| 2014-02-22 10:24:07 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | COMMENT FROM PREVIOUS LIST: | | | | | | 1. PLANS SUBMITTED ARE NOT SIGNED, SEALED AND DATED, FS | | | 481. | | | | | | SHEET SP1 DATED 1/18/12 PREPARED BY JON E SCHMIDT AND | | | ASSOCIATES IS NOT SIGNED, SEALED AND DATED AS REQUIRED | | | BY FLORIDA STATUTE 481. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2013-10-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-10-26 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-10-26 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2013-10-26 16:09:05 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. PLANS SUBMITTED ARE NOT SIGNED, SEALED AND DATED, FS | | | 481. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-08-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-08-13 |
Time |
17:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-08-13 |
Time |
17:09 |
Sent To |
ENG |
|
| Notes |
| 2013-08-13 17:12:43 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. REVISE PLAN TO PROVIDE THE FOLLOWING INFORMATION: | | | | | | TOTAL NUMBER OF PARKING SPACES | | | NUMBER OF ACCESSIBLE SPACES | | | LOCATION OF ACCESSIBLE ENTRANCES | | | ACCESSIBLE SPACE DOES NOT SHOW THE REQUIRED ACCESS | | | AISLE | | | SHOW ACCESSIBLE ROUTE FROM PUBLIC WAY | | | ACCESSIBLE ROUTE FROM ACCESSIBLE SPACE TO ACCESSIBLE | | | ENTRANCE, INCLUDING DIMENSIONS | | | | | | SEE FBC 2010 ACCESSIBLITY 202.3 (ALTERATIONS), 208.2 | | | (PARKING SPACES), 502 (PARKING SPACES), 206 (ACCESSIBLE | | | ROUTE). | | | | | | YOU MAY FIND THE FOLLOWING DOCUMENT USEFUL, | | | PARTICULARLY THE INTRODUCTION: "WHEN A BUSINESS | | | RESTRIPES A PARKING LOT, IT MUST PROVIDE ACCESSIBLE | | | PARKING SPACES AS REQUIRED BY THE ADA STANDARDS FOR | | | ACCESSIBLE DESIGN." | | | | | | HTTP://WWW.ADA.GOV/RESTRIPE.HTM | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
4 |
Status |
P |
Date |
2014-03-24 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2014-03-24 |
Time |
|
Rev Time |
0.25 |
| Received By |
mgonzale |
Date |
2014-03-24 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2014-01-24 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2014-01-24 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2014-01-24 |
Time |
|
Sent To |
B |
|
| Notes |
| 2014-01-24 09:45:29 | PASSED |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2013-10-22 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2013-10-22 |
Time |
|
Rev Time |
1.00 |
| Received By |
|
Date |
2013-10-22 |
Time |
|
Sent To |
B |
|
| Notes |
| 2013-10-22 17:06:38 | PLEASE RESPOND TO COMMENTS IN WRITING: | | | #1 NO EXISTING OR PROPOSED DRAINAGE IS SHOWN: | | | TYPICAL SURFACE WATER CRITERIA: SFWMD, APPLICANTS TREAT | | | FIRST INCH OF RUNOFF OR 2 1/2 TIMES THE IMPERVIOUS | | | AREA, WHICH EVER IS GREATER. | | | | | | #2 PROVIDE PROPOSED PERVIOUS AND IMPERVIOUS | | | CALCULATIONS. THESE FIGURES WILL BE USED TO UPDATE | | | STORM WATER ACCOUNT. | | | | | | NOTE: ABSENCE OF STORM WATER | | | IN MANY PARTS OF THE CITY THE ABSENCE OF ANY STORMWATER | | | BMP (STORMWATER BEST MANAGEMENT PRACTICES) IN SITES | | | ALLOWS THE BOTH THE WATER VOLUME AND | | | CONTAMINANT/POLLUTANT LOAD TO ENTER OUR SYSTEM | | | UNTREATED. WHILE WE BELIEVE OUR EXISTING SYSTEM IS | | | SUFFICIENT TO SERVICE THE STORMWATER VOLUME FOR YOUR | | | PROPOSED USE; HOWEVER WE RECOGNIZE THAT THE FIRST FLUSH | | | FROM THE IMPERVIOUS AREA CONTAINS 90% OF THE | | | CONTAMINANT/POLLUTANT LOAD FROM RAIN EVENTS AND THIS | | | LOADING IS TRANSFERRED TO THE CITY?S