| Plan Review Stops For Permit 13041122 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2013-07-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-07-29 |
Time |
17:13 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-07-29 |
Time |
17:13 |
Sent To |
|
|
| Notes |
| 2013-07-29 18:01:03 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR: A)ALL | | | SIMPSON STRUCTURAL CONNECTORS SPECIFIED BY THE ENGINEER | | | ON PLANS AND DETAILS (NOTE: PROVIDE ONLY THE PRODUCT | | | APPROVAL COVER PAGE AND PAGE SHOWING THE SPECIFIED | | | CONNECTOR). B)METAL SIDING AS SPECIFIED ON NOTE # 4 ON | | | SHEET A2. | | | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL THE PRODUCT APPROVALS | | | SUBMITTED. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2013-07-11 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-07-10 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-07-10 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2013-07-10 09:21:27 | RESIDENTIAL (R3) RENOVATIONS, BUILDING REVIEW SECOND | | | CHECKLIST. | | | CODE: 2010 FBC | | | | | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | DCA RULE 9N-3: | | | A) ROOF RIDGE VENT AS SPECIFIED ON THE HCD | | | "SPECIFICATIONS" BOOKLET. | | | | | | B) SINGLE HUNG WINDOWS. FLORIDA PRODUCT APPROVAL | | | FL14604-R2 SUBMITTED DOESN'T MEET THE DESIGN PRESSURES | | | CALCULATED BY THE ENGINEER ON SHEET A2 SUBMITTED. SEC. | | | R301.1 OF 2010 FBC-RESIDENTIAL. | | | | | | C) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED BY THE | | | ENGINEER ON PLANS AND DETAILS SUBMITTED. | | | | | | D) METAL SIDING AS SPECIFIED ON NOTE # 4 OF FRAMING | | | LEGEND ON SHEET A2. | | | | | | 2- ENGINEER WHO PRODUCED THE PLANS TO REVIEW AND | | | APPROVE IN WRITING (NOT SIGNING AND SEALING) ALL THE | | | PRODUCT APPROVALS AS REQUIRED BY SEC. 107.3.4.1 OF CITY | | | AMENDMENTS TO FBC. | | | | | | 3- ENGINEER TO PROVIDE SPECIFICATIONS ON PLANS FOR THE | | | NEW ROOF RIDGE VENT AS SPECIFIED ON THE "HCD | | | SPECIFICATIONS BOOKLET". SEE SEC. R806 OF 2010 | | | FBC-RESIDENTIAL. | | | | | | 4- ORIGINAL COMMENT: CITY HCD "SPECIFICATIONS" SPECIFY | | | NEW PULL DOWN STAIRS FOR ATTIC ACCESS. CLARIFY IF THERE | | | IS AN EXISTING PULL DOWN STAIRS. IF NOT, THEN NEED TO | | | PROVIDE ENGINEERING SHOWING THAT EXISTING ATTIC IS | | | ADEQUATE TO RECEIVE THE NEW STAIRS AND THAT THE ATTIC | | | IS DESIGNED TO RESIST THE NEW STORAGE LOAD REQUIRED BY | | | TABLE R301.5 OF 2010 FBC-RESIDENTIAL. SEC. 107.2.1.3 OF | | | CITY AMENDMENTS TO FBC. | | | | | | RESPONSE: THERE IS NO RESPONSE TO THIS ITEM. ENGINEER'S | | | PLANS SUBMITTED DIDN'T ADDRESS THIS ISSUE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-05-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-05-16 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-05-16 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2013-05-16 15:23:42 | RESIDENTIAL (R3) REPAIRS BUILDING REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW TO DO ALL THE WORK SPECIFIED ON THE | | | "SPECIFICATIONS" BOOKLET SUBMITTED. SEC. 109.3 CITY | | | AMENDMENTS TO FBC. | | | *** PROVIDE COPY OF SIGNED CONTRACT WITH CITY HOUSING | | | AND COMMUNITY DEVELOPMENT AGENCY (HCD). | | | | | | 2- BEDROOM WINDOWS: SPECIFY TYPE AND SIZE OF EXISTING | | | WINDOWS AND TYPE AND SIZE OF PROPOSED WINDOWS TO VERIFY | | | COMPLIANCE WITH SEC. 601.2 AND SEC. 604 OF 2010 | | | FBC-EXISTING BUILDING. | | | | | | 3- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | DCA RULE 9N-3: | | | A) ROOF RIDGE VENT AS SPECIFIED ON THE HCD | | | "SPECIFICATIONS" BOOKLET. | | | | | | B) SINGLE HUNG WINDOWS. NOA 10-0428.02 SUBMITTED WAS | | | SUPERSEDED BY MIAMI-DADE. VISIT THE MIAMI-DADE WEBSITE | | | AND DOWNLOAD CURRENT NOA. | | | | | | C) WINDOW MULLIONS IF THERE ARE ANY WINDOWS THAT ARE | | | GOING TO BE MULLED TOGETHER. | | | | | | 4- CITY HCD "SPECIFICATIONS" SPECIFY NEW PULL DOWN | | | STAIRS FOR ATTIC ACCESS. CLARIFY IF THERE IS AN | | | EXISTING PULL DOWN STAIRS. IF NOT, THEN NEED TO PROVIDE | | | ENGINEERING SHOWING THAT EXISTING ATTIC IS ADEQUATE TO | | | RECEIVE THE NEW STAIRS AND THAT THE ATTIC IS DESIGNED | | | TO RESIST THE NEW STORAGE LOAD REQUIRED BY TABLE R301.5 | | | OF 2010 FBC-RESIDENTIAL. SEC. 107.2.1.3 OF CITY | | | AMENDMENTS TO FBC. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2013-08-07 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-08-07 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-08-07 |
Time |
17:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2013-07-02 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-07-02 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-07-02 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2013-07-02 09:31:17 | 13041122 | | | 716 48TH ST. | | | REWIRE EXISTING HOUSE | | | | | | PLEASE PROVIDE DETAILED ELECTRICAL PLAN FOR ALL | | | IMPROVEMENTS. | | | | | | INDICATE THE SIZE, RATING, LOCATION OF THE EXISTING | | | SERVICE, MAIN DISCONNECT AND PANELBOARD. SHOW SERVICE | | | AND PANEL BOARD LOCATIONS. SHOW NEW AND EXISTING | | | OUTLETS. INCLUDE A PANEL SCHEDULE. NEC 215.5 | | | | | | ALL NEW GENERAL PURPOSE OUTLETS MUST BE AFCI PROTECTED. | | | NEC 210.12 | | | | | | NEW RECEPTACLES MUST BE TAMPER RESISTANT. NEC 406.11 | | | | | | REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO | | | INCLUDE INTERCONNECTED SMOKE DETECTORS. IF THE | | | RESIDENCE HAS GAS APPLIANCES, AN ATTACHED GARAGE OR A | | | FIRE PLACE A CARBON MONOXIDE DETECTOR IS REQUIRED | | | WITHIN TEN FEET OF EACH ROOM USED FOR SLEEPING. FBC | | | R313 | | | | | | ADDITIONAL RECEPTACLES MAY BE REQUIRED IN THE BEDROOMS | | | AND HALLWAY. ADD RECEPTACLES SO THAT NO WALL SPACE IS | | | MORE THAN 6 FEET FROM A RECEPTACLE AND ALL WALL SPACES | | | MORE THAN 2 FEET IN WIDTH HAVE A RECEPTACLE. NEC 210.52 | | | | | | THE LIVING AREA REQUIRES A SWITCHED RECEPTACLE OR LIGHT | | | AND SWITCH CONTROLLED OUTSIDE LIGHTS. NEC 210.70 | | | | | | A BONDING STRIP IS REQUIRED AT SERVICE GROUND NEC | | | 250.94 | | | | | | GFCI PROTECTED RECEPTACLES ARE REQUIRED AT FRONT AND | | | REAR ELEVATIONS. NEC 210.8 | | | | | | PROVIDE TWO OR MORE 20- AMPERE SMALL APPLIANCE BRANCH | | | CIRCUITS. NEC 210.52 | | | | | | PROVIDE A 20 AMPERE BRANCH CIRCUIT FOR THE BATHROOMS. | | | NEC 210.11 (C)(3) | | | | | | | | | ROBERT LECKY | | | ELECTRICAL PLANS EXAMINER | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2013-05-03 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-05-03 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-05-03 |
Time |
09:58 |
Sent To |
|
|
| Notes |
