Plan Review Details - Permit 13050746
Plan Review Stops For Permit 13050746
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-10-18 Cont ID  
Sent By JWITMER Date 2013-10-18 Time 12:38 Rev Time 0.00
Received By jwitmer Date 2013-10-18 Time 12:00 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-05-31 Cont ID  
Sent By jwitmer Date 2013-05-31 Time 13:49 Rev Time 0.00
Received By jwitmer Date 2013-05-31 Time 13:10 Sent To  
Notes
2013-05-31 13:48:57BUILDING PLAN REVIEW
 PERMIT: 13050746
 ADD: 504 CLEAR LAKE AVE
 CONT: TBD
 TEL: (561)832-0472 MARY
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: 5/31/2013
 ACTION: DENIED
 NOTE CHANGE OF OCCUPANCY FROM DAY CARE 4 TO 12
 CHILDREN.
  
 2010 WEST PALM BEACH ADMINISTRATIVE CODE 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS. CONSTRUCTION
 DOCUMENTS SHALL BE DIMENSIONED AND DRAWN UPON SUITABLE
 MATERIAL. ELECTRONIC MEDIA DOCUMENTS SHALL BE SUBMITTED
 WHEN APPROVED BY THE BUILDING OFFICIAL. CONSTRUCTION
 DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE
 THE LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED
 AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL.
  
 1) PLEASE PROVIDE ADDITIONAL INFORMATION, IS THIS
 DAYCARE GOING TO OCCUPY THE WHOLE BUILDING OR IS PART
 OF THIS BUILDING STILL GOING TO REMAIN A R-3 RESIDENCE
 AND BE CONSIDERED A MIXED USE BUILDING? HOW LONG WILL
 THE CHILDREN BE THERE DAILY? 107.2.1.3 ADDITIONAL
 INFORMATION IS REQUIRED. THIS PLAN REVIEW WILL CONSIDER
 THIS USAGE AS A MIXED USE OCCUPANCY. 2010 EXISTING
 BUILDING CODE 901.3.1 PARTIAL CHANGE OF OCCUPANCY
 CLASSIFICATION. WHERE A PORTION OF AN EXISTING BUILDING
 IS CHANGED TO A NEW OCCUPANCY CLASSIFICATION, SECTION
 912 SHALL APPLY.
  
 2) THE SUBMITTED PLANS WILL NEED TO DETERMINE IF THE
 DESIGN IS TO BE 912.1.1.1 CHANGE OF OCCUPANCY
 CLASSIFICATION WITHOUT SEPARATION OR 912.1.1.2 CHANGE
 OF OCCUPANCY CLASSIFICATION WITH SEPARATION.
  
 3) 2010 EXISTING BUILDING CODE 912.2.2 FIRE ALARM AND
 DETECTION SYSTEM. WHERE A CHANGE IN OCCUPANCY
 CLASSIFICATION OCCURS THAT REQUIRES A FIRE ALARM AND
 DETECTION SYSTEM TO BE PROVIDED BASED ON THE NEW
 OCCUPANCY IN ACCORDANCE WITH CHAPTER 9 OF THE FLORIDA
 BUILDING CODE, BUILDING, SUCH SYSTEM SHALL BE PROVIDED
 THROUGHOUT THE AREA WHERE THE CHANGE OF OCCUPANCY
 OCCURS. EXISTING ALARM NOTIFICATION APPLIANCES SHALL BE
 AUTOMATICALLY ACTIVATED THROUGHOUT THE BUILDING. WHERE
 THE BUILDING IS NOT EQUIPPED WITH A FIRE ALARM SYSTEM,
 ALARM NOTIFICATION APPLIANCES SHALL BE PROVIDED
 THROUGHOUT THE AREA WHERE THE CHANGE OF OCCUPANCY
 OCCURS AND SHALL BE AUTOMATICALLY ACTIVATED.
 2010 FBC-B 436.7.2 DETECTION. A SMOKE DETECTION SYSTEM
 SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 72, WITH
 PLACEMENT OF DETECTORS IN EACH STORY IN FRONT OF DOORS
 TO THE STAIRWAYS AND IN THE CORRIDORS OF ALL FLOORS
 OCCUPIED BY THE DAY CARE OCCUPANCY. DETECTORS ALSO
 SHALL BE INSTALLED IN LOUNGES, RECREATION AREAS AND
 SLEEPING ROOMS IN THE DAY CARE OCCUPANCY.
 436.10.5 SMOKE DETECTION SYSTEMS.
 436.10.5.1
 SINGLE-STATION SMOKE ALARMS INSTALLED IN ACCORDANCE
 WITH THE HOUSEHOLD FIRE WARNING EQUIPMENT REQUIREMENTS
 OF CHAPTER 2 OF NFPA 72 SHALL BE INSTALLED WITHIN DAY
 CARE HOMES.
 EXCEPTION: SYSTEM SMOKE DETECTORS INSTALLED IN
 ACCORDANCE WITH NFPA 72 AND ARRANGED TO FUNCTION IN THE
 SAME MANNER SHALL BE PERMITTED.
 436.10.5.2
 WHERE THE DAY CARE HOME IS LOCATED WITHIN A BUILDING OF
 ANOTHER OCCUPANCY, ANY CORRIDORS SERVING THE DAY CARE
 HOME SHALL BE PROVIDED WITH A COMPLETE SMOKE DETECTION
 SYSTEM INSTALLED IN ACCORDANCE WITH NFPA 72.
 436.10.5.3
 SINGLE-STATION SMOKE ALARMS SHALL BE POWERED BY THE
 BUILDING ELECTRICAL SYSTEM.
 436.10.5.4
 SINGLE-STATION SMOKE ALARMS SHALL BE PROVIDED IN ALL
 ROOMS USED FOR SLEEPING.
 436.10.5.5
 WHERE TWO OR MORE SMOKE ALARMS ARE REQUIRED WITHIN A
 LIVING UNIT, SUITE OF ROOMS, OR SIMILAR AREA, THEY
 SHALL BE ARRANGED SO THAT OPERATION OF ANY SMOKE ALARM
 SHALL CAUSE ALL SMOKE ALARMS WITHIN THE LIVING UNIT,
 SUITE OF ROOMS OR SIMILAR AREA TO SOUND.
 436.10.5.5.1
 THE ALARMS SHALL SOUND ONLY WITHIN AN INDIVIDUAL LIVING
 UNIT, SUITE OF ROOMS OR SIMILAR AREA AND SHALL NOT
 ACTUATE THE BUILDING FIRE ALARM SYSTEM. REMOTE
 ANNUNCIATION SHALL BE PERMITTED.
  
  
 4) PLEASE PROVIDE A LIFE SAFETY PLAN SHOWING EGRESS IN
 TO THE STRUCTURE, DOORS WITHIN THE STRUCTURE, WINDOW,
 AND OPENING SIZE FOR EACH ROOM THAT WILL HOUSE
 CHILDREN.
 2010 FBC-B 1029.4.1. IN GROUP D OCCUPANCIES SHALL HAVE
 NOT LESS THAN ONE OUTSIDE WINDOW FOR EMERGENCY RESCUE
 THAT COMPLIES WITH THE FOLLOWING:
 1. SUCH WINDOWS SHALL BE OPENABLE FROM THE INSIDE
 WITHOUT THE USE OF TOOLS AND SHALL PROVIDE A CLEAR
 OPENING OF NOT LESS THAN 20 INCHES (508 MM) IN WIDTH,
 24 INCHES (610 MM) IN HEIGHT, AND 5.7 SQUARE FEET (0.53
 M2) IN AREA.
 2. THE BOTTOM OF THE OPENING SHALL BE NOT MORE THAN 44
 INCHES (1118 MM) ABOVE THE FLOOR, AND ANY LATCHING
 DEVICE SHALL BE CAPABLE OF BEING OPERATED FROM NOT MORE
 THAN 54 INCHES (1372 MM) ABOVE THE FINISHED FLOOR.
  
 5) 2010 FBC-B 436.6.1 THE FOLLOWING ROOMS OR SPACES
 SHALL BE SEPARATED FROM THE REMAINDER OF THE BUILDING
 BY FIRE BARRIERS HAVING A FIRE RESISTANCE RATING OF NOT
 LESS THAN 1-HOUR OR SHALL BE PROTECTED BY AN APPROVED
 AUTOMATIC EXTINGUISHING SYSTEM.
 1. BOILER AND FURNACE ROOMS.
 EXCEPTION: ROOMS ENCLOSING ONLY AIR-HANDLING EQUIPMENT.
 2. ROOMS OR SPACES USED FOR THE STORAGE OF COMBUSTIBLE
 SUPPLIES IN QUANTITIES DEEMED HAZARDOUS BY THE BUILDING
 OFFICIAL.
 3. ROOMS OR SPACES USED FOR THE STORAGE OF HAZARDOUS
 MATERIALS OR FLAMMABLE OR COMBUSTIBLE LIQUIDS IN
 QUANTITIES DEEMED HAZARDOUS BY RECOGNIZED STANDARDS.
 4. JANITOR CLOSETS.
 EXCEPTION: DOORS TO JANITOR CLOSETS SHALL BE PERMITTED
 TO HAVE VENTILATING LOUVERS WHERE THE SPACE IS
 PROTECTED BY AUTOMATIC SPRINKLERS.
  
 6) 2010 FBC-B 436.6.2 THE FOLLOWING ROOMS OR SPACES
 SHALL BE SEPARATED FROM THE REMAINDER OF THE BUILDING
 BY FIRE BARRIERS HAVING A FIRE RESISTANCE RATING OF NOT
 LESS THAN 1 HOUR AND SHALL BE PROTECTED BY AN APPROVED
 AUTOMATIC FIRE-EXTINGUISHING SYSTEM.
 1. LAUNDRIES.
 2. MAINTENANCE SHOPS, INCLUDING WOODWORKING AND
 PAINTING AREAS.
 3. ROOMS OR SPACES USED FOR PROCESSING OR USE OF
 COMBUSTIBLE SUPPLIES DEEMED HAZARDOUS BY THE BUILDING
 OFFICIAL.
 4. ROOMS OR SPACES USED FOR PROCESSING OR USE OF
 HAZARDOUS MATERIALS OR FLAMMABLE OR COMBUSTIBLE LIQUIDS
 IN QUANTITIES DEEMED HAZARDOUS BY RECOGNIZED STANDARDS.
  
 7) 2010 FBC-B 436.10.4 OCCUPANCIES THAT INCLUDE
 PART-DAY PRESCHOOLS, KINDERGARTENS AND OTHER SCHOOLS
 WHOSE PURPOSE IS PRIMARILY EDUCATIONAL EVEN THOUGH THE
 CHILDREN ARE OF PRESCHOOL AGE SHALL COMPLY WITH THE
 PROVISIONS FOR GROUP E OCCUPANCY. IS THERE ANY TEACHING
 OF CHILDREN THAT WILL MAKE TTHE REQUIREMENTS FOR
 EDUCATION APPLY?
  
