| Plan Review Stops For Permit 13040200 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2013-11-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-11-04 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-11-04 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2013-11-04 17:31:54 | SENT TO MCDOUGAL'S DESK FOR ELECTRICAL REVIEW. JG. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2013-09-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-09-19 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-09-19 |
Time |
07:34 |
Sent To |
|
|
| Notes |
| 2013-09-19 08:10:14 | ***NOTE: CHANGED BACK TO TWO FAMILY DWELLING. | | | | | | RESIDENTIAL (R3) ALTERATION, THIRD BUILDING REVIEW | | | CHECKLIST. | | | CODE: 2010 FBC. | | | | | | 1- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | | 101.4.3 OF 2010 FBC-ENERGY CONSERVATION. PLEASE MAKE | | | SURE FORM IS COMPLETELY FILLED AND CERTIFIED BY ALL | | | PARTIES AT THE BOTTOM OF FORM. (REPEAT COMMENT. THREE | | | TIMES. NOT ADDRESSED). | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2013-07-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-07-12 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-07-12 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2013-07-12 10:09:50 | NOTE: OWNER CHANGED BACK TO TWO FAMILY DWELLING. | | | | | | RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW COMMENTS. | | | CODE: 2010 FBC-RESIDENTIAL. | | | | | | 1- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | | 101.4.3 OF 2010 FBC-ENERGY CONSERVATION. PLEASE MAKE | | | SURE ALL THE INFORMATION IS COMPLETED ON THE FORM AND | | | IT'S SIGNED BY THE PREPARER AND OWNER/AGENT. (THIS WAS | | | REQUESTED ON THE A/C REVIEW. THERE IS NO INFORMATION | | | SUBMITTED FOR THE A/C). | | | | | | 2- CLARIFY IF DOING WORK ON THE SECOND FLOOR. SHEET 4 | | | OF 4 SAYS EXISTING SECOND FLOOR PLAN. SEC. 107.2.1 CITY | | | AMENDMENTS TO FBC. IF NO WORK, THEN NO NEED TO PROVIDE | | | FLOOR PLAN. | | | | | | 3- SHEET 1 OF 4: | | | A) CLARIFY FIRST NOTE UNDER GENERAL NOTES (NEW | | | CONSTRUCTION). WHAT IT MEANS BY "OR APPROVED WINDOWS". | | | ACCORDING TO THE SCOPE OF WORK ALL WINDOWS AND DOORS | | | ARE EXISTING. REVISE AS REQUIRED. | | | | | | B) CLARIFY WHAT KIND OF WASHER IS THE ONE SHOWN ON THE | | | UTILITY AREA. DISH-WASHER OR CLOTHES WASHER? (SHEET 2 | | | OF 4 SHOWS AN OUTSIDE CLOTHES WASHER. SEC. 107.2.1 CITY | | | AMENDMENTS TO FBC. | | | | | | 4- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR ONE | | | HOUR FLOOR ASSEMBLY SEPARATING THE TWO DWELLINGS. SEE | | | SEC. R302.3 OF 2010 FBC-RESIDENTIAL. | | | M E119 OR UL 263. | | | | | | 5- WINDOW ON BEDROOM #4 DOESN'T COMPLY WITH THE EGRESS | | | MIN. HEIGHT REQUIREMENTS OF SEC. R310.1.2 OF 2010 | | | FBC-RESIDENTIAL. REVISE AS REQUIRED. | | | | | | 6- PROVIDE PRODUCT APPROVAL FOR NEW WINDOW IN BEDROOM | | | #4 AS REQUIRED BY DCA RULE 9N-3. | | | | | | 7- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS. SEC. | | | 107.3.4.1 CITY AMENDMENTS TO FBC. | | | | | | ****NOTE: ALL THE APPLIANCES (WASHER, DRYER AND WATER | | | HEATERS) THAT ARE GOING TO BE INSTALLED OUTSIDE NEED TO | | | BE DESIGNED FOR OUTSIDE