| 2013-05-03 09:59:13 | PLEASE PROVIDE AN ENGINEERED DRAWING SHOWING ALL WORK | | | TO BE DONE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-08-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-08-07 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-07-19 |
Time |
16:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-07-11 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-07-11 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-06-17 |
Time |
09:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-05-28 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2013-05-28 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2013-04-29 |
Time |
09:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
N |
Date |
2013-08-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-08-12 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-08-12 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2013-08-12 11:30:40 | PROVIDE COMPLETE INFORMATION UNDER A SEPARATE PERMIT. | | | JG. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2013-07-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-07-29 |
Time |
18:30 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-07-29 |
Time |
18:12 |
Sent To |
|
|
| Notes |
| 2013-07-29 18:45:40 | RESIDENTIAL (R3) RENOVATION, MECHANICAL REVIEW | | | COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- ENGINEER SHOWN ON THE A/C PLAN TITLE BLOCK TO SIGN | | | AND DATE DRAWING AS REQUIRED BY CHAPTER 471 FLORIDA | | | STATUTE. | | | | | | 2- A/C PLAN: SPECIFY THE CFM FOR EACH ROOM TO VERIFY | | | COMPLIANCE WITH THE BALANCED RETURN AREA SEC. M1602.4 | | | OF 2010 FBC-RESIDENTIAL. | | | | | | 3- RETURN AIR CAN'T BE TAKEN FROM THE KITCHEN. SEC. | | | M1602.2 OF 2010 FBC-RESIDENTIAL. CLEARLY SHOW ON A/C | | | PLAN RETURN AIR LOCATION AND SIZE. | | | | | | 4- EQUIPMENT SIZING CALCULATIONS SPECIFY UNVENTED | | | ATTIC. THIS ATTIC IS VENTED. SEE PLANS SUBMITTED. | | | REVISE AS REQUIRED. ALSO, SHOW ON A/C PLAN THE SEER | | | REQUIRED BY THE EQUIPMENT SIZING CALCULATIONS | | | SUBMITTED. SEC. 403.6 OF 2010 FBC-ENERGY CONSERVATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2013-07-11 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-07-11 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-07-11 |
Time |
15:38 |
Sent To |
|
|
| Notes |
| 2013-07-11 16:04:29 | 1- NO INFORMATION SUBMITTED NOW. PROVIDE COMPLETE A/C | | | INFORMATION UNDER A SEPARATE PERMIT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2013-05-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-05-16 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-05-16 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2013-05-16 14:40:44 | RESIDENTIAL (R3) MECHANICAL REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- PROVIDE COMPLETE A/C PLANS AND COMPLETE EQUIPMENT | | | SIZING CALCULATIONS (2 COPIES). SEC. 403.6 OF 2010 | | | FBC-ENERGY CONSERVATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2013-05-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-05-16 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-05-16 |
Time |
15:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2013-05-28 |
|
|
Cont ID |
|
| Sent By |
avann |
Date |
2013-05-28 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2013-05-28 |
Time |
10:24 |
Sent To |
|
|
| Notes |
| 2013-05-28 10:25:06 | HCD PROJECT 50% RULE DOES NOT APPLY | | 2013-05-06 10:36:33 | 5/3/13 |
|
|