| Plan Review Stops For Permit 13040466 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2013-10-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-10-28 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-10-28 |
Time |
15:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2013-07-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-07-30 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-07-30 |
Time |
12:04 |
Sent To |
ENG |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-05-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-05-07 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-05-07 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2013-05-07 16:09:39 | BUILDING PLAN REVIEW | | | PERMIT: 13040466 | | | ADD: 1025 26TH ST | | | CONT: AHRENS COMPANIES | | | TEL: (561)863-9004 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: 5/30/2013 | | | ACTION: DENIED | | | | | | 1) SHEET 102.1 THE SITE PUSH WALL DETAILS DOES NOT | | | PROVIDE THE WIND DESIGN CRITERIA FOR THIS WIND ZONE AND | | | THAT THE FOUNDATION MEETS THE MOMENT OF OVERTURNINGFOR | | | THIS WIND SPEED. THE PRE ENGINEERED COMPONENT | | | MANUFACTURER WILL NEED THIS INFORMATION TO SIZE AND | | | DESIGN THE SHOP DRAWINGS FOR THIS WIND SPEED. | | | 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN- | | | CHAPTER 6 OF ASCE 7-10. | | | 1609.3 BASIC WIND SPEED FIGURE 1609.A-C | | | 1609.3 WIND SPEED CONVERSION | | | 1.1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN | | | ACCORDANCE WITH 1609.3.1 & ASCE 7-10 | | | | | | 1.2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10. | | | | | | 1.3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN | | | ACCORDANCE WITH 1609.4 & ASCE 7-10 | | | | | | 1.4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * | | | SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10. | | | | | | 1.5) COMPONENTS & CLADDING PRESSURES POSITVE & NEGATIVE | | | TABLE 1609.2(2) . | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2013-05-30 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-05-30 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-05-30 |
Time |
12:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2013-10-03 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2013-10-03 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2013-10-03 |
Time |
|
Sent To |
I |
|
| Notes |
| 2013-10-03 09:11:12 | ENGINEER OF RECORD MUST INSPECT AND CERTIFY TO CITY OF | | | WPB. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2013-09-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-09-23 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2013-09-23 08:44:21 | SEE PREVIOUS COMMENTS. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2013-07-30 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2013-07-30 |
Time |
|
Rev Time |
1.00 |
| Received By |
|
Date |
2013-07-30 |
Time |
|
Sent To |
|
|
| Notes |
| 2013-07-30 11:23:31 | PENDING STORM WATER APPROVAL THRU ENGINEERING |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2013-04-24 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-04-24 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-04-24 |
Time |
13:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-10-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-10-28 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-09-20 |
Time |
08:33 |
Sent To |
|
|
| Notes |
| 2013-10-23 18:27:51 | 10/23 TO JW DESK (NEW SHEET) | | | | | 2013-09-23 08:42:03 | SENT SUBMITTAL TO ENGINEERING BOX FOR M GONZALES TO PUT | | | WITH APPLICATION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-09-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-09-23 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-07-26 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2013-07-30 10:54:05 | RESUB ADDRESSING JIM'S DESK SENT TO JIM'S DESK FOR | | | REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-09-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-09-23 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-04-12 |
Time |
16:50 |
Sent To |
|
|
| Notes |
| 2013-04-12 16:52:28 | INCOMING SENT TO C-11BOX. JW |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2015-02-02 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-02-02 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-02-02 |
Time |
15:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2013-05-30 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2013-05-30 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2013-05-30 |
Time |
14:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2013-05-08 |
|
|
Cont ID |
|
| Sent By |
avann |
Date |
2013-05-08 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2013-05-08 |
Time |
12:59 |
Sent To |
|
|
| Notes |
| 2013-05-08 16:57:40 | 5/8/13- FAILED UNTIL THE CONTRACTOR SUBMITS AND PAYS | | | FOR A LANDSCAPE PERMIT. | | | | | | ANGELLA VANN, AICP | | | 561-822-1441 | | | [email protected] | | 2013-04-23 09:58:28 | 4/23/13 |
|
|