LOCATIONS. INSPECTOR WILL ASK | | | FOR MANUFACTURER SPECS AT TIME OF INSPECTION. PLEASE | | | MAKE SURE THIS INFORMATION IS AVAILABLE FOR THE | | | INSPECTOR. OTHERWISE INSPECTION WILL BE FAILED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-04-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-04-17 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-04-17 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2013-04-17 13:25:18 | ALTERATION/CHANGE OF OCCUPANCY BUILDING REVIEW | | | COMMENTS. | | | CODE: 2010-FBC. | | | | | | 1- THERE ARE TWO BUILDINGS IN THIS PROPERTY. CITY | | | RECORDS SHOWS DUPLEX ON EACH BUILDING FOR A TOTAL OF 4 | | | UNITS. PLANS SUBMITTED SEEM TO CHANGE NUMBER OF UNITS. | | | CLEARLY IDENTIFY HOW MANY UNITS ARE PROPOSED. SEC. | | | 107.2.1 CITY AMENDMENTS TO FBC. | | | AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | | COUNTY (2300 N. JOG RD) TO VERIFY IF IMPACT FEES ARE | | | DUE. BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID | | | RECEIPT IF FEES ARE DUE. | | | | | | 2- CHANGING USE FROM ONE AND TWO FAMILY (R3) TO | | | MULTIFAMILY (R2). PROVIDE COMPLETE PLANS AND | | | SPECIFICATIONS SHOWING COMPLIANCE WITH CHAPTER 9 | | | (CHANGE OF OCCUPANCY) OF THE 2010 FBC-EXISTING | | | BUILDING. NOTE; PLANS NEED TO BE REVISED FOR EVERYTHING | | | THAT APPLIES TO R2 OCCUPANCY. PROVIDE COMPLETE FLOOR | | | PLANS SHOWING ALL THE DWELLING UNITS. PROVIDE | | | SPECIFICATIONS AND DETAILS FOR APPROVED FIRE RATED | | | ASSEMBLIES FOR VERTICAL AND HORIZONTAL SEPARATION | | | BETWEEN EACH UNIT. PROVIDE SPECIFICATIONS FOR SMOKE | | | ALARMS (SEC. 907.2.11.2 FBC-2010). EXTERIOR WALLS | | | FIRE-RESISTANCE, OPENINGS PROTECTION (SPECIFY DISTANCE | | | BETWEEN BUILDINGS). EMERGENCY EGRESS REQUIREMENTS (SEC. | | | 1029 FBC-2010) (NOTE: ALL BEDROOM WINDOWS NEED TO | | | COMPLY). WIND LOADS AND HURRICANE OPENING PROTECTION. | | | STAIRS EGRESS REQUIREMENTS, SOUND INSULATION BETWEEN | | | UNITS (WALLS AND CEILINGS). PENETRATIONS IN FIRE RATED | | | WALLS OR FLOOR ASSEMBLIES. FIRE SEPARATION AND OPENING | | | PROTECTION FROM CARPORT (STORAGE USE S-2), OPENINGS NOT | | | ALLOWED FROM CARPORT TO SLEEPING ROOMS, ETC. | | | | | | 3- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. 913 | | | OF 2010 FBC-EXISTING BUILDING. | | | | | | 4- REVISE ALL THE DESIGN INFORMATION SHOWN ON DRAWING 1 | | | OF 3. | | | A) SPECIFY OCCUPANCY AND USE AS REQUIRED BY SEC. 401.3 | | | OF 2010 FBC-EXISTING BUILDING. | | | | | | B) REFER TO ASCE 7-10 NOT ASCE 7-05. | | | | | | C) ACCORDING TO SEC. 1609.4.3 THESE BUILDINGS ARE | | | LOCATED IN EXPOSURE "C" NOT "B". REVISE THE EXPOSURE AS | | | REQUIRED AND SPECIFY ALL THE DESIGN PRESSURES FOR | | | COMPONENTS AND CLADDING ACCORDINGLY (DOORS AND | | | WINDOWS). | | | | | | D) CLEARLY IDENTIFY ON FLOR PLAN: A) WHICH ARE THE | | | INTERIOR BEARING WALLS. B) WHICH WHICH ARE THE NEW | | | WALLS. SEC. 107.2.1 CITY AMENDMENTS TO FBC. | | | | | | E) SPECIFY THE SIZE OF ENTRY DOORS FOR EACH APARTMENT | | | TO VERIFY COMPLIANCE WITH THE EGRESS REQUIREMENTS. SEC. | | | 1008 OF 2010 FBC. | | | | | | F) SPECIFY SAFETY GLASS ON WINDOWS ON HAZARDOUS | | | LOCATIONS AS REQUIRED BY SEC. 2406.4 OF 2010 FBC. SEE | | | WINDOW ADJACENT TO KITCHEN DOOR ON APARTMENT "A" AND | | | BEDROOM 1-A. | | | | | | 5- VALUE DECLARED IN THE PERMIT APPLICATION IS TOO LOW. | | | SEC. 109.3 CITY AMENDMENTS TO FBC. UPDATE THE VALUE TO | | | INCLUDE ALL THE SCOPE OF WORK FOR ALL THE TRADES, ALL | | | LABOR AND MATERIALS, CONTRACTOR'S OVERHEAD AND PROFIT, | | | AND, DESIGN PROFESSIONAL FEES. | | | | | | 6- PROVIDE PRODUCT APPROVALS (2 COPIES) AS REQUIRED BY | | | DCA RULE 9N-3 FOR: | | | A) ALL DOORS AND WINDOWS THAT WILL NEED TO BE REPLACED | | | TO COMPLY WITH NEW EGRESS REQUIREMENTS. | | | | | | B) HURRICANE SHUTTERS IF WINDOWS AND DOORS PRODUCT | | | APPROVALS SUBMITTED DON'T HAVE IMPACT PROTECTION. AND, | | | PROVIDE A COMPLETE INSTALLATION SCHEDULE. | | | | | | C) WINDOW MULLIONS, IF USED. SEE PLANS. | | | | | | D) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON | | | PLANS/DETAILS. NOTE: PROVIDE ONLY THE PRODUCT APPROVAL | | | COVER PAGE AND PAGE SHOWING THE SPECIFIED CONNECTOR. | | | | | | 7- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL OF THE ABOVE PRODUCT | | | APPROVALS AS REQUIRED BY SEC. 107.3.4.1 OF CITY | | | AMENDMENTS TO FBC. | | | | | | 8- NEW CERTIFICATE OF OCCUPANCY WILL BE REQUIRED WHEN | | | CHANGING FROM R3 TO R2. SEC. 901.4 OF 2010 FBC-EXISTING | | | BUILDING. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2013-11-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-11-13 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-11-13 |
Time |
08:49 |
Sent To |
|
|
| Notes |
| 2013-11-13 11:23:45 | APPROVED WITH EXCEPTION. RED-LINED PLANS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2013-09-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-09-26 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-09-24 |
Time |
17:46 |
Sent To |
|
|
| Notes |
| 2013-09-25 08:03:49 | 2010 FBC / 2008 NEC | | | | | | DENIED BY ELECTRIC | | | | | | 1) SPECIFY ON THE PLANS WHETHER THE UNDER-GROUND | | | SERVICE LATERAL IS UTILITY (FLORIDA POWER & LIGHT) OR | | | CUSTOMER OWNED. IF IT IS CUSTOMER OWNED SPECIFY THE | | | SERVICE CONDUCTOR SIZES. NEC 230.31 | | | | | | 2) PROVIDE TOTAL SERVICE LOAD (HOUSE LOAD) | | | CALCULATIONS. NEC 220.84 (B) | | | | | | 3) SPECIFY THE SIZES OF ALL CONDUCTORS ON THE PLANS. | | | NEC 310.15 | | | | | | 4) SHOW THE LOCATION OF THE HOUSE PANEL "H" ON THE | | | PLANS. NEC ARTICLE 408 | | | | | | 5) SHOW LOCATION OF THE DISCONNECT/ OVER-CURRENT | | | PROTECTION FOR THE 50 AMP HOUSE PANEL "H" ON THE PLANS. | | | NEC 230.72, 230.91 & 240.21 | | | | | | 6) A 150 AMP DISCONNECT/ OVER-CURRENT PROTECTION IS | | | SHOWN FOR THE 100 AMP PANEL "A". COMPLY WITH NEC 408.36 | | | WHICH REQUIRES THE OVER-CURRENT PROTECTION RATING TO | | | NOT BE MORE THAN THE PANEL. PLEASE CORRECT. | | | | | | 7) SHOW THE REQUIRED DISCONNECT/ OVERCURRENT PROTECTION | | | FOR THE FEEDERS AND THE 50 AMP SUB-PANEL "A-1". NEC | | | 230.05, 240.4, 240.21 & 408.36 | | | | | | 8) THE TOTAL LOAD CALCULATIONS FOR PANEL "A" SHOWN ON | | | THE PLAN IS MORE THAN 100 AMPS RATING OF THE PANEL. NEC | | | 408.30 REQUIRES PANELBOARDS TO HAVE A RATING OF NOT | | | LESS THAN THE MINIMUM FEEDER CAPACITY REQUIRED FOR THE | | | CALCULATED LOAD. | | | | | | 9) THE PANEL SCHEDULE AND LOAD CALCULATIONS FOR PANEL | | | "A" NEED TO INCLUDE THE 50 AMPS FOR SUB-PANEL "A-1" | | | THAT IT FEEDS. NEC 408.30 & 408.36 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2013-07-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-07-16 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-07-16 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2013-07-16 13:40:33 | 2010 FBC / 2008 NEC | | | | | | DENIED BY ELECTRIC | | | | | | 1) THE PLANS SHOW TWO 150 AMP ELECTRICAL PANELS LOCATED | | | IN UNIT 'A' AND ONLY ONE PANEL SCHEDULE FOR UNIT 'A'. | | | PLEASE CLARIFY. CITY AMENDMENTS 107.2.1 | | | | | | 2) THE PLANS SHOW THAT THE AIR HANDLER FOR UNIT 'B' IS | | | LOCATED IN UNIT 'A'. THIS RESTRICTS ACCESS TO THE | | | EQUIPMENT BY THE OCCUPANTS OF THE UNIT THAT IT | | | SERVICES. NEC 240.24 (B) NOTE: THE DUCTWORK WILL | | | PENETRATE THE ONE HOUR FIRE RATE SEPARATION BETWEEN | | | UNITS 'A' AND 'B' REQUIRING FIRE DAMPERS ON THE DUCTS. | | | | | | 3) SHOW COMPLIANCE WITH NEC 250.94 FOR INTERSYSTEM | | | BONDING. | | | | | | 4) SHOW COMPLIANCE WITH NEC 210.12 (B) FOR ARC-FAULT | | | CIRCUIT INTERRUPTER PROTECTION REQUIRED IN OTHER ROOMS | | | AND AREAS IN ADDITION TO BEDROOMS. | | | | | | 5) SHOW COMPLIANCE WITH NEC 406.11 FOR TAMPER RESISTANT | | | RECEPTACLES. | | | | | | 6) SPECIFY THE LOCATION OF THE ELECTRICAL PANEL IN UNIT | | | 'B'. NEC 240.24 | | | | | | 7) PROVIDE AN ELECTRICAL PLAN FOR UNIT 'B' OR REVISE | | | THE SCOPE OF WORK ON SHEET 2 TO EXCLUDE UNIT 'B'. CITY | | | AMENDMENTS 107.2.1 | | | | | | 8) SHOW COMPLIANCE WITH FBC R314.3.1 FOR SMOKE ALARMS | | | IN UNIT 'B'. | | | | | | 9) A RECEPTACLE IS REQUIRED IN BEDROOMS # 1 AND # 4 | | | BETWEEN THE CLOSET DOOR AND THE BEDROOM DOOR PER NEC | | | 210.52 (A). | | | | | | 10) PANEL SCHEDULE FOR UNIT 'A' ONLY LISTS THE CIRCUITS | | | FOR TWO OF THE FOUR BEDROOMS. NEC 220.83 PLEASE | | | CORRECT. | | | | | | 11) NEC 210.11 (C) (1) REQUIRES A MINIMUM OF TWO 20 AMP | | | SMALL APPLIANCE BRANCH CIRCUITS IN EACH UNIT. | | | | | | 12) AFTER ADDING THE CIRCUITS LISTED IN REVIEW COMMENTS | | | 10 AND 11, PLEASE REVISE THE LOAD CALCULATIONS. NEC | | | 220.83 (B) | | | | | | 13) THE ELECTRICAL RISER PLAN SHOWS TWO SEPARATE METERS | | | WITH TWO SEPARATE SERVICE LATERALS FOR THIS BUILDING. | | | NEC 230.2 ALLOWS ONLY ONE SERVICE PER BUILDING. PLEASE | | | REVISE RISER PLAN TO SHOW A SINGLE SERVICE DROP OR | | | LATERAL SUPPLY TO A DUPLEX METER BASE. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2013-04-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-04-26 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-04-26 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2013-04-26 16:42:40 | PER OWNER THE BUILDING WILL REMAIN A TWO FAMILY | | | DWELLING AND NEW PLANS WILL BE SUBMITTED. NO ELECTRICAL | | | REVIEW WAS DONE AT THIS TIME. | | 2013-04-17 13:28:12 | SEE BUILDING COMMENTS. JG. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
N |
Date |
2013-06-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-06-25 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-06-25 |
Time |
13:47 |
Sent To |