STORMWATER SYSTEM. | | | ACCORDINGLY, THE CITY HAS THE AUTHORITY TO IMPOSE | | | STORMWATER BMP?S ON THE ENTIRE SITE WITH OR WITHOUT THE | | | PROGRESSION OF THE PROPOSED WORK. HOWEVER, IN | | | CONSIDERATION OF THE SCOPE OF THE PROPOSED | | | IMPROVEMENTS, THE CITY HAS THE AUTHORITY TO THROTTLE | | | IMPLEMENTATION OF BMP?S. IN THIS CASE, OUR | | | RECOMMENDATION IS THAT YOU AS THE PROPERTY OWNER SHALL | | | DESIGN AND MODIFY THE EXISTING STORMWATER | | | INFRASTRUCTURE SERVING THE EXISTING PAVED AREA THAT HAS | | | BEEN IDENTIFIED BY THE PLANNING AND ZONING DEPARTMENT | | | AS REQUIRED SUPPORTING YOUR CONSTRUCTION. | | | ANY MODIFICATION SHALL INCORPORATE STORMWATER BMP?S | | | SUFFICIENT TO DETAIN THE FIRST FLUSH FROM THE | | | REFERENCED IMPERVIOUS AREA. OWNER MAY PROPOSE AN | | | ISOLATED SYSTEM THAT DETAINS AND PERCOLATES. PLEASE | | | REFER TO THE SOUTH FLORIDA WATER MANAGEMENT DISTRICT | | | MANUAL, IT?S A GOOD GUIDE TO SEE THE OPTIONS THAT MAY | | | WORK WITH YOUR SITE. PLEASE LOOK AT THE OPTIONS FOR | | | | | | NONSTRUCTURAL BMP?S AND STRUCTURAL BMP?S. WE BELIEVE | | | ANY OF THESE MODIFICATIONS REFLECT REASONABLE | | | IMPROVEMENTS TO THE EXISTING CONDITIONS AND ARE | | | CONSISTENT WITH PRACTICES OF BOTH THE CITY AND SOUTH | | | FLORIDAWATER MANAGEMENT DISTRICT. | | | HTTP://WWW.SFWMD.GOV/PORTAL/PAGE/PORTAL/XREPOSITORY/SFW | | | MD_REPOSITORY_PDF/BMP_MANUAL.PDF | | | | | | MANUEL JULIAN GONZALEZ | | | ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES AND PUBLIC WORKS DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822?1200 | | | DIRECT: (561) 494?1085 | | | FAX: (561) 494?1116 | | | MOBILE: (561) 644?7301 | | | EMAIL: [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2013-08-14 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2013-08-14 |
Time |
|
Rev Time |
1.00 |
| Received By |
|
Date |
2013-08-14 |
Time |
|
Sent To |
|
|
| Notes |
| 2013-08-14 06:57:35 | #1 PROVIDE EXPLANATION ON HOW STORM WATER IS MANAGED BY | | | YOUR SITE? PROVIDE TOTAL SITE AREA, PERVIOUS AREA, AND | | | IMPERVIOUS AREAS IN SQUARE FEET. | | | | | | #2 SHOW LOCATION OF WATER METER AND BACKFLOW PREVENTER. | | | IF NO BACKFLOW IS PRESENT YOU WILL NEED TO INSTALL ONE. | | | | | | #3 DUMPSTER AREA DOES NOT SHOW DIMENSIONS. PROVIDE A | | | DETAIL OR YOU MAY INCLUDE THE CITY OF WPB STANDARD | | | DUMPSTER DETAIL. | | | HTTP://WPB.ORG/ENGINEERING/ENGINEERING-SERVICES/ENGINEE | | | RING-STANDARDS/ | | | | | | #4 PROVIDE NOTE OR SHOW SIDEWALK ALONG ORTEGA THAT | | | PROVIDES ACCESS TO YOUR ADA ENTRANCE. | | | | | | #5 DUMPSTER AREA ENTRANCE IS NOT ANGLED FOR EASY | | | ACCESS. PROVIDE NOTE ON PLAN: DUMPSTER WILL BE ROLLED | | | OUT AT CUSTOMER'S EXPENSE IF AND WHEN DUMPSTER IS NOT | | | ACCESSIBLE FOR PICK-UP. | | | | | | #6 IF SITE PLAN IS BEING REVISED, PROVIDE A COPY. | | | | | | #7 IF WATER AND SEWER ARE NEW YOU WILL HAVE TO SUBMIT | | | PLANS DIRECTLY TO CITY OF WPB ENGINEERING SERVICES FOR | | | THE WORK IN THE ROW. CITY OF WPB STANDARD DETAILS MUST | | | BE SHOWN ON PLANS. | | | ROAD RESTORATION, WATER SERVICE DETAIL, SEWER SERVICE | | | DETAILS, ETC. (THE WEB SITE ADDRESS BELOW WILL TAKE YOU | | | TO ENGINEERING SERVICES FORMS. | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | | | MANUEL JULIAN GONZALEZ | | | ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES AND PUBLIC WORKS DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2014-03-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-03-25 |
Time |
18:49 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-03-10 |
