| Plan Review Stops For Permit 13050282 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2013-08-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-08-09 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-08-08 |
Time |
17:57 |
Sent To |
|
|
| Notes |
| 2013-08-08 18:00:05 | APPROVED WITH EXCEPTION. PLANS HAVE BEEN RED-LINED. | | | ALTHOUGH THE ORIGINAL PLANS WERE PERMITTED UNDER THE | | | 2007 FLORIDA BUILDING CODE, THE REVISED PLANS REFERENCE | | | THE 2010 FBC. THE SCOPE OF WORK IS NOT ADVERSELY | | | AFFECTED BY THIS DIFFERENCE. THE PRODUCT APPROVALS THAT | | | WERE ORIGINALLY SUBMITTED AND APPROVED MEET THE | | | WIND-LOAD REQUIREMENTS OF BOTH OF THESE CODE EDITIONS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-06-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-06-03 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-05-31 |
Time |
11:38 |
Sent To |
|
|
| Notes |
| 2013-06-03 08:32:08 | 2007 FBC | | | | | | DENIED BY BUILDING | | | | | | 1) THE ORIGINAL PERMIT FOR THIS JOB WAS APPLIED FOR | | | UNDER THE 2007 FLORIDA BUILDING CODE (BASIC WIND SPEED | | | 140), THEREFORE, THE REVISIONS TO THESE PLANS ARE | | | REQUIRED TO COMPLY WITH THE 2007 FBC. FBCR 301.2.1 | | | PLEASE CORRECT THE DESIGN DATA ON SHEET A-1. | | | | | | 2) THE REVISED PLANS SHOW HABITABLE SPACE ON THE FIRST | | | FLOOR WHERE THE APPROVED PLANS HAD STORAGE. THE PLANS | | | WILL BE REQUIRED TO BE REVIEWED BY PALM BEACH COUNTY TO | | | DETERMINE IF IMPACT FEES ARE DUE BEFORE THIS REVISION | | | CAN BE APPROVED. | | | | | | NOTE: WHEN SUBMITTING THE CORRECTED REVISION, INFORM | | | THE INTAKE PERSON THAT YOU ARE RESUBMITTING A DENIED | | | REVISION. YOU WILL ONLY BE CHARGED FOR THE CORRECTED | | | PAGES. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2013-08-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-08-09 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-08-09 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2013-08-09 09:20:46 | APPROVED WITH EXCEPTIONS. PLANS HAVE BEEN RED-LINED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2013-05-17 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-05-17 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-05-17 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2013-05-17 16:23:25 | RECPT FOR GDO SHOULD BE GFI PER NEC 210.8.A.2. THERE | | | ARE NO EXCEPTIONS LISTED | | | COMBINATION SMOKE/ CO DETECTORS REQUIRED PER R315 OF | | | THE FBC | | | SMOKE/CO DETECTOR REQUIRED AT TOP AND BOTTOM OF STAIRS | | | AFCI PROTECTION REQUIRED PER NEC 210.12B | | | VB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-08-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-08-09 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-08-06 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2013-08-07 15:36:14 | INCOMING SENT TO R MCDOUGALS' DESK . JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-06-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-06-03 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-05-08 |
Time |
14:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2013-08-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-08-09 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-08-09 |
Time |
10:17 |
Sent To |
|
|
| Notes |
| 2013-08-09 10:17:10 | MU 2013-14624, COPY OF RECEIPT WAS EMAILED TO ME FROM | | | WILLIE SWOOPE AT P.B.C. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2013-08-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-08-09 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-08-09 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2013-08-09 09:23:45 | A COPY OF THE PAID IMPACT FEE RECEIPT IS REQUIRED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2013-06-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-06-03 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-06-03 |
Time |
08:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2013-05-14 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2013-05-14 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2013-05-14 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2013-05-10 10:48:19 | 5/10/13 |
|
|