|
|
| Notes |
| 2013-06-25 13:48:39 | OWNER CHANGED PLANS BACK TO ONE AND TWO FAMILY | | | DWELLING. NO FIRE REVIEW REQUIRED. JG. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2013-04-20 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-04-20 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-04-20 |
Time |
12:52 |
Sent To |
|
|
| Notes |
| 2013-04-20 13:24:08 | 724 BRADLEY STREET | | | PERMIT #13040200 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | *****CHANGE OF OCCUPANCY FROM 1-2 FAMILY DWELLING TO | | | APARTMENTS***** | | | | | | NOTE: ALL FIRE REVIEW COMMENTS REFERENCING NFPA 101 | | | REFER TO NFPA 101-THE LIFE SAFETY CODE (2009 EDITION | | | WITH FLORIDA AMENDMENTS.) | | | | | | DESIGN THE 2010 EDITION OF THE FLORIDA FIRE PREVENTION | | | CODE WHICH CONTAINS THE 2009 EDITION OF BOTH NFPA 1 AND | | | NFPA 101 WITH FLORIDA AMENDMENTS. | | | | | | DRAWING INDICATES THERE ARE STAIRS SERVING ADDITIONAL | | | APARTMENT(S) ABOVE. PROVIDE A COMPLETE LIFE SAFETY PLAN | | | INDICATING TOTAL NUMBER OF UNITS, EXIT DOORS, EGRESS | | | WINDOWS, TRAVEL DISTANCES, STAIRS, HANDRAIL DETAILS, | | | HORIZONTAL AND VERTICAL FIRE BARRIERS, ETC. | | | | | | PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS | | | SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE | | | TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL | | | DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET. | | | | | | PROVIDE CARBON MONOXIDE ALARMS AND HARD-WIRED | | | MULTI-STATION SMOKE ALARMS SHALL BE INSTALLED ON ALL | | | LEVELS OF THE DWELLING UNIT, INSIDE EACH BEDROOM AND | | | DIRECTLY OUTSIDE BEDROOM DOORS. | | | | | | ALL NEW APARTMENTS SHALL BE PROTECTED THROUGHOUT BY A | | | SUPERVISED FIRE SPRINKLER SYSTEM PER SECTION 30.3.5. | | | | | | PER FLORIDA ADMINISTRATIVE CODE SECTION 61G15-32.004, | | | FIRE PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE | | | POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF | | | APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT, | | | CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | | AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER | | | SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA) | | | AND ANY PERFORMANCE BASED INFORMATION SUCH AS | | | PRE-ENGINEERED SYSTEMS. | | | | | | WESLEY JOLIN | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 | | | | | 2013-04-17 13:25:51 | SEE BUILDING COMMENTS. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2013-11-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-11-13 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-10-25 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2013-10-30 15:34:15 | SENT TO JULIO'S DESK FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-09-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-09-25 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-08-13 |
Time |
09:13 |
Sent To |
|
|
| Notes |