Time |
11:01 |
Sent To |
|
|
| Notes |
| 2014-03-18 10:55:57 | 3/18 TO ZONING | | | | | 2014-03-11 10:54:47 | SENT TO SHILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-02-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-02-22 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-01-06 |
Time |
08:21 |
Sent To |
|
|
| Notes |
| 2014-01-07 08:34:29 | SENT TO ZONING BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-10-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-10-26 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-10-02 |
Time |
17:22 |
Sent To |
|
|
| Notes |
| 2013-10-23 18:15:23 | 10/23 TO SH DESK | | 2013-10-02 17:22:28 | INCOMING SENT TO ZONING BOX. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-08-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-08-14 |
Time |
07:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-05-31 |
Time |
17:21 |
Sent To |
|
|
| Notes |
| 2013-05-31 17:21:11 | TO ZONING | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2014-03-20 |
|
|
Cont ID |
|
| Sent By |
JRoach |
Date |
2014-03-20 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2014-03-18 |
Time |
12:25 |
Sent To |
ENG |
|
| Notes |
| 2014-03-18 12:25:31 | 3/18/14 ZONING RESUB,SENT TO JR.SG |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2014-01-23 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2014-01-23 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2014-01-08 |
Time |
13:10 |
Sent To |
ENG |
|
| Notes |
| 2014-01-08 13:10:57 | 1/8/14 - ZONING RECEIVED. SENT TO JR FOR REVIEW. LL |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2013-10-09 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2013-10-09 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2013-10-09 |
Time |
08:36 |
Sent To |
ENG |
|
| Notes |
| 2013-10-09 08:37:18 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 10.09.2013 | | | PERMIT NO.: 13051110 | | | ADDRESS: 1220 ORTEGA ROAD | | | CONTRACTOR/CONTACT: WILBUR HOBGOOD | | | TELEPHONE NO.: 561.691.9686 | | | SCOPE OF REVIEW: PARKING LOT AND SITE WORK AS PART OF | | | NEW ADDITION. | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. TWO (2) COPIES OF A CURRENT AND ACCURATE SURVEY | | | SHALL BE PROVIDED. | | | | | | 2. ACCORDING TO THE PERMIT APPLICATIONS SUBMITTED, THE | | | VALUE OF THE PROPOSED CONSTRUCTION ON THE SITE EXCEEDS | | | 50 PERCENT OF THE VALUE OF THE STRUCTURE. THEREFORE, | | | PURSUANT TO SECTION 94-441 OF THE CITY?S ZONING AND | | | LAND DEVELOPMENT REGULATIONS (ZLDRS), THE SITE SHALL BE | | | BROUGHT INTO COMPLIANCE WITH ARTICLE XIV (LANDSCAPING) | | | OF THE ZLDRS. PLANS SHALL BE SUBMITTED UNDER SEPARATE | | | PERMIT AND SHALL INCLUDE, BUT NOT BE LIMITED TO, THE | | | FOLLOWING: | | | | | | A. THE LOCATION OF ALL EXISTING AND PROPOSED STRUCTURE, | | | IMPROVEMENTS, ETC. | | | B. THE LOCATION OF ALL EXISTING AND PROPOSED TREES, | | | SHRUBS, GROUND COVERS, ETC. | | | C. THE LOCATION OF ALL UNTILITY AND DRAINAGE EASEMENTS, | | | OVERHEAD LINES, WATER METERS, TRANSFORMERS, CHECK | | | VALVES, CLEAN OUTS, FIRE HYDRANTS, LIGHT POLES, ETC. | | | THAT MAY IMPACT LANDSCAPING. | | | D. TABULATION TABLE INDICATING HOW THE EXISTING AND | | | PROPOSED PLANT MATERIAL COMPLIES WITH ARTICLE XIV. | | | E. SPECIES, QUANTITY, HEIGHT, SPREAD, SPACING, AND | | | ALLOCATION OF THE EXISTING AND PROPOSED PLANT MATERIAL. | | | F. STATEMENT THAT ALL LANDSCAPE AREAS WILL BE PROVIDED | | | WITH A PERMANENT AUTOMATIC IRRIGATION SYSTEM. PLEASE | | | NOTE THAT ANY NEW IRRIGATION SHALL BE DONE UNDER A | | | SEPARATE PERMIT. | | | | | | SUBMISSION OF THE LANDSCAPE PERMIT SHALL ALSO INCLUDE A | | | CERTIFIED COST ESTIMATE. | | | | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1448 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2013-06-26 |
