| Plan Review Stops For Permit 13040935 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2013-06-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-06-24 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-06-24 |
Time |
14:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-06-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-06-12 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-06-11 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2013-06-12 09:05:38 | 2010 FBC | | | | | | DENIED BY BUILDING | | | | | | 1) PROVIDE A SITE PLAN OR SURVEY THAT SPECIFIES THE | | | DISTANCE TO THE PROPERTY LINE ON THE SIDE OF THE GARAGE | | | WHERE THE PROPOSED WINDOW IS LOCATED. SEE FBCR302.1 AND | | | TABLE R302.1 FOR REQUIRED FIRE SEPARATION DISTANCE FOR | | | OPENINGS. | | | | | | 2) THE OCCUPANCY, TYPE OF CONSTRUCTION AND LEVEL OF | | | ALTERATION ON SHEET A-1 ARE INCORRECT. THIS IS A SINGLE | | | FAMILY RESIDENCE WHICH IS AN R-3 OCCUPANCY (FBC SECTION | | | 310.1), THE TYPE OF CONSTRUCTION IS VB (FBC SECTION | | | 602) AND IT IS A LEVEL 2 ALTERATION PER FBC EXISTING | | | BUILDING SECTION 404. PLEASE CORRECT. | | | | | | 3) SPECIFY THE WINDSPEED AND EXPOSURE CATEGORY FOR THIS | | | PROJECT ON THE PLANS. THE WINDSPEED IS 170 MPH VULT / | | | 132 VASD AND THE EXPOSURE CATEGORY IS C. FBC R301.2.1.1 | | | AND R301.2.1.4.3 | | | | | | 4) SHOW COMPLIANCE WITH FBC ENERGY SECTION 402 BY | | | SUBMITTING THE REQUIRED ENERGY COMPLIANCE FORMS FOR THE | | | PROPOSED HABITABLE SPACE. | | | | | | 5) SHOW COMPLIANCE WITH FBC R314 .3.1 FOR REQUIRED | | | SMOKE ALARMS. | | | | | | 6) THE TITLE BLOCK ON THE PLAN SHEETS ARE MISSING SOME | | | OF THE MINIMUM INFORMATION REQUIRED BY FAC 61G1-16.004. | | | PLEASE INCLUDE THE LICENSE NUMBER OF THE ARCHITECTURAL | | | FIRM AND THE PRINTED NAME OF THE PERSON SEALING THE | | | PLANS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2013-05-20 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-05-20 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-05-20 |
Time |
14:36 |
Sent To |
|
|
| Notes |
| 2013-05-20 14:36:44 | 5-20-13 | | | APPROVED WITH EXCEPTION..... | | | SEE NOTES ON DRAWINGS. | | | VB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-06-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-06-24 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-06-14 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2013-06-14 09:42:05 | SENT TO R MCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-06-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-06-12 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-04-23 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2013-06-10 09:49:29 | 6/10 - CHANGED INCOMING DATE TO DATE OF INITIAL | | | APPLICATION AS APPLICANT WAS INFORMED THAT SUBMITTING | | | ADDITIONAL PLANS WOULD NOT AFFECT PLAN REVIEW (AND WAS | | | AT 30 DAYS AT TIME OF SUBMITTAL) | | | | | 2013-05-24 14:24:46 | ADD DRIVEWAY PLAN |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-06-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-06-12 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-04-23 |
Time |
07:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2013-06-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-06-24 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-06-24 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2013-06-24 16:15:06 | NO FEES WERE DUE |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2013-06-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-06-11 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-06-11 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2013-06-11 16:55:23 | IMPACT FEE REVIEW BY PALM BEACH COUNTY IS REQUIRED. ONE | | | SET OF THE APPROVED PLANS IS TO BE SIGNED OUT AND TAKEN | | | TO PALM BEACH COUNTY. THE STAMPED PLANS AND A COPY OF | | | THE IMPACT FEE RECEIPT ARE TO BE RETURNED TO THE CITY | | | BEFORE THE PERMIT IS ISSUED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2013-06-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-06-24 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-06-24 |
Time |
14:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2013-06-11 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-06-11 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-06-11 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2013-06-11 14:14:17 | PLANS DENIED | | | PROVIDE A PLAN SHOWING | | | DUCT AND GRILL SIZE AND CFM | | | PER SECTION 105 FBC 2010 | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2013-06-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-06-24 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-06-24 |
Time |
14:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2013-06-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-06-12 |
Time |
07:14 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-06-11 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2013-06-12 07:14:01 | 2010 FBC | | | | | | DENIED BY PLUMBING | | | | | | 1) AS A RESULT OF THIS PROJECT, THE WATER HEATER IS NOW | | | LOCATED IN HABITABLE SPACE AND IS REQUIRED TO BE | | | INSTALLED IN A METAL OR PLASTIC PAN WITH A DRAIN AND | | | TERMINATION POINT IN COMPLIANCE WITH FBCR P2801.5, | | | P2801.5.1 AND P2801.5.2. | | | | | | 2) THE PRESSURE RELIEF VALVE DISCHARGE SHALL COMPLY | | | WITH FBCR P2803.6.1. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2013-06-07 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2013-06-07 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2013-05-28 |
Time |
16:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2013-05-06 |
|
|
Cont ID |
|
| Sent By |
mdekle |
Date |
2013-05-06 |
Time |
|
Rev Time |
|
| Received By |
mdekle |
Date |
2013-05-06 |
Time |
|
Sent To |
|
|
| Notes |
| 2013-05-06 14:10:27 | ZONING REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. THE APPLICANT MUST PROVIDE A SURVEY OR SITE PLAN | | | DEPICTING THE DIMENSIONS OF THE EXISITING DRIVEWAY - IN | | | ACCORDANCE WITH SECTION 94-482 (B) CONFIGURATION, | | | REQUIRED OFF-STREET PARKING AREAS SHALL CONSIST OF A | | | PARKING BAY, STALL, DRIVEWAY, GARAGE, OR COMBINATION | | | THEREOF. THE SITE PLAN THAT WAS PROVIDED ON THE | | | PROPOSED PLANS IS NOT TO SCALE. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT THE CITY'S | | | ZONING ADMINISTRATOR, ANGELLA VANN 561-822-1441 AND/OR | | | CONSULT THE CITY?S ZONING AND LAND DEVELOPMENT | | | REGULATIONS ONLINE @WWW.MUNICODE.COM. | | | | | | | | | | | | | | | | | | | | | | | 2013-04-29 14:47:23 | 4/29/13 |
|
|