  
 8) 2010 FL ACCESSIBILITY CODE
 202.4.1 DISPROPORTIONATE COST.
 ALTERATIONS MADE TO PROVIDE AN ACCESSIBLE PATH OF
 TRAVEL TO THE ALTERED AREA WILL BE DEEMED
 DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN THE
 COST EXCEEDS 20% OF THE COST OF THE ALTERATION TO THE
 PRIMARY FUNCTION AREA. COSTS THAT MAY BE COUNTED AS
 EXPENDITURES REQUIRED TO PROVIDE AN ACCESSIBLE PATH OF
 TRAVEL MAY INCLUDE: (I) COSTS ASSOCIATED WITH PROVIDING
 AN ACCESSIBLE ENTRANCE AND AN ACCESSIBLE ROUTE TO THE
 ALTERED AREA; (II) COSTS ASSOCIATED WITH MAKING
 RESTROOMS ACCESSIBLE, SUCH AS INSTALLING GRAB BARS,
 ENLARGING TOILET STALLS, INSULATING PIPES, OR
 INSTALLING ACCESSIBLE FAUCET CONTROLS; (III) COSTS
 ASSOCIATED WITH PROVIDING ACCESSIBLE TELEPHONES, SUCH
 AS RELOCATING THE TELEPHONE TO AN ACCESSIBLE HEIGHT,
 INSTALLING AMPLIFICATION DEVICES, OR INSTALLING A TEXT
 TELEPHONE (TTY); (IV) COSTS ASSOCIATED WITH RELOCATING
 AN INACCESSIBLE DRINKING FOUNTAIN.
  
 202.4.2 ACCESSIBLE FEATURES IN THE EVENT OF
 DISPROPORTIONALITY.
 WHEN THE COST OF ALTERATIONS NECESSARY TO MAKE THE PATH
 OF TRAVEL TO THE ALTERED AREA FULLY ACCESSIBLE IS
 DISPROPORTIONATE TO THE COST OF THE OVERALL ALTERATION,
 THE PATH OF TRAVEL SHALL BE MADE ACCESSIBLE TO THE
 EXTENT THAT IT CAN BE MADE ACCESSIBLE WITHOUT INCURRING
 DISPROPORTIONATE COSTS. IN CHOOSING WHICH ACCESSIBLE
 ELEMENTS TO PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE
 ELEMENTS THAT WILL PROVIDE THE GREATEST ACCESS, IN THE
 FOLLOWING ORDER: (I) AN ACCESSIBLE ENTRANCE; (II) AN
 ACCESSIBLE ROUTE TO THE ALTERED AREA; (III) AT LEAST
 ONE ACCESSIBLE RESTROOM FOR EACH SEX OR A SINGLE UNISEX
 RESTROOM; (IV) ACCESSIBLE TELEPHONES; (V) ACCESSIBLE
 DRINKING FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL
 ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND
 ALARMS.
  
 A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2013-10-22 Cont ID  
Sent By DHARVEY Date 2013-10-22 Time 18:25 Rev Time 0.00
Received By albarran Date 2013-10-22 Time 18:25 Sent To  
Notes
2013-10-22 18:27:57FURTHER ELECTRICAL REVIEW WILL BE REQUIRED WITH THE
 SUPPLEMENTAL FIRE ALARM PERMIT IF REQUIRED BY FIRE
 REVIEW

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2013-06-05 Cont ID  
Sent By dharvey Date 2013-06-05 Time 09:25 Rev Time 0.00
Received By dharvey Date 2013-06-05 Time 09:25 Sent To  
Notes
2013-06-05 09:28:376-5-13
 PLEASE PROVIDE A COMPLETE SET OF ELECTRICAL DRAWINGS TO
 COMPLY WITH THE NATIONAL ELELCTRICAL CODE
 VB

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2013-11-12 Cont ID  
Sent By WJOLIN Date 2013-11-12 Time 14:03 Rev Time 0.00
Received By wjolin Date 2013-11-12 Time 13:54 Sent To B
Notes
2013-11-12 14:03:19504 CLEAR LAKE AVENUE
 OCCUPANCY: GROUP DAY-CARE HOME WITH 7 TO 12 CLIENTS
 PERMIT #13050746
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 NOTE: DAY-CARE OCCUPANCIES WITH MORE THAN 12 CLIENTS
 WILL REQUIRE A MONITORED MANUAL FIRE ALARM SYSTEM
  
 PROVIDE PORTABLE FIRE EXTINGUISHERS.
  
 SINGLE/MULTI-STATION SMOKE ALARMS OR SMOKE DETECTORS
 (HARD-WIRED OR BATTERY POWERED) SHALL BE INSTALLED IN
 ALL AREAS USED FOR SLEEPING.
  
 ARTWORK AND TEACHING MATERIALS ATTACHED TO THE WALLS
 SHALL NOT EXCEED 20 PERCENT OF THE INDIVIDUAL WALL
 AREA.
  
 SPECIAL PROTECTIVE COVERS FOR ALL ELECTRICAL
 RECEPTACLES SHALL BE INSTALLED IN ALL AREAS OCCUPIED BY
 CLIENTS.
  
 AN EMERGENCY PLAN TO BE DEVELOPED AND POSTED IN
 BUILDING PRIOR TO OCCUPANCY. EMERGENCY EGRESS DRILLS
 SHALL BE CONDUCTED MONTHLY.
  
 FIRE PREVENTION INSPECTIONS SHALL BE CONDUCTED MONTHLY
 BY A TRAINED SENIOR MEMBER OF THE STAFF, AFTER WHICH A
 COPY OF THE LATEST INSPECTION REPORT SHALL BE POSTED IN
 A CONSPICUOUS PLACE IN THE DAY-CARE FACILITY. IT SHALL
 BE THE DUTY OF THE STAFF TO INSPECT ALL EXITS DAILY TO
 ENSURE THAT ALL DOORS AND EXIT PATHS ARE MAINTAINED
 CLEAR OF OBSTRUCTIONS.
  
 WESLEY JOLIN
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2013-06-07 Cont ID  
Sent By wjolin Date 2013-06-07 Time 14:24 Rev Time 0.00
Received By wjolin Date 2013-06-07 Time 14:02 Sent To  
Notes
2013-06-07 14:24:20504 CLEAR LAKE AVENUE
 OCCUPANCY: GROUP DAY-CARE HOME WITH 7 TO 12 CLIENTS
 PERMIT #13050746
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 DESIGN SHALL COMPLY WITH CHAPTER 16 (NEW DAY-CARE
 OCCUPANCY) OF THE 2010 EDITION OF THE FLORIDA FIRE
 PREVENTION CODE WHICH CONTAINS THE 2009 EDITION OF BOTH
 NFPA 1 AND NFPA 101 WITH FLORIDA AMENDMENTS.
  
 PROVIDE A LIFE SAFETY PLAN SHOWING ALL EXIT DOORS,
 RESCUE WINDOWS, FIRE EXTINGUISHERS, AND LIGHTING.
 INDICATE IF THE ENTIRE HOUSE IS BEING USED FOR DAY-CARE
 OR JUST THE ONE ROOM.
  
 SINGLE/MULTI-STATION SMOKE ALARMS OR SMOKE DETECTORS
 (HARD-WIRED OR BATTERY POWERED) SHALL BE INSTALLED IN
 ALL AREAS USED FOR SLEEPING.
  
 ARTWORK AND TEACHING MATERIALS ATTACHED TO THE WALLS
 SHALL NOT EXCEED 50 PERCENT OF THE INDIVIDUAL WALL
 AREA.
  
 SPECIAL PROTECTIVE COVERS FOR ALL ELECTRICAL
 RECEPTACLES SHALL BE INSTALLED IN ALL AREAS OCCUPIED BY
 CLIENTS.
  
 AN EMERGENCY PLAN TO BE DEVELOPED AND POSTED IN
 BUILDING PRIOR TO OCCUPANCY.
 EMERGENCY EGRESS DRILLS SHALL BE CONDUCTED MONTHLY. ALL
 DRILLS SHALL BE SOUNDED ON THE FIRE ALARM SYSTEM.
  
 FIRE PREVENTION INSPECTIONS SHALL BE CONDUCTED MONTHLY
 BY A TRAINED SENIOR MEMBER OF THE STAFF, AFTER WHICH A
 COPY OF THE LATEST INSPECTION REPORT SHALL BE POSTED IN
 A CONSPICUOUS PLACE IN THE DAY-CARE FACILITY. IT SHALL
 BE THE DUTY OF THE STAFF TO INSPECT ALL EXITS DAILY TO
 ENSURE THAT ALL DOORS AND EXIT PATHS ARE MAINTAINED
 CLEAR OF OBSTRUCTIONS.
  
 ESCAPE/RESCUE WINDOWS
 (1) SUCH WINDOWS SHALL BE OPERABLE FROM THE INSIDE
 WITHOUT THE USE OF TOOLS AND SHALL PROVIDE A CLEAR
 OPENING OF NOT LESS THAN 20-INCHES IN WIDTH, 24-INCHES
 IN HEIGHT, AND 5.7 SQ.FT. IN AREA.
 (2) THE BOTTOM OF THE OPENING SHALL BE NOT MORE THAN
 44-INCHES ABOVE THE FLOOR.
 (3) THE CLEAR OPENING SHALL ALLOW A RECTANGULAR SOLID,
 WITH A WIDTH AND HEIGHT THAT PROVIDES NOT LESS THAN THE
 REQUIRED 5.7 SQ.FT. OPENING AND A DEPTH OF NOT LESS
 THAN 20-INCEHS TO PASS FULLY THROUGH THE OPENING.
  
 AT THIS TIME, A THOROUGH AND COMPLETE PLAN REVIEW
 CANNOT BE PERFORMED DUE TO A LACK OF PLAN INFORMATION.
  
 WESLEY JOLIN
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-11-12 Cont ID  
Sent By jwitmer Date 2013-11-12 Time 14:47 Rev Time 0.00
Received By jwitmer Date 2013-09-25 Time 07:57 Sent To  
Notes
2013-09-26 08:00:10B25

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-06-10 Cont ID  
Sent By hmoser Date 2013-06-10 Time 10:54 Rev Time 0.00
Received By hmoser Date 2013-05-22 Time 10:34 Sent To  
Notes
2013-05-24 10:37:08B--24

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2013-11-12 Cont ID  
Sent By jwitmer Date 2013-11-12 Time 14:47 Rev Time 0.00
Received By jwitmer Date 2013-11-12 Time 14:47 Sent To  
Notes
2013-11-12 14:47:41BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2013-05-31 Cont ID  
Sent By jwitmer Date 2013-05-31 Time 13:49 Rev Time 0.00
Received By jwitmer Date 2013-05-31 Time 13:49 Sent To  
Notes
2013-05-31 13:49:52BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2013-06-10 Cont ID  
Sent By hmoser Date 2013-06-10 Time 10:54 Rev Time 0.00
Received By hmoser Date 2013-06-10 Time 10:54 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2013-09-30 Cont ID  
Sent By LWAGNER Date 2013-09-30 Time 12:30 Rev Time 0.00
Received By lwagner Date 2013-09-30 Time 11:07 Sent To  
Notes
2013-09-30 12:31:24PLUMBING PERMIT, APPLICATION, AND DRAWING REQUIRED.

Review Stop P PLUMBING
Rev No 1 Status F Date 2013-06-03 Cont ID  
Sent By lwagner Date 2013-06-03 Time 10:28 Rev Time 0.00
Received By lwagner Date 2013-06-03 Time 09:49 Sent To  
Notes
2013-06-03 10:27:56FBC 2010 EXISTING BUILDING CODE
 FBC 2010 PLUMBING REVIEW #1
 DENIED:
  
 EDUCATIONAL/ DAYCARE FACILITIES REQUIRE A SERVICE SINK.
 FBC PLUMBING TABLE 403.1
  
 NOTE
 THE HEALTH DEPARTMENT MAY HAVE OTHER REQUIREMENTS:
 HTTP://WWW.PBCHD.COM/ENV/ENVIRONMENTAL.HTML
  
  
 REVIEW BY
 LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 PHONE # 805-6692
 EMAIL [email protected]
 FAX # 805-6676
  

Review Stop Z ZONING
Rev No 1 Status N Date 2013-06-03 Cont ID  
Sent By ajones Date 2013-06-03 Time 14:45 Rev Time 0.00
Received By ajones Date 2013-06-03 Time 14:45 Sent To  
Notes
***NONE***