Plan Review Details - Permit 13050007
Plan Review Stops For Permit 13050007
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2013-07-24 Cont ID  
Sent By shill Date 2013-07-24 Time 15:17 Rev Time 0.00
Received By shill Date 2013-07-24 Time 15:17 Sent To  
Notes
2013-07-24 15:20:00****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 COURTESY REVIEW -
  
 FBC RESIDENTIAL 2010 310.1 EXCEPTION 2 REQUIRES A
 SCREEN ENCLOSURE OPEN TO THE ATMOSPHERE. THE ENCLOSURE
 PROPOSED HAS A HARD ROOF AND WALLS. SEE ALSO THE FOUR
 NONBINDING BOAF INTERPRETATIONS REGARDING THIS TOPIC
 WHICH CONFIRM THAT "OPEN TO THE ATMOSPHERE" REQUIRES
 SCREEN WALLS AND ROOF. AS DISCUSSED, THE
 INTERPRETATIONS ARE AVAILABLE ON THE INTERNET
 WWW.FLORIDABUILDING.ORG, OR I WILL SCAN AND EMAIL TO
 YOU UPON REQUEST.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2013-07-10 Cont ID  
Sent By shill Date 2013-07-10 Time 08:49 Rev Time 0.00
Received By shill Date 2013-07-05 Time 15:34 Sent To  
Notes
2013-07-10 08:52:33****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 FROM PREVIOUS LIST:
  
 1. OK
  
 2. REVISE PLAN TO SHOW OPENINGS FROM THE HOUSE INTO THE
 EXISTING PORCH AS WELL AS ROOM DESIGNATIONS. IF A
 BEDROOM OPENS INTO THE EXISTING PORCH, SHOW ALTERNATIVE
 MEANS OF EMERGENCY ESCAPE AND RESCUE FBC R 310 (TYPE OF
 OPENING AND DIMENSIONS OF CLEAR OPENING).
  
 2ND REVIEW, PLAN DOES NOT PROVIDE WINDOW CLEAR OPENING
 DIMENSION AND DOES NOT SHOW THAT (BASED ON AERIALS)
 THERE IS A DOOR FROM THE BEDROOM TO THE EXISTING OPEN
 AREA, NOW PROPOSED TO BE ENCLOSED WITH A PORCH (ROOF
 PANELS, ACRYLIC WALL PANELS). IT APPEARS THAT YOU
 PROPOSE TO REDUCE THE LEVEL OF SAFETY BY ELMINATING A
 COMPLIANT EMERGENCY MEANS OF ESCAPE.
  
 AS SPECIFIC METHOD OF COMPLIANCE WAS NOT STATED (FBC
 2010 EXISTING BUILDING CODE 101.5), A SPECIFIC CODE
 SECTION CANNOT BE PROVIDED. PLEASE FEEL FREE TO CONTACT
 ME IF YOU NEED FURTHER ASSISTANCE.
  
 3RD REVIEW - EXISTING WINDOW DOES NOT COMPLY WITH
 EMERGENCY ESCAPE AND RESCUE OPENINGS. THE EXISTING
 SLIDING GLASS DOOR DOES COMPLY. YOU NOW PROPOSED TO
 ENCLOSE THE PORCH WITH SOLID ACRYLIC PANELS, SO THE
 SLIDING GLASS DOOR WILL NO LONGER SERVE AS A COMPLIANT
 EMERGENCY ESCAPE AND RESCUE.
  
 A COMPLIANT WINDOW IS SUGGESTED (CASEMENT, HORIZONTAL
 ROLLER).
  
 PLEASE ALSO NOTE THAT THERE ARE THREE DIFFERENT BOAF
 INFORMAL INTERPRETATIONS WHICH ADDRESS THIS ISSUE.
  
 PLEASE FEEL FREE TO CONTACT ME TO DISCUSS.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2013-06-14 Cont ID  
Sent By shill Date 2013-06-14 Time 15:20 Rev Time 0.00
Received By shill Date 2013-06-14 Time 15:20 Sent To  
Notes
2013-06-14 15:23:41****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 FROM PREVIOUS LIST:
  
 1. OK
  
 2. REVISE PLAN TO SHOW OPENINGS FROM THE HOUSE INTO THE
 EXISTING PORCH AS WELL AS ROOM DESIGNATIONS. IF A
 BEDROOM OPENS INTO THE EXISTING PORCH, SHOW ALTERNATIVE
 MEANS OF EMERGENCY ESCAPE AND RESCUE FBC R 310 (TYPE OF
 OPENING AND DIMENSIONS OF CLEAR OPENING).
  
 2ND REVIEW, PLAN DOES NOT PROVIDE WINDOW CLEAR OPENING
 DIMENSION AND DOES NOT SHOW THAT (BASED ON AERIALS)
 THERE IS A DOOR FROM THE BEDROOM TO THE EXISTING OPEN
 AREA, NOW PROPOSED TO BE ENCLOSED WITH A PORCH (ROOF
 PANELS, ACRYLIC WALL PANELS). IT APPEARS THAT YOU
 PROPOSE TO REDUCE THE LEVEL OF SAFETY BY ELMINATING A
 COMPLIANT EMERGENCY MEANS OF ESCAPE.
  
 AS SPECIFIC METHOD OF COMPLIANCE WAS NOT STATED (FBC
 2010 EXISTING BUILDING CODE 101.5), A SPECIFIC CODE
 SECTION CANNOT BE PROVIDED. PLEASE FEEL FREE TO CONTACT
 ME IF YOU NEED FURTHER ASSISTANCE.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-05-14 Cont ID  
Sent By shill Date 2013-05-14 Time 17:25 Rev Time 0.00
Received By shill Date 2013-05-14 Time 17:25 Sent To  
Notes
2013-05-14 17:28:30****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. PROVIDE A SITE PLAN WHICH SHOWS LOCATION OF PROPOSED
 IMPROVEMENT AND PROXIMITY TO PROPERTY LINES AND OTHER
 STRUCTURES, FBC R 302.
  
 2. REVISE PLAN TO SHOW OPENINGS FROM THE HOUSE INTO THE
 EXISTING PORCH AS WELL AS ROOM DESIGNATIONS. IF A
 BEDROOM OPENS INTO THE EXISTING PORCH, SHOW ALTERNATIVE
 MEANS OF EMERGENCY ESCAPE AND RESCUE FBC R 310 (TYPE OF
 OPENING AND DIMENSIONS OF CLEAR OPENING).
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2013-07-10 Cont ID  
Sent By shill Date 2013-07-10 Time 08:52 Rev Time 0.00
Received By shill Date 2013-06-27 Time 10:41 Sent To  
Notes
2013-07-01 10:41:55SENT TO SAMANTHA'S DESK FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-06-14 Cont ID  
Sent By shill Date 2013-06-14 Time 15:20 Rev Time 0.00
Received By shill Date 2013-06-11 Time 08:28 Sent To  
Notes
2013-06-11 08:29:39INCOMING SENT TO SAMANTHAS DESK. JW

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-05-14 Cont ID  
Sent By shill Date 2013-05-14 Time 17:28 Rev Time 0.00
Received By shill Date 2013-05-01 Time 10:47 Sent To  
Notes
2013-05-02 10:47:58SENT TO ZONING SHELF FOR REVIEW. JG.

Review Stop Z ZONING
Rev No 1 Status P Date 2013-05-13 Cont ID  
Sent By eschneid Date 2013-05-13 Time 14:40 Rev Time 0.00
Received By jroach Date 2013-05-10 Time 14:08 Sent To B
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved