Plan Review Details - Permit 13050574
Plan Review Stops For Permit 13050574
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2013-07-01 Cont ID  
Sent By shill Date 2013-07-01 Time 11:09 Rev Time 0.00
Received By shill Date 2013-07-01 Time 11:09 Sent To  
Notes
2013-07-15 17:14:087/15 REVIEWED COST BREAKDOWN, ROUTED TO RECORDS
  
  
2013-07-01 11:10:19COST BREAKDOWN TO BE EMAILED PRIOR TO FIRST INSPECTION
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2013-07-01 Cont ID  
Sent By shill Date 2013-07-01 Time 08:43 Rev Time 0.00
Received By shill Date 2013-07-01 Time 08:43 Sent To  
Notes
2013-07-01 08:44:34****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. FBC 109, VALUE IS TO INCLUDE ALL LABOR AND
 MATERIALS. A COPY OF THE CONTRACT HAS BEEN REQUESTED
 FROM CONTRACTOR, BUT NOT YET RECEIVED. THIS MAY BE
 SUBMITTED VIA EMAIL TO [email protected].
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2013-06-27 Cont ID  
Sent By shill Date 2013-06-27 Time 06:23 Rev Time 0.00
Received By shill Date 2013-06-27 Time 06:23 Sent To  
Notes
2013-06-27 06:24:07****PROVISO****
 ****REVISION REQUIRED****
 ****ISSUED AT CONTRACTOR'S RISK****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 SUBMIT SPEC SHEETS FOR ACOUSTICAL INSULATION AS A
 REVISION TO SHOW COMPLIANCE WITH THE FOLLOWING:
  
 1. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.
  
 2. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492.
  
 3. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 SEE 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM
 E 84 OR UL 723.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2013-06-14 Cont ID  
Sent By jwitmer Date 2013-06-14 Time 13:15 Rev Time 0.00
Received By jwitmer Date 2013-06-14 Time 12:31 Sent To  
Notes
2013-06-14 12:33:52BUILDING PLAN REVIEW
 PERMIT: 13050574
 ADD: 622 N FLAGLER DR # 901
 CONT: JOSEPH EDWARD KELLY III
 TEL: (954)383-5151
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: 6/14/13
 ACTION: DENIED
 SAME COMMENTS FROM FIRST REVIEW!!!!
  
 INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 1) THE CONTRACTOR JOSEPH EDWARD KELLY III IS LICENSED
 AS A CERTIFIED RESIDENTIAL CONTRACTOR, PLEASE REVIEW
 LICENSING DEFINITION FL S 489.105(C) "RESIDENTIAL
 CONTRACTOR" MEANS A CONTRACTOR WHOSE SERVICES ARE
 LIMITED TO CONSTRUCTION, REMODELING, REPAIR, OR
 IMPROVEMENT OF ONE-FAMILY, TWO-FAMILY, OR THREE-FAMILY
 RESIDENCES NOT EXCEEDING TWO HABITABLE STORIES ABOVE NO
 MORE THAN ONE UNINHABITABLE STORY AND ACCESSORY USE
 STRUCTURES IN CONNECTION THEREWITH. THIS IS A HIGH-RISE
 BEYOND THE SCOPE OF YOUR LICENSE, " REMODELING, REPAIR,
 OR IMPROVEMENT OF ONE-FAMILY, TWO-FAMILY, OR
 THREE-FAMILY RESIDENCES"...
  
 2) THE CONBTRACTOR INDICATES ON THE PERMIT APPLICATION
 UNDER SCOPE OF WORK INLAY WORK OF MARBLE FLOORING BUT
 THERE IS NO SUBMITTALS FOR CODE COMPLIANCE FOR THE
 FOLLOWING CODE REQUIREMENTS;
 FBC-B 2010 2010 FBC-B 603.2
 2A) FLOOR INSULATION PLACED BETWEEN TWO LAYERS OF
 NONCOMBUSTIBLE MATERIALS WITHOUT AN INTERVENING
 AIRSPACE SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX
 OF NOT MORE THAN 100.
  
 2B) 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 3) SHEET 101 INDICATES IN MANY ROOMS NEW CEILING AS
 REQUIRED FOR NEW CEILING DESIGN, THE OTHER NOTE ABOUT
 CEILING DESIGN IS VERIFY WITH ARCHITECT IN FIELD.
 PLEASE PROVIDE THE FRAMING FOR ALL DROPED CEILINGS,
 SOFFITS, ETC.. PROVIDE FRAMING TYPE OF MATERIALS, SIZE
 OF FRAMING, GAUGE OF FRAMING AND SPACING OF FRAMING AND
 IF STIFF BACK WILL BE REQUIRED. PLEASE PROVIDE THE TYPE
 OF FASTENERS TO THE DECK ABOVE, AS WELL AS THE TYPE OF
 FINISH AND THICKNESS TO BE APPLIED AND AT WHAT THE
 FINISH CEILING HEIGHT, OR SOFFIT HEIGHT WILL BE.
 2010 FBC-B TABLE 2506.2STEEL STUDS NON-BEARING ASTM C
 645 & TABLE 2508.1 STEEL FRAMING FOR GYPSUM BOARD.
  
 4) SHEET A101 THE NEW DOOR THAT LEADS INTO THE MASTER
 BATHROOM IS LABELED A 2'-8" DOOR, THIS WILL PROVIDE A
 30 INCH CLEAR OPENING. PLEASE BE AWARE THIS CONDOMINIUM
 IS CONSIDERED UNDER THE FAIR HOUSING REQUIREMENTS, FOR
 USABLE DOORS. SEE HINGED DOORS SINGLE LEAF.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-05-20 Cont ID  
Sent By jwitmer Date 2013-05-20 Time 13:16 Rev Time 0.00
Received By jwitmer Date 2013-05-20 Time 12:30 Sent To  
Notes
2013-05-20 13:00:56BUILDING PLAN REVIEW
 PERMIT: 13050574
 ADD: 622 N FLAGLER DR # 901
 CONT: JOSEPH EDWARD KELLY III
 TEL: (954)383-5151
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: 5/20/2013
 ACTION: DENIED
  
 1) THE CONTRACTOR JOSEPH EDWARD KELLY III IS LICENSED
 AS A CERTIFIED RESIDENTIAL CONTRACTOR, PLEASE REVIEW
 LICENSING DEFINITION FL S 489.105(C) "RESIDENTIAL
 CONTRACTOR" MEANS A CONTRACTOR WHOSE SERVICES ARE
 LIMITED TO CONSTRUCTION, REMODELING, REPAIR, OR
 IMPROVEMENT OF ONE-FAMILY, TWO-FAMILY, OR THREE-FAMILY
 RESIDENCES NOT EXCEEDING TWO HABITABLE STORIES ABOVE NO
 MORE THAN ONE UNINHABITABLE STORY AND ACCESSORY USE
 STRUCTURES IN CONNECTION THEREWITH. THIS IS A HIGH-RISE
 BEYOND THE SCOPE OF YOUR LICENSE, " REMODELING, REPAIR,
 OR IMPROVEMENT OF ONE-FAMILY, TWO-FAMILY, OR
 THREE-FAMILY RESIDENCES"...
  
 2) THE CONBTRACTOR INDICATES UNDER SCOPE OF WORK INLAY
 WORK OF MARBLE FLOORING BUT THERE IS NO SUBMITTALS FOR
 CODE COMPLIANCE FOR THE FOLLOWING CODE REQUIREMENTS;
 FBC-B 2010 2010 FBC-B 603.2
 2A) FLOOR INSULATION PLACED BETWEEN TWO LAYERS OF
 NONCOMBUSTIBLE MATERIALS WITHOUT AN INTERVENING
 AIRSPACE SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX
 OF NOT MORE THAN 100.
  
 2B) 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 3) SHEET 101 INDICATES IN MANY ROOMS NEW CEILING AS
 REQUIRED FOR NEW CEILING DESIGN, THE OTHER NOTE ABOUT
 CEILING DESIGN IS VERIFY WITH ARCHITECT IN FIELD.
 PLEASE PROVIDE THE FRAMING FOR ALL DROPED CEILINGS,
 SOFFITS, ETC.. PROVIDE FRAMING TYPE OF MATERIALS, SIZE
 OF FRAMING, GAUGE OF FRAMING AND SPACING OF FRAMING AND
 IF STIFF BACK WILL BE REQUIRED. PLEASE PROVIDE THE TYPE
 OF FASTENERS TO THE DECK ABOVE, AS WELL AS THE TYPE OF
 FINISH AND THICKNESS TO BE APPLIED AND AT WHAT THE
 FINISH CEILING HEIGHT, OR SOFFIT HEIGHT WILL BE.
 2010 FBC-B TABLE 2506.2STEEL STUDS NON-BEARING ASTM C
 645 & TABLE 2508.1 STEEL FRAMING FOR GYPSUM BOARD.
  
 4) SHEET A101 THE NEW DOOR THAT LEADS INTO THE MASTER
 BATHROOM IS LABELED A 2'-8" DOOR, THIS WILL PROVIDE A
 30 INCH CLEAR OPENING. PLEASE BE AWARE THIS CONDOMINIUM
 IS CONSIDERED UNDER THE FAIR HOUSING REQUIREMENTS, FOR
 USABLE DOORS. SEE HINGED DOORS SINGLE LEAF.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2013-06-21 Cont ID  
Sent By shill Date 2013-06-27 Time 06:35 Rev Time 0.00
Received By dharvey Date 2013-06-21 Time 09:07 Sent To  
Notes
2013-06-21 10:19:54BY RL

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2013-06-11 Cont ID  
Sent By dharvey Date 2013-06-11 Time 13:51 Rev Time 0.00
Received By dharvey Date 2013-06-11 Time 13:51 Sent To FIRE
Notes
2013-06-11 13:51:586-11-13
 APPROVED WITH EXCEPTION. SEE NOTES ON DRAWINGS
 VB

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2013-05-23 Cont ID  
Sent By dharvey Date 2013-05-23 Time 09:47 Rev Time 0.00
Received By dharvey Date 2013-05-23 Time 09:47 Sent To  
Notes
2013-05-23 09:51:275-23-13
 1. PROVIDE PANEL SCHEDULE PER NEC 408.4
 2. ALL NEW AND RELOCATED CIRCUITS TO HAVE AFCI
 PROTECTION PER NEC 211.12B
 3. ALL NEW, RELOCATED OR REPLACED RECEPTS TO BE TAMPER
 RESISTANT PER NEC 406.11
 4. ADD SMOKE ALARMS PER RESIDENTIAL CODE SECTIONS 314
 AND 315
 5. ALL ELECTRICAL DEMO CONDUIT AND CONDUCTORS MUST BE
 REMOVED BACK TO ORIGINATION POINT
 VB

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2013-06-22 Cont ID  
Sent By wjolin Date 2013-06-22 Time 15:46 Rev Time 0.00
Received By wjolin Date 2013-06-22 Time 15:45 Sent To B
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2013-05-18 Cont ID  
Sent By wjolin Date 2013-05-18 Time 18:08 Rev Time 0.00
Received By wjolin Date 2013-05-18 Time 17:58 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2013-06-27 Cont ID  
Sent By jwitmer Date 2013-06-27 Time 06:35 Rev Time 0.00
Received By shill Date 2013-06-20 Time 17:15 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-06-14 Cont ID  
Sent By jwitmer Date 2013-06-14 Time 13:32 Rev Time 0.00
Received By jwitmer Date 2013-06-05 Time 11:00 Sent To  
Notes
2013-06-08 11:01:14*EXPEDITED*
 GAVE TO VINNY

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-05-24 Cont ID  
Sent By lmartine Date 2013-05-24 Time 12:18 Rev Time 0.00
Received By lmartine Date 2013-05-16 Time 15:04 Sent To  
Notes
2013-05-17 15:08:33EXPEDITED
 B--5

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2013-06-27 Cont ID  
Sent By shill Date 2013-06-27 Time 06:34 Rev Time 0.00
Received By shill Date 2013-06-27 Time 06:34 Sent To  
Notes
2013-06-27 06:35:16MECHANICAL CONTRACTOR TO SUBMIT PLANS AND PERMIT
 APPLICATION
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2013-05-24 Cont ID  
Sent By lmartine Date 2013-05-24 Time 12:18 Rev Time 0.00
Received By lmartine Date 2013-05-24 Time 12:17 Sent To  
Notes
2013-05-24 12:18:46SEPARATE PLANS AND PERMIT WILL BE REQUIRED