT APPEARS THAT THE ACCESS AISLE IS ON AN ADJACENT | | | PROPERTY. THIS REQUIRES A SEPARATE PERMIT APPLICATION | | | AS IT IS A DIFFERENT PARCEL. HOWEVER, SEE ZONING | | | COMMENTS. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2013-10-20 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2013-10-20 |
Time |
|
Rev Time |
0.25 |
| Received By |
mgonzale |
Date |
2013-10-20 |
Time |
|
Sent To |
B |
|
| Notes |
| 2013-10-20 21:28:43 | FAILED: | | | | | | 1. STRIPING IMPROVEMENT IS SHOWN ON LOT TO THE WEST. | | | 2. DRAWING SHOWING PARKING PACES DOES NOT SHOW CORRECT | | | SPACING OF PARKINGS. | | | | | | MANUEL JULIAN GONZALEZ | | | ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES AND PUBLIC WORKS DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2013-06-25 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2013-06-25 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2013-06-25 |
Time |
|
Sent To |
I |
|
| Notes |
| 2013-06-25 12:00:44 | NO DIMENSIONS | | | | | | NO PARKING DETAILS | | | | | | ADA STRIPING ENCROACHES INTO NEIGHBOR PROPERTY. | | | | | | SHOW CATCH BASINS (STORMWATER) | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-10-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-10-26 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-09-16 |
Time |
07:48 |
Sent To |
|
|
| Notes |
| 2013-09-17 07:48:49 | INCOMING -CHANGE SCOPE OF WORK, SENT TO ZONING BOX. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-09-17 |
Time |
07:47 |
Sent To |
|
|
| Notes |
| 2013-10-21 08:49:58 | 10/21 TO SH DESK | | | | | 2013-09-11 08:53:58 | INCOMING SENT TO ZONING BOX. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-06-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-06-27 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-06-03 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2013-06-25 13:31:30 | 6/25 TO MISC 3 | | | | | 2013-06-04 07:54:39 | SENT TO ZONING BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2013-09-19 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2013-09-19 |
Time |
15:15 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2013-09-17 |
Time |
11:14 |
Sent To |
ENG |
|
| Notes |
| 2013-09-19 15:18:28 | FAILED - COMMENTS UPDATED BASED ON SEALCOAT AND NOT | | | ASPHALT OVERLAY. | | | | | | 1) REPEAT COMMENT: THE LASTEST APPROVED SITE PLAN FOR | | | THE PROPERTY, APPROVED FEBRUARY, 21, 1985, SHOWS A FIVE | | | (5) FOOT WIDE TERMINAL LANDSCAPE ISLAND ON THE WEST END | | | OF THE SOUTHERN ROW OF PARKING SPACES. STAFF WAS UNABLE | | | TO FIND A PERMIT THAT AUTHORIZED THE REMOVAL OF THE | | | TERMINAL ISLAND; THEREFORE, THE TERMINAL ISLAND, AND | | | THE MISSING LANDSCAPE IS REQUIRED TO BE REPLACED. | | | | | | 2) REPEAT COMMENT: ALL OF THE FEATURES OF THE PARKING | | | LOT, TO INCLUDE THE ACCESS AILSE TO THE HANDICAP | | | PARKING SPACE ARE REQUIRED TO BE KEPT ON SITE. THE | | | ACCESS AISLE MAY NOT ENCROACH ONTO THE NEIGHBORING | | | PROPERTY. | | | | | | 3) REPEAT COMMENT: THE DIMENSION BETWEEN THE EASTERN | | | CURB LINE FOR THE SOUTHERN PARKING ROW PERMITS EIGHT | | | (8) PARKING SPACES, PLUS THE 12 FOOT WIDE ADA PARKING | | | SPACE AND FIVE (5) FOOT WIDE ACCESS AISLE AND THE | | | LANDSCAPE ISLAND. | | | | | | 4) REPEAT COMMENT: THE TWO (2) PARKING SPACES AGAINST | | | THE SOUTH SIDE OF THE BUILDING ARE NOT APPROVED PARKING | | | SPACES AND MAY NOT BE REPAINTED. THE DRIVE AISLIE IS | | | REQUIRED TO BE 24 FEET WIDE, WHICH LEAVES EITHER FIVE | | | (5) FEET OR SEVEN (7) OF WIDTH FOR THE PROPOSED PARKING | | | SPACES. THE CITY'S ZONING AND LAND DEVELPMENT | | | REGULATIONS REQUIRE 8.5 FEEM MINIMIUM FOR PARALLEL | | | PARKING SPACES. THE TWO FOOT WIDTH VARIATION IS DUE TO | | | THE 90 DEGREE PARKING SPACES APPROVED AT 20 FEET IN | | | DEPTH VERSUS THE CITY MINIMUM REQUIRDED DEPTH OF 18 | | | FEET. | | | | | | 5) REPEAT COMMENT: NO DIMENSIONS ARE GIVEN FOR THE | | | PROPOSED PARKING SPACES. | | | | | | 6) REPEAT COMMENT: NO DETAILS, SHOWING THE THAT PARKING | | | WILL COMPLY WITH CITY OF WEST PALM BEACH STRIPING | | | STANDARDS, WERE PROVIDED. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | | | 2013-09-17 11:15:04 | ZONING RECEIVED. ROUTED TO ES FOR REVIEW. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2013-06-18 |
|
|
Cont ID |
|
| Sent By |
escheird |
Date |
2013-06-17 |
Time |
11:53 |
Rev Time |
2.00 |
| Received By |
eschneid |
Date |
2013-06-10 |
Time |
11:07 |
Sent To |
ENG |
|
| Notes |
| 2013-06-18 14:28:00 | FAILED | | | | | | 1) THE LASTEST APPROVED SITE PLAN FOR THE PROPERTY, | | | APPROVED FEBRUARY, 21, 1985, SHOWS A FIVE (5) FOOT WIDE | | | TERMINAL LANDSCAPE ISLAND ON THE WEST END OF THE | | | SOUTHERN ROW OF PARKING SPACES. STAFF WAS UNABLE TO | | | FIND A PERMIT THAT AUTHORIZED THE REMOVAL OF THE | | | TERMINAL ISLAND; THEREFORE, THE TERMINAL ISLAND, AND | | | THE MISSING LANDSCAPE IS REQUIRED TO BE REPLACED. | | | | | | 2) IN ADDITION TO COMMENT NO. 1 ABOVE, THE PERMIT IS | | | FOR AN ASPHALT OVERLAY, WHICH THE CITY CONSIDERS A NEW | | | PARKING LOT, AND AS SUCH, THE REQUIRED PARKING LOT | | | LANDSCAPE IS REQUIED. THIS INCLUDES TERMINAL ISLANDS | | | AND PERIMETER BUFFERS. | | | | | | 3) ALL OF THE FEATURES OF THE PARKING LOT, TO INCLUDE | | | THE ACCESS AILSE TO THE HANDICAP PARKING SPACE ARE | | | REQUIRED TO BE KEPT ON SITE. THE ACCESS AISLE MAY NOT | | | ENCROACH ONTO THE NEIGHBORING PROPERTY. | | | | | | 4) THE DIMENSION BETWEEN THE EASTERN CURB LINE FOR THE | | | SOUTHERN PARKING ROW PERMITS EIGHT (8) PARKING SPACES, | | | PLUS THE 12 FOOT WIDE ADA PARKING SPACE AND FIVE (5) | | | FOOT WIDE ACCESS AISLE AND THE LANDSCAPE ISLAND. | | | | | | 5) THE TWO (2) PARKING SPACES AGAINST THE SOUTH SIDE OF | | | THE BUILDING ARE NOT APPROVED PARKING SPACES AND MAY | | | NOT BE REPAINTED. THE DRIVE AISLIE IS REQUIRED TO BE 24 | | | FEET WIDE, WHICH LEAVES EITHER FIVE (5) FEET OR SEVEN | | | (7) OF WIDTH FOR THE PROPOSED PARKING SPACES. THE | | | CITY'S ZONING AND LAND DEVELPMENT REGULATIONS REQUIRE | | | 8.5 FEEM MINIMIUM FOR PARALLEL PARKING SPACES. THE TWO | | | FOOT WIDTH VARIATION IS DUE TO THE 90 DEGREE PARKING | | | SPACES APPROVED AT 20 FEET IN DEPTH VERSUS THE CITY | | | MINIMUM REQUIRDED DEPTH OF 18 FEET. | | | | | | 6) NO DIMENSIONS ARE GIVEN FOR THE PROPOSED PARKING | | | SPACES. | | | | | | 7) NO DETAILS, SHOWING THE THAT PARKING WILL COMPLY | | | WITH CITY OF WEST PALM BEACH STRIPING STANDARDS, WERE | | | PROVIDED. | | | | | | 8) THE LANDSCACPE INSTALLATION WILL REQUIRE A LANDSCAPE | | | PERMIT, ACCOMPANIED BY A LANDSCAPE PLAN. THE PARKING | | | LOT ISLANDS WILL REQUIRE ONE TREE EACH AND THE | | | PERIMETER LANDSCAPE BUFFERS WILL REQUIRE A TREE EVERY | | | 30 FEET. PLEASE NOTE THAT THERE IS NO PERMIT ON FILE | | | FOR THE REMOVAL OF THE NORTHERN LANDSCAPE BUFFER | | | (ADJACENT TO THE SEATING AREA). THIS WILL NEED TO BE | | | REPLACED. | | | | | | 9) DUE TO THE CONSTURCTION OF THE NEW PARKING LOT, THE | | | REQUIRED BICYCLE PARKING SPACE IS REQUIRED. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | |
|
|
|