Plan Review Details - Permit 13050571
Plan Review Stops For Permit 13050571
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2013-11-12 Cont ID  
Sent By rmcdouga Date 2013-11-12 Time 10:39 Rev Time 0.00
Received By rmcdouga Date 2013-11-12 Time 10:39 Sent To Z
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-10-22 Cont ID  
Sent By rmcdouga Date 2013-10-22 Time 15:52 Rev Time 0.00
Received By rmcdouga Date 2013-10-22 Time 12:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-06-27 Cont ID  
Sent By rmcdouga Date 2013-06-27 Time 16:57 Rev Time 0.00
Received By rmcdouga Date 2013-06-26 Time 14:54 Sent To  
Notes
2013-06-27 11:36:592010 FBC
  
 DENIED BY BUILDING
  
 1) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE NEW
 WINDOWS AND DOORS AS REQUIRED BY DCA RULE 9N-3.
  
 2) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. CITY
 AMENDMENTS 107.3.4.1
  
 3) PROVIDE DETAILS THAT SHOW COMPLIANCE WITH FBC R312
 FOR THE STAIR GUARDS (RAILS).
  
 4) PROVIDE ADDITIONAL STRUCTURAL DETAILS FOR THE
 STAIRS. SPECIFY INTERMEDIATE SUPPORT, NUMBER OF
 STRINGERS, LANDING DIMENSIONS, ETC.
  
 5) SHOW COMPLIANCE WITH FBCR 311.7.5 FOR STAIRWAY
 LANDINGS.
  
 6) THE PLANS SPECIFY CDX PLYWOOD FOR THE RISERS ON THE
 EXTERIOR STAIRS. THIS DOES NOT COMPLY WITH R317 FOR
 PROTECTION OF WOOD AND WOOD PRODUCTS FROM DECAY.
  
 7) THE DESIGN INFORMATION ON SHEET A1 IS NOT CORRECT.
 THE WIND SPEED IS 170 MPH NOT 167MPH. THE EXPOSURE
 CATEGORY IS C NOT B. THE CONSTRUCTION TYPE IS VB NOT V.
 FBC R301
  
 8) SHOW THE CONTINUOUS LOAD PATH FROM THE LOAD BEARING
 4 X 4 POSTS ON THE 2ND FLOOR THROUGH THE FIRST FLOOR TO
 THE FOUNDATION. FBC R 601.2
  
 9) SHOW COMPLIANCE WITH FBC R302.3 FOR THE REQUIRED ONE
 HOUR FIRE-RESISTANCE RATING FLOOR/CEILING ASSEMBLY THAT
 SEPARATES THE TWO DWELLING UNITS.
  
 10) SUBMIT ENERGY CALCULATIONS FOR THE TWO DWELLING
 UNITS THAT ARE BEING CHANGED FROM NONCONDITIONED SPACE
 TO CONDITIONED SPACE. FBC ENERGY SECTION 101.4.5
  
 11) SHOW COMPLIANCE WITH FBC ENERGY SECTION 402.2.12
 FOR INSULATION IN THE FLOOR/CEILING ASSEMBLY BETWEEN
 THE TWO UNITS.
  
 12) PROVIDE A DETAIL FOR THE WATER HEATER THAT IS
 LOCATED IN THE HVAC PLENUM. SHOW THE WATER HEATER PAN
 AND PAN DRAIN TERMINATING TO THE EXTERIOR OF THE
 BUILDING. FBCR P2801
  
 13) IT APPEARS THAT THE HVAC DUCT WORK FOR THE FIRST
 FLOOR WILL NEED TO BE INSTALLED UNDER THE FLOOR/CEILING
 ASSEMBLY IN A SOFFIT, BASED ON THE PLANS THAT WERE
 SUBMITTED. PLEASE REVIEW THE DESIGN AND CLARIFY HOW THE
 DUCTS WILL BE INSTALLED BELOW THE ONE HOUR FIRE RATED
 FLOOR/CEILING ASSEMBLY. CITY AMENDMENTS 107.2.1
  
 PLEASE PROVIDE A RESPONSE LETTER INDICATING HOW EACH OF
 THE REVIEW COMMENTS WAS ADDRESSED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2013-12-11 Cont ID  
Sent By skennedy Date 2013-12-11 Time 12:28 Rev Time 0.00
Received By skennedy Date 2013-12-11 Time 12:28 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2013-10-18 Cont ID  
Sent By dharvey Date 2013-10-18 Time 16:40 Rev Time 0.00
Received By dharvey Date 2013-10-18 Time 16:23 Sent To  
Notes
2013-10-18 16:40:21THE SUBMITTED DRAWING DOES NOT MEET MINIMUM CODE
 REQUIREMENTS. THE FOLLOWING CORRECTIONS/ADDITIONS SHALL
 BE MADE TO THE DRAWINGS FOR APPROVAL.
 1. BE MORE SPECIFIC AS TO THE SERVICE RISER. IS THE
 INTENT TO SAY THAT EACH UNIT HAS ITS INDIVIDUAL SERVICE
 TYPICAL OF THE ONE SHOWN PLEASE SAT SO.
 2. CIRCUIT DESIGNATION FOR EACH UNIT TO CONFIRM EACH
 A/C SERVICE OUTLET IS SERVED FROM THE CORRESPONDING
 UNIT.
 3. SHOW METER & SERVICE DISCONNECT ON THE EXTERIOR OF
 OF THE FLOOR PLAN
 4. LIVING ROOM SMOKE DETECTOR IN FIRST FLOOR UNIT SHALL
 BE RELOCATED FOR CODE COMPLIANCE.
 5. SHOW EXTERIOR STAIR ILLUMINATION AND SWITCHING TO
 CONFORM WITH FBC
  
 SH CALLED CONTRACTOR TO INFORM HIM OF THESE
 REQUIREMENTS, BUT THERE WAS NO ONE IN THE OFFICE.
 SENT BACK TO BIN R5 BY MA

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2013-06-12 Cont ID  
Sent By dharvey Date 2013-06-12 Time 15:45 Rev Time 0.00
Received By dharvey Date 2013-06-12 Time 15:45 Sent To  
Notes
2013-09-11 08:40:38NEW SHEETS SUBMITTED. JG.
2013-06-12 15:46:156-12-13
 DRAWINGS WERE APPROVED WITH EXCEPTION AS NOTED
 VB

Review Stop HIST HISTORICAL
Rev No 4 Status P Date 2013-12-20 Cont ID  
Sent By fmittner Date 2013-12-20 Time 09:26 Rev Time 0.00
Received By fmittner Date 2013-12-20 Time 09:26 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 3 Status F Date 2013-11-20 Cont ID  
Sent By fmittner Date 2013-11-20 Time 11:17 Rev Time 0.00
Received By fmittner Date 2013-11-20 Time 11:17 Sent To E
Notes
2013-11-20 11:18:11GLAZING MUST BE CLEAR.

Review Stop HIST HISTORICAL
Rev No 2 Status F Date 2013-09-17 Cont ID  
Sent By fmittner Date 2013-09-17 Time 16:21 Rev Time 0.00
Received By fmittner Date 2013-09-17 Time 16:21 Sent To  
Notes
2013-09-17 16:23:53PLEASE SPECIFY FRAME COLOR AND GLAZING COLOR (WHITE
 FRAMES/CLEAR GLASS). THREE WINDOWS ON FRONT ELEVATION
 MUST HAVE VERTICAL ORIENTATION TO MATCH WINDOWS ON
 OTHER ELEVATIONS. WINDOW ON FIRST FLOOR SOUTH SIDE OF
 REAR ELEVATION MUST MATCH ADJACENT WINDOW IN SIZE AND
 PROPORTION.

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2013-06-07 Cont ID  
Sent By fmittner Date 2013-06-07 Time 12:21 Rev Time 0.00
Received By fmittner Date 2013-06-07 Time 12:21 Sent To  
Notes
2013-06-07 12:22:50PLEASE PROVIDE EXTERIOR ELEVATIONS (TYPE AND GRID
 PATTERN) AND PRODUCT APPROVALS (MATERIALS) FOR WINDOWS
 SO STAFF CAN DETRMINE COMPLIANCE WITH HISTORIC
 PRESERVATION ORDINANCE. QUESTIONS CONTACT FRIEDERIKE
 822-1457.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2013-12-11 Cont ID  
Sent By skennedy Date 2013-12-11 Time 12:32 Rev Time 0.00
Received By skennedy Date 2013-11-08 Time 07:59 Sent To  
Notes
2013-11-12 07:59:33SENT TO ZONING BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-10-22 Cont ID  
Sent By rmcdouga Date 2013-10-22 Time 15:52 Rev Time 0.00
Received By rmcdouga Date 2013-09-11 Time 09:00 Sent To  
Notes
2013-09-11 09:01:16SENT TO R5 SHELF FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-06-27 Cont ID  
Sent By rmcdouga Date 2013-06-27 Time 16:57 Rev Time 0.00
Received By rmcdouga Date 2013-05-16 Time 15:14 Sent To  
Notes
2013-05-16 15:14:53INCOMING SENT TO R03 BOX . JW

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2013-11-12 Cont ID  
Sent By rmcdouga Date 2013-11-12 Time 10:39 Rev Time 0.00
Received By rmcdouga Date 2013-11-12 Time 10:39 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2013-10-22 Cont ID  
Sent By rmcdouga Date 2013-10-22 Time 12:33 Rev Time 0.00
Received By rmcdouga Date 2013-10-22 Time 12:16 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2013-06-26 Cont ID  
Sent By rmcdouga Date 2013-06-26 Time 16:56 Rev Time 0.00
Received By rmcdouga Date 2013-06-26 Time 16:56 Sent To  
Notes
2013-09-11 08:40:00NEW SHEETS SUBMITTED. JG.