|
|
Cont ID |
|
| Sent By |
eschenid |
Date |
2013-06-26 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2013-06-10 |
Time |
11:03 |
Sent To |
ENG |
|
| Notes |
| 2013-06-26 13:43:49 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 06.26.2013 | | | PERMIT NO.: 13051110 | | | ADDRESS: 1220 ORTEGA ROAD | | | CONTRACTOR/CONTACT: WILBUR HOBGOOD | | | TELEPHONE NO.: 561.691.9686 | | | SCOPE OF REVIEW: PARKING LOT AND SITE WORK AS PART OF | | | NEW ADDITION. | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. TWO (2) COPIES OF A CURRENT AND ACCURATE SURVEY | | | SHALL BE PROVIDED. | | | | | | 2. ACCORDING TO THE PERMIT APPLICATIONS SUBMITTED, THE | | | VALUE OF THE PROPOSED CONSTRUCTION ON THE SITE EXCEEDS | | | 50 PERCENT OF THE VALUE OF THE STRUCTURE. THEREFORE, | | | PURSUANT TO SECTION 94-441 OF THE CITY?S ZONING AND | | | LAND DEVELOPMENT REGULATIONS (ZLDRS), THE SITE SHALL BE | | | BROUGHT INTO COMPLIANCE WITH ARTICLE XIV (LANDSCAPING) | | | OF THE ZLDRS. PLANS SHALL BE SUBMITTED UNDER SEPARATE | | | PERMIT AND SHALL INCLUDE, BUT NOT BE LIMITED TO, THE | | | FOLLOWING: | | | | | | A. THE LOCATION OF ALL EXISTING AND PROPOSED STRUCTURE, | | | IMPROVEMENTS, ETC. | | | B. THE LOCATION OF ALL EXISTING AND PROPOSED TREES, | | | SHRUBS, GROUND COVERS, ETC. | | | C. THE LOCATION OF ALL UNTILITY AND DRAINAGE EASEMENTS, | | | OVERHEAD LINES, WATER METERS, TRANSFORMERS, CHECK | | | VALVES, CLEAN OUTS, FIRE HYDRANTS, LIGHT POLES, ETC. | | | THAT MAY IMPACT LANDSCAPING. | | | D. TABULATION TABLE INDICATING HOW THE EXISTING AND | | | PROPOSED PLANT MATERIAL COMPLIES WITH ARTICLE XIV. | | | E. SPECIES, QUANTITY, HEIGHT, SPREAD, SPACING, AND | | | ALLOCATION OF THE EXISTING AND PROPOSED PLANT MATERIAL. | | | F. STATEMENT THAT ALL LANDSCAPE AREAS WILL BE PROVIDED | | | WITH A PERMANENT AUTOMATIC IRRIGATION SYSTEM. PLEASE | | | NOTE THAT ANY NEW IRRIGATION SHALL BE DONE UNDER A | | | SEPARATE PERMIT. | | | | | | SUBMISSION OF THE LANDSCAPE PERMIT SHALL ALSO INCLUDE A | | | CERTIFIED COST ESTIMATE. | | | | | | 3. TERMINAL LANDSCAPE ISLANDS LOCATED AT THE END OF A | | | PARKING ROW SHALL BE A MINIMUM OF FIVE (5) FEET IN | | | WIDTH AS MEASURED FROM THE INSIDES OF THE CURB. | | | | | | 4. THE WALKWAY ADJACENT TO THE ACCESSIBLE PARKING SPACE | | | IS PROPOSED TO HAVE A HANDRAIL; I BELIEVE THIS WALKWAY | | | IS REQUIRED TO BE UNOBSTRUCTED ALONG THE ENTIRE LENGTH | | | OF THE PARKING STALL. | | | | | | 5. PLEASE PROVIDE A SITE PLAN THAT CONTAINS A DATA | | | TABLE WHICH INCLUDES THE FOLLOWING: | | | | | | A. EXISTING/PROPOSED LAND USE AND ZONING | | | B. TOTAL ACRES OF THE PROJECT | | | C. TOTAL GROSS BUILDING SQUARE FOOTAGE | | | D. PERCENTAGE OF OPEN SPACE, LANDSCAPING, BUILDING | | | COVERAGE & IMPERMEABLE SURFACE | | | E. ACRES AND PERCENT OF WATER BODIES | | | F. PARKING COMPUTATIONS (PARKING REQUIRED, PROVIDED, | | | ETC.) | | | G. FLOOR AREA RATIO | | | | | | 6. BASED UPON PREVIOUS DISCUSSIONS REGARDING THIS | | | PROJECT, IT WAS INDICATED THAT THE ASPHALT BETWEEN THE | | | BUILDING AND THE SOUTH PROPERTY LINE WAS TO BE REMOVED | | | AND LANDSCAPING WAS GOING TO BE INSTALLED. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1448 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.WPB.ORG | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |