Plan Review Details - Permit 13050558
| Plan Review Stops For Permit 13050558 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2013-06-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-06-26 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-06-26 |
Time |
11:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2013-05-23 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-05-23 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-05-23 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2013-05-23 11:20:14 | 5-23-13 | | | APPROVED WITH EXCEPTION. SEE NOTES ON SKETCH. | | | VB |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2013-06-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-06-26 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-06-26 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2013-06-26 13:41:56 | A SEPARATE PERMIT, APPLICATION AND REVIEW IS REQUIRED | | | FOR A GAS PERMIT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-07-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-07-10 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-07-02 |
Time |
08:49 |
Sent To |
|
|
| Notes |
| 2013-07-02 08:49:41 | TO RM DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-06-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-06-26 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-05-16 |
Time |
10:13 |
Sent To |
|
|
| Notes |
| 2013-05-17 10:18:07 | SENT TO R1 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2013-07-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-07-10 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-07-10 |
Time |
08:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2013-06-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-06-26 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-06-26 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2013-06-26 13:39:40 | 2010 FBC | | | | | | DENIED BY PLUMBING | | | | | | 1) SPECIFY THE SCOPE OF THE PLUMBING WORK ON THE PLANS. | | | CITY AMENDMENTS 107.2.1 | | | | | | 2) IF PLUMBING FIXTURES ARE RELOCATED OR ADDED, SUBMIT | | | TWO COPIES OF A PLUMBING RISER DIAGRAM. SPECIFY THE | | | PIPE SIZES FOR ALL DRAIN, WASTE AND VENT PIPING. CITY | | | AMENDMENTS 107.3.5.3 AND 107.2.1 | | | | | | 3) THE PRINTED NAME, SIGNATURE AND LICENSE NUMBER OF | | | THE PERSON RESPONSIBLE FOR THE DESIGN IS REQUIRED ON | | | THE DRAWINGS. CITY AMENDMENTS 107.2.1 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
|