Plan Review Details - Permit 13040973
| Plan Review Stops For Permit 13040973 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2013-08-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-08-05 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-08-05 |
Time |
16:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2013-05-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-05-16 |
Time |
17:02 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-05-16 |
Time |
17:02 |
Sent To |
|
|
| Notes |
| 2013-05-16 17:03:53 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. THE FORM TITLED "PRODUCT APPROVAL REVIEW FORM" | | | PROPOSES DESIGN PRESSURES OF +90, -98.7 PSF, BUT THE | | | DESIGN PRESSURES CIRCLED ON THE ENGINEERING ARE HIGHER. | | | PLEASE CORRELATE. | | | | | | 2. ON THE PRODUCT APPROVAL, CIRCLE PROPOSED | | | INSTALLATION DETAILS/CONFIGURATION TO CONFIRM THAT | | | PROPOSED INSTALLATION COMPLIES WITH PROPOSED DESIGN | | | PRESSURES FBC 1609. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-04-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-04-24 |
Time |
17:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-04-24 |
Time |
17:44 |
Sent To |
|
|
| Notes |
| 2013-04-24 17:45:36 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. DESIGN PRESSURES FOR BUILDINGS OVER 60FEET ARE | | | REQUIRED TO BE DESIGNED USING ASCE7, FBC1609.1.1. | | | DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR | | | PUBLIC RECORD ARE TO BE SIGNED SEALED ORIGINALS | | | FAC61G15-23.002. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-08-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-08-05 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-07-25 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2013-07-26 16:26:39 | SENT TO SAMANTHA'S DESK FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-05-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-05-16 |
Time |
17:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-05-07 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2013-05-08 10:34:47 | SENT TO SAMANTHA'S DESK FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-04-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-04-24 |
Time |
17:45 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-04-24 |
Time |
17:45 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy