| Plan Review Stops For Permit 13041087 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2013-06-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-06-10 |
Time |
08:04 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-06-10 |
Time |
07:16 |
Sent To |
|
|
| Notes |
| 2013-06-10 08:54:36 | 2010 FBC | | | | | | REVISIONS REQUIRED | | | | | | THE WORK ON THIS PROJECT WAS DONE WITHOUT PERMITS OR | | | INSPECTIONS. THE FOLLOWING ITEMS WILL BE SUBMITTED AND | | | APPROVED PRIOR TO FINAL INSPECTION. | | | | | | 1) ENERGY CALCULATIONS (FBC ENERGY 402) | | | | | | 2) FOUNDATION DETAILS (FBC R403) | | | | | | 3) PRODUCT APPROVALS FOR STRUCTURAL CONNECTORS (DCA | | | RULE 9N-3) | | | | | | 4) PRODUCT APPROVALS FOR METAL ROOF (DCA RULE 9N-3) | | | | | | 4) EXTERIOR WALL SHEATHING (FBC R703.1.2) | | | | | | 5) EXTERIOR WALL WATER RESISTIVE BARRIER (FBC R703.2) | | | | | | 6) DETAILS OF UNDER FLOOR SPACE SHOWING COMPLIANCE WITH | | | VENTILATION AND ACCESS REQUIREMENTS (FBC R408). |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-05-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-05-14 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-05-13 |
Time |
12:48 |
Sent To |
|
|
| Notes |
| 2013-05-13 13:03:23 | 2010 FBC | | | | | | DENIED BY BUILDING | | | | | | 1) SUBMIT TWO SETS OF ENERGY CALCULATIONS FOR THE | | | ADDITIONS AS REQUIRED BY FBC ENERGY 101.4.3. | | | | | | 2) SHOW COMPLIANCE WITH FBC R806 FOR ROOF VENTILATION. | | | | | | 3) PROVIDE ADDITIONAL DETAILS OF THE FOUNDATIONS FOR | | | THE ADDITIONS SHOWING THAT THEY COMPLY WITH FBC R403.1, | | | R403.1.1, R403.1.2, R403.1.4, R404.1.6, R408.1 AND | | | R408.4. | | | | | | 4) SHOW COMPLIANCE WITH FBC R317.1 FOR PROTECTION OF | | | WOOD JOISTS AND WOOD STRUCTURAL FLOOR MEMBERS. | | | | | | 5) SHOW COMPLIANCE WITH FBC R318.1 FOR TERMITE | | | PROTECTION. | | | | | | 6) SUBMIT TWO SETS OF PRODUCT APPROVALS, AS REQUIRED BY | | | DCA RULE 9N-3, FOR THE SIMPSON CONNECTORS AND THE METAL | | | ROOF SPECIFIED IN ITEM #2 UNDER BUILDING ENVELOPE IN | | | THE SCOPE OF WORK ON SHEET SP-1. | | | | | | 7) THE WALL SECTION APPEARS TO SHOW STRUCTURAL WALL | | | SHEATHING BEHIND THE HARDI-BOARD SIDING. PLEASE CLARIFY | | | AND SPECIFY THE SHEATHING MATERIAL. CITY AMENDMENTS | | | 107.2.1 | | | | | | 8) SHOW COMPLIANCE WITH R703.2 FOR WEATHER-RESISTANT | | | SHEATHING PAPER ON EXTERIOR WALLS. | | | | | | 9) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE | | | MODIFIED BITUMEN ROOF SYSTEM HAS A FLORIDA COVERSHEET | | | (FL# 5680) ATTACHED TO A MIAMI-DADE NOA. THE | | | INSTALLATION REQUIREMENTS ARE DIFFERENT FOR EACH OF | | | THESE. PLEASE CHOOSE THE ONE THAT YOU WANT TO USE AND | | | SUBMIT IT. IF ENHANCED FASTENING OF THE BASE SHEET IS | | | REQUIRED TO ACHIEVE HIGHER UPLIFT FOR THE CORNER AND | | | PERIMETER ROOF AREAS, THEN SUBMIT TWO SETS OF SIGNED | | | AND SEALED RAS 117 CALCULATIONS. DCA RULE 9N-3. | | | | | | 10) SUBMIT TWO SETS OF A KEY PLAN AND AN INSTALLATION | | | SCHEDULE FOR THE STORM PANELS (FL# 10905-R1) THAT WERE | | | SUBMITTED. | | | | | | 11) SHOW COMPLIANCE WITH FBC R314.3.1 FOR INSTALLATION | | | OF SMOKE ALARMS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2013-06-07 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-06-07 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-06-07 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2013-06-07 10:34:50 | 6-7-13 | | | CORRECTIONS MADE | | | VB |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2013-05-03 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-05-03 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-05-03 |
Time |
09:26 |
Sent To |
|
|
| Notes |
| 2013-05-03 09:29:01 | 1. PROVIDE TYPICAL PANEL SCHEDULE SHOWING CIRCUITS AND | | | WIRE SIZES | | | 2. ALL NEW DEVICES SHALL COMPLY WITH NEC 406.11 | | | 3. ALL NEW WIRING MUST COMPLY WITH NEC 210.12B |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-06-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-06-10 |
Time |
08:04 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-06-07 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2013-06-07 12:29:28 | 6/6 TO RM DESK | | 2013-06-07 10:07:23 | TO VB DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-05-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-05-14 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-04-26 |
Time |
17:16 |
Sent To |
|
|
| Notes |
| 2013-04-26 17:16:42 | EXPEDITED | | | R--4 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
P |
Date |
2013-05-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-05-13 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-05-13 |
Time |
10:19 |
Sent To |
|
|
| Notes |
| 2013-05-13 10:19:38 | MU-2013-8463 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2013-06-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-06-10 |
Time |
07:29 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-06-10 |
Time |
07:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2013-05-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-05-13 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-05-13 |
Time |
10:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2013-06-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-06-28 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-06-28 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2013-06-28 11:24:52 | NOA NO. 12-0202.04 GAF LIBERTY SBS SELF-ADHERING | | | BITUMEN ROOF SYSTEM WAS SUBMITTED. SIGNED AND SEALED | | | RAS 117 CALCULATIONS ARE REQUIRED AND WERE NOT | | | SUBMITTED. WORK WAS DONE WITHOUT PERMITS OR | | | INSPECTIONS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2013-05-06 |
|
|
Cont ID |
|
| Sent By |
mdekle |
Date |
2013-05-06 |
Time |
|
Rev Time |
|
| Received By |
mdekle |
Date |
2013-05-06 |
Time |
|
Sent To |
|
|
| Notes |
| 2013-05-06 11:45:59 | APPROVED VIA ZBA3294. PROJECT #Z13020002 | | 2013-05-06 10:35:43 | 5/3/13 |
|
|