Plan Review Details - Permit 13050102
| Plan Review Stops For Permit 13050102 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2013-05-31 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-05-31 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-05-31 |
Time |
16:55 |
Sent To |
|
|
| Notes |
| 2013-05-31 16:57:49 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. PERMIT APPLICATION IS INCOMPLETE. PROVIDE SQUARE | | | FOOT AREA. | | | | | | 2. VALUE IS TO INCLUDE LABOR AND MATERIALS, FBC 109. | | | PROVIDE A COPY OF THE CONTRACT. A COST BREAKDOWN MAY BE | | | REQUIRED. | | | | | | THIS COMMENT MAY BE ADDRESSED VIA EMAIL. CONTRACTOR WAS | | | CONTACTED ON 5/30. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2013-05-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-05-30 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-05-30 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2013-05-30 11:48:17 | PROVISO - MFGR TO EMAIL ASTM E 84 TEST RESULTS UPON | | | COMPLETION | | | ISSUED AT CONTRACTOR'S RISK | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-05-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-05-07 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-05-07 |
Time |
12:43 |
Sent To |
|
|
| Notes |
| 2013-05-07 12:46:24 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | | | SEE 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM | | | E 84 OR UL 723. | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-05-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-05-07 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-05-03 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2013-05-03 11:52:16 | TO BLDG < $5K |
|
|
|