Plan Review Details - Permit 13051017
Plan Review Stops For Permit 13051017
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-06-22 Cont ID  
Sent By rbrown Date 2016-06-22 Time 17:39 Rev Time 0.00
Received By rbrown Date 2016-06-22 Time 17:38 Sent To  
Notes
2016-06-22 17:40:32THE CONCLUSION OF MY CONVERSATIONS WITH FEMA'S JASON
 HUNTER AND JANICE MITCHELL IS THAT, DUE TO THE SPECIFIC
 CIRCUMSTANCES OF THE CASE AND THE IMPRACTICALITY OF
 PROVIDING USABLE FLOOD VENTS, FLOOD VENTS ARE NOT
 REQUIRED.
  
 TELEPHONE: (561) 805 6652 ROBERT BROWN
 E-MAIL: [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-07-24 Cont ID  
Sent By rmcdouga Date 2013-07-24 Time 08:04 Rev Time 0.00
Received By rmcdouga Date 2013-07-23 Time 08:14 Sent To  
Notes
2013-07-23 16:54:09REVISION IS REQUIRED
  
 THE ELEVATION CERTIFICATE THAT WAS SUBMITTED INDICATES
 THAT THE FLOOR OF THE GARAGE, AS WELL AS, SOME OF THE
 EQUIPMENT SERVICING THE BUILDING IS BELOW THE REQUIRED
 FLOOD ELEVATION OF 7.5' BFE WHICH INCLUDES THE 6"
 FREEBOARD REQUIRED BY CITY ORDINANCE. ALL EQUIPMENT IS
 REQUIRED TO BE RAISED TO OR ABOVE 7.5' BFE AND THE
 GARAGE IS REQUIRED TO COMPLY BY RAISING THE FINISH
 FLOOR OR INSTALLING FLOOD VENTS PER FBC R322.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-07-03 Cont ID  
Sent By rmcdouga Date 2013-07-03 Time 09:48 Rev Time 0.00
Received By rmcdouga Date 2013-07-03 Time 06:30 Sent To  
Notes
2013-07-03 09:48:192010 FBC
  
 DENIED BY BUILDING
  
 1) THIS PRE-FIRM STRUCTURE IS LOCATED IN AN A5 FLOOD
 ZONE. THE VALUE OF THE WORK IS $1,000,000.00 WHICH IS
 MORE THAN 50% OF THE IMPROVEMENT VALUE OF THE STRUCTURE
 LISTED ON THE PBC PROPERTY APPRAISER'S WEB SITE. THIS
 IS CONSIDERED A SUBSTANTIAL IMPROVEMENT AND THE
 EXISTING STRUCTURE IS REQUIRED TO HAVE IT'S LOWEST
 FLOOR ELEVATED TO OR ABOVE THE BFE. THE BFE FOR THIS
 LOCATION IS 7 FEET PLUS THE 6 INCH FREE BOARD PER FEMA
 FLOOD INSURANCE RATE MAPS AND CITY OF WPB FLOOD
 ORDINANCE. PLEASE SUBMIT AN ELEVATION CERTIFICATE
 SHOWING THAT THE EXISTING LOWEST FLOOR ELEVATIONS ARE
 AT OR ABOVE 7' 6" BFE OR SUBMIT A FLOOR PLAN SHOWING
 PROPOSED FIRST FLOOR ELEVATIONS WITH DETAILS OF HOW THE
 FLOORS WILL BE ELEVATED. CITY AMENDMENTS 107.2.1 AND
 FBC R322.
  
 2) THE OCCUPANCY TYPE SPECIFIED ON SHEET CVR IS
 INCORRECT. THIS IS A SINGLE FAMILY RESIDENCE THE
 CORRECT OCCUPANCY TYPE IS R3. FBC SECTION 310
  
 3) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE NEW
 EXTERIOR DOOR THAT IS TO BE REPLACED AS REQUIRED BY DCA
 RULE 9N-3.
  
 4) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR
 THE PROJECT. CITY AMENDMENTS 107.3.4
  
 5) THE DOOR FROM THE GARAGE TO THE LIVING SPACE IS
 REQUIRED TO COMPLY WITH FBC R302.5.1.
  
 6) THE DWELLING/GARAGE FIRE SEPARATION SHALL COMPLY
 WITH FBC R302.6.
  
 IN ORDER TO SPEED THE REVIEW TIME, PLEASE SUBMIT A
 RESPONSE LETTER INDICATING HOW THE REVIEW COMMENTS HAVE
 BEEN ADDRESSED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2013-07-03 Cont ID  
Sent By rmcdouga Date 2013-07-03 Time 10:38 Rev Time 0.00
Received By rmcdouga Date 2013-07-03 Time 10:38 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2013-07-02 Cont ID  
Sent By fmittner Date 2013-07-02 Time 11:52 Rev Time 0.00
Received By fmittner Date 2013-07-02 Time 11:52 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2013-05-30 Cont ID  
Sent By fmittner Date 2013-05-30 Time 09:18 Rev Time 0.00
Received By fmittner Date 2013-05-30 Time 09:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-07-24 Cont ID  
Sent By rmcdouga Date 2013-07-24 Time 08:04 Rev Time 0.00
Received By rmcdouga Date 2013-07-10 Time 14:58 Sent To  
Notes
2013-07-10 14:58:50R20

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-07-03 Cont ID  
Sent By rmcdouga Date 2013-07-03 Time 10:38 Rev Time 0.00
Received By rmcdouga Date 2013-05-30 Time 11:29 Sent To  
Notes
2013-05-31 11:29:54SENT TO R4 SHELF FOR REVIEW. JG.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2013-07-02 Cont ID  
Sent By rmcdouga Date 2013-07-02 Time 16:54 Rev Time 0.00
Received By rmcdouga Date 2013-07-02 Time 16:54 Sent To  
Notes
2013-07-02 16:57:35MECHANICAL PROVISO
  
 1) REVISED PLANS SHOWING THE LOCATION, DUCT SIZE, GRILL
 SIZE AND CFMS WILL BE REQUIRED FOR ANY NEW DUCTWORK.
  
 2) THE RENOVATION IS REQUIRED TO COMPLY WITH FBC ENERGY
 CONSERVATION SECTION 101.4.1 AND TABLE 101.4.1. MINIMUM
 CODE ENVELOPE, EQUIPMENT AND LIGHTING EFFICIENCY LEVELS
 SHALL BE MET FOR COMPONENTS BEING CHANGED.

Review Stop P PLUMBING
Rev No 1 Status P Date 2013-07-03 Cont ID  
Sent By rmcdouga Date 2013-07-03 Time 09:26 Rev Time 0.00
Received By rmcdouga Date 2013-07-03 Time 06:30 Sent To  
Notes
2013-07-03 09:27:10RED LINED PLANS

Review Stop Z ZONING
Rev No 2 Status P Date 2013-07-02 Cont ID  
Sent By fmittner Date 2013-07-02 Time 11:52 Rev Time 0.00
Received By fmittner Date 2013-07-02 Time 11:52 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2013-05-30 Cont ID  
Sent By fmittner Date 2013-05-30 Time 09:18 Rev Time 0.00
Received By fmittner Date 2013-05-30 Time 09:18 Sent To  
Notes
***NONE***