| 2013-05-07 10:22:13 | BUILDING PLAN REVIEW |
| | PERMIT: 13050161 |
| | ADD: 804 SOUTHERN BLVD |
| | CONT: H. C. TURNER |
| | TEL: (866)770-6664 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: MAY 07/ 2013 |
| | ACTION: DENIED |
| | |
| | NOTE: PERMIT# 13040633 TENANT SEPERATION WALL SUITE # |
| | 848 ALREADY EXIST. |
| | |
| | 1) CONTRACTOR H C TURNER NEEDS TO UPDATE THEIR GENERAL |
| | LIABILITY AND WORKERS COMP INSURANCE. |
| | |
| | 2) PROVIDE A FLOOR PLAN INDICATING WHAT STOREFRONT IS |
| | BEING REPLACED FOR THE VALUE OF $4,600.00 DOLLARS THIS |
| | MAY APPEAR LOW FOR THE AMOUNT OF WORK TO BE COMPLETED |
| | UNDER THIS PERMIT. W P B ADMINISTRTIVE CODE 108.2 |
| | SCHEDULE OF PERMIT FEES. ON BUILDINGS, STRUCTURES, |
| | ELECTRICAL, GAS, MECHANICAL, AND PLUMBING SYSTEMS OR |
| | ALTERATIONS REQUIRING A PERMIT, A FEE FOR EACH PERMIT |
| | SHALL BE PAID AS REQUIRED, IN ACCORDANCE WITH THE |
| | SCHEDULE ESTABLISHED BY THE APPLICABLE GOVERNING |
| | AUTHORITY. |
| | |
| | 108.3* BUILDING PERMIT VALUATION. |
| | IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE |
| | CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, |
| | ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS |
| | APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE |
| | PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, |
| | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL |
| | REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND |
| | SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE |
| | STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR |
| | FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR |
| | BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING |
| | COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. |
| | VALUATION REFRENCES MAY INCLUDE THE LATEST PUBLISHED |
| | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES |
| | (MARSHALL-SWIFT, MEANS, ETC) WITH REGIONAL ADJUSTMENTS |
| | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE |
| | CONGRESS. |
| | |
| | 3) PLEASE PROVIDE NOT ONLY FLOOR PLAN BUT ELEVATIONS |
| | PLEASE PROVIDE WIDTH OF GLAZING UNITS AS WELL AS |
| | HEIGHTS. WITHIN THE PRODUCT APPROVAL FOR BOTH THE DOOR |
| | AND STOREFRONT WINDOWS PLEASE CIRCLE THE TYPE OF GLASS |
| | TO BE INSTALLED, CIRCLE THE WIDTH & HEIGHT OF GLASS, |
| | THE SAME FOR MULLIONS, IF REINFORCEMENT IS REQUIRED, |
| | AND PRESSURES FOR OPENINGS. 2010 FBC-B 1609.1.2 |
| | PROTECTION OF OPENINGS, 1609.6.4.41 COMPONENTS & |
| | CLADDING |
| | |
| | 4) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS |
| | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| | SHOP DRAWINGS ETC.. |
| | |
| | 5) 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN- |
| | CHAPTER 6 OF ASCE 7-10. |
| | 1609.3 BASIC WIND SPEED FIGURE 1609.A-C |
| | 1609.3 WIND SPEED CONVERSION |
| | 5.1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN |
| | ACCORDANCE WITH 1609.3.1 & ASCE 7-10 |
| | |
| | 5.2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10. |
| | |
| | 5.3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN |
| | ACCORDANCE WITH 1609.4 & ASCE 7-10 |
| | |
| | 5.4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * |
| | SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | 5.5) COMPONENTS & CLADDING PRESSURES POSITVE & NEGATIVE |
| | TABLE 1609.2(2) . |
| | |
| | |
| | |