Review Stop P PLUMBING
Rev No 3 Status P Date 2013-11-12 Cont ID  
Sent By rmcdouga Date 2013-11-12 Time 10:40 Rev Time 0.00
Received By rmcdouga Date 2013-11-12 Time 10:40 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2013-10-22 Cont ID  
Sent By rmcdouga Date 2013-10-22 Time 12:33 Rev Time 0.00
Received By rmcdouga Date 2013-10-22 Time 12:15 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2013-06-26 Cont ID  
Sent By rmcdouga Date 2013-06-26 Time 15:25 Rev Time 0.00
Received By rmcdouga Date 2013-06-26 Time 15:25 Sent To  
Notes
2013-09-11 08:40:16NEW SHEETS SUBMITTED. JG.

Review Stop Z ZONING
Rev No 4 Status P Date 2013-11-20 Cont ID  
Sent By fmittner Date 2013-11-20 Time 11:17 Rev Time 0.00
Received By fmittner Date 2013-11-12 Time 12:30 Sent To  
Notes
2013-11-12 12:31:0011/12/13 - ZONING RECEIVED. SENT TO FM FOR HIST AND Z
 REVIEW. LL

Review Stop Z ZONING
Rev No 3 Status F Date 2013-09-17 Cont ID  
Sent By fmittner Date 2013-09-17 Time 16:20 Rev Time 0.00
Received By fmittner Date 2013-09-17 Time 16:20 Sent To  
Notes
2013-09-17 16:21:00OFF ATREET PARKING SPACES MUST BE STRIPED AND
 DIMENSIONS ON THE PLANS.
2013-09-16 19:34:409/6/13

Review Stop Z ZONING
Rev No 2 Status F Date 2013-07-24 Cont ID  
Sent By fmittner Date 2013-07-18 Time 10:08 Rev Time 0.00
Received By fmittner Date 2013-07-18 Time 10:08 Sent To  
Notes
2013-07-24 08:56:49MUST PROVIDE FOUR OFF STREET PARKING SPACES.
2013-07-18 10:13:16AFTER RECORD RESEARCH AND SITE VISIT WITH ANGELLA
 JONES-VANN, DETERMINED THAT TWO UNITS ARE PERMITTED IN
 REAR STRUCTURE DUE TO REDUCTION FROM 4 UNITS TO 2 UNITS
 IN FRONT STRUCTURE.

Review Stop Z ZONING
Rev No 1 Status F Date 2013-06-07 Cont ID  
Sent By fmittner Date 2013-06-07 Time 12:18 Rev Time 0.00
Received By fmittner Date 2013-05-20 Time 15:43 Sent To  
Notes
2013-06-07 12:20:52SF14-C2 ZONING DISTIRCT. OWNER NEEDS TO DEMONSTRATE
 THAT THESE UNTIS HAVE BEEN IN USE. TOO MANY UNITS ON
 SITE. FRIEDERIKE 822-1457 SPOKE TO MATT 613-2444. WILL
 ASK BUILDING INSPECTOR TO GO OUT AND CONFIRM STATUS OF
 UNITS.
  
 SEE SECTION 94-513
  
 (C)
  
 DESTRUCTION OR DISCONTINUANCE.
  
 (1)
  
 A NONCONFORMING STRUCTURE OR BUILDING, OR A CONFORMING
 STRUCTURE OR BUILDING OCCUPIED BY A MAJOR USE
 NONCONFORMITY, WHICH IS DESTROYED MAY NOT BE REPLACED
 EXCEPT IN CONFORMITY WITH THE REQUIREMENTS OF THIS
 CHAPTER.
  
 (2)
  
 A CONFORMING STRUCTURE OR BUILDING OCCUPIED BY A MINOR
 USE NONCONFORMITY MAY BE REPLACED BY A NEW STRUCTURE OR
 BUILDING OF THE SAME OR LESSER SIZE AND REOCCUPIED BY
 THE SAME USE PROVIDED REPLACEMENT IS COMMENCED WITHIN
 12 MONTHS OF THE DESTRUCTION.
  
 (3)
  
 IF A MINOR USE NONCONFORMITY IS ABANDONED FOR A PERIOD
 OF MORE THAN 180 CONSECUTIVE DAYS, SUCH USE SHALL
 THEREAFTER CONFORM TO THE STANDARDS OF THIS CHAPTER.
  
 (4)
  
 IF A MAJOR USE NONCONFORMITY IS ABANDONED FOR A PERIOD
 OF MORE THAN 30 CONSECUTIVE DAYS, SUCH USE SHALL
 THEREAFTER CONFORM TO THE STANDARDS OF THIS CHAPTER.
  