| 2013-08-14 09:14:08 | SENT TO R14 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-07-22 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-07-22 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-06-25 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2013-06-25 13:57:15 | SENT TO R12 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-04-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-04-26 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-04-04 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2013-04-05 13:40:48 | SENT TO B20 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2013-07-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-07-12 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-07-12 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2013-07-12 13:38:44 | CHANGED BACK TO EXISTING USE: 2 UNITS PER BUILDING. SEE | | | PLANS. JG. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2013-04-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-04-17 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-04-17 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2013-04-17 13:17:26 | CITY RECORDS SHOWS DUPLEX ON EACH BUILDING FOR A TOTAL | | | OF 4 UNITS. PLANS SUBMITTED SEEM TO CHANGE OF UNITS. | | | AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | | COUNTY (2300 N. JOG RD) TO VERIFY IF IMPACT FEES ARE | | | DUE. BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID | | | RECEIPT IF FEES ARE DUE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2013-09-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-09-19 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-09-19 |
Time |
08:46 |
Sent To |
|
|
| Notes |
| 2013-09-19 08:48:52 | 1-PROVIDE COMPLETE INFORMATION FOR THE A/C. PROVIDE | | | DUCTWORK LAYOUT, EQUIPMENT SIZING CALCULATIONS, ETC. | | | UNDER A SEPARATE PERMIT. JG. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2013-07-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-07-15 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-07-15 |
Time |
16:16 |
Sent To |
|
|
| Notes |
| 2013-07-15 16:17:45 | RESIDENTIAL (R3) ALTERATION, MECHANICAL REVIEW | | | COMMENTS. | | | CODE: 2010 FBC-RESIDENTIAL. | | | | | | | | | 1- PROVIDE COMPLETE INFORMATION FOR THE A/C. PROVIDE | | | DUCTWORK LAYOUT, EQUIPMENT SIZING CALCULATIONS, ETC. | | | SEC. 103.2.2 AND SEC. 403.6 OF 2010 FBC-ENERGY | | | CONSERVATION. | | | | | | | | | IF YOU HAVE QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2013-04-12 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-04-12 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-04-12 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2013-04-17 13:27:00 | SEE BUILDING COMMENTS. JG. | | 2013-04-12 16:00:22 | ****CORRECTIONS**** | | | | | | 1. PROVIDE MECHANICAL PLANS. FBC 107 | | | | | | 2. PLAN NOT CLEAR, APPEARS TO BE TWO STORIES BUT NOT | | | LABELED AS SUCH. EQUIPMENT LOCATION NOT CLEAR. FBC 107 | | | | | | HAROLD MOSER, MECHANICAL PLANS EXAMINER | | | 561-805-6732 | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2013-09-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-09-10 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-09-10 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2013-09-19 08:50:58 | APPROVED BY LARRY ON 9/10/13. SEE PLANS. JG. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2013-07-22 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-07-22 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-07-22 |
Time |
12:27 |
Sent To |
|
|
| Notes |
| 2013-07-22 12:38:20 | FBC 2010 EXISTING BUILDING CODE | | | FBC 2010 PLUMBING REVIEW #2 | | | DENIED: | | | | | | NO CHANGE FOUND FROM REVIEW #1 | | | 1. SHEET 3: THE KITCHEN SINK IS NOT PERMITTED IN THE | | | BATHROOM WET VENT SYSTEM. | | | FBC 2010 RESIDENTIAL P3108.1 HORIZONTAL WET VENT | | | PERMITTED. | | | ANY COMBINATION OF FIXTURES WITHIN TWO BATHROOM GROUPS | | | LOCATED ON THE SAME FLOOR LEVEL IS PERMITTED TO BE | | | VENTED BY A HORIZONTAL WET VENT. THE WET VENT SHALL BE | | | CONSIDERED THE VENT FOR THE FIXTURES AND SHALL EXTEND | | | FROM THE CONNECTION OF THE DRY VENT ALONG THE DIRECTION | | | OF THE FLOW IN THE DRAIN PIPE TO THE MOST DOWNSTREAM | | | FIXTURE DRAIN CONNECTION TO THE HORIZONTAL BRANCH | | | DRAIN. EACH WET-VENTED FIXTURE DRAIN SHALL CONNECT | | | INDEPENDENTLY TO THE HORIZONTAL WET VENT. ONLY THE | | | FIXTURES WITHIN THE BATHROOM GROUPS SHALL CONNECT TO | | | THE WET-VENTED HORIZONTAL BRANCH DRAIN. ANY ADDITIONAL | | | FIXTURES SHALL DISCHARGE DOWNSTREAM OF THE HORIZONTAL | | | WET VENT. | | | | | | 2. THE DRAWING INDICATES THE SFBC CODE AND MIAMI DADE | | | ORD. THE BUILDING CODE AT THIS TIME IS THE 2010 FLORIDA | | | BUILDING CODE. | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805-6692 | | | EMAIL [email protected] | | | FAX # 805-6676 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2013-04-19 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-04-19 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-04-19 |
Time |
09:46 |
Sent To |
|
|
| Notes |
| 2013-04-19 10:04:20 | FBC 2010 EXISTING BUILDING CODE | | | FBC 2010 PLUMBING REVIEW #1 | | | DENIED: | | | | | | 1. SHEET 3: THE KITCHEN SINK IS NOT PERMITTED IN THE | | | BATHROOM WET VENT SYSTEM. | | | FBC 2010 P-909.1 HORIZONTAL WET VENT PERMITTED. | | | ANY COMBINATION OF FIXTURES WITHIN TWO BATHROOM GROUPS | | | LOCATED ON THE SAME FLOOR LEVEL IS PERMITTED TO BE | | | VENTED BY A HORIZONTAL WET VENT. THE WET VENT SHALL BE | | | CONSIDERED THE VENT FOR THE FIXTURES AND SHALL EXTEND | | | FROM THE CONNECTION OF THE DRY VENT ALONG THE DIRECTION | | | OF THE FLOW IN THE DRAIN PIPE TO THE MOST DOWNSTREAM | | | FIXTURE DRAIN CONNECTION TO THE HORIZONTAL BRANCH | | | DRAIN. EACH WET-VENTED FIXTURE DRAIN SHALL CONNECT | | | INDEPENDENTLY TO THE HORIZONTAL WET VENT. ONLY THE | | | FIXTURES WITHIN THE BATHROOM GROUPS SHALL CONNECT TO | | | THE WET-VENTED HORIZONTAL BRANCH DRAIN. ANY ADDITIONAL | | | FIXTURES SHALL DISCHARGE DOWNSTREAM OF THE HORIZONTAL | | | WET VENT. | | | | | | 2. THE DRAWING INDICATES THE SFBC CODE AND MIAMI /DADE | | | ORDS. THE BUILDING CODE AT THIS TIME IS THE 2010 | | | FLORIDA BUILDING CODE. | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805-6692 | | | EMAIL [email protected] | | | FAX # 805-6676 | | | | | 2013-04-17 13:27:52 | SEE BUILDING COMMENTS. JG. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2013-11-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-11-04 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-11-04 |
Time |
16:54 |
Sent To |
|
|
| Notes |
| 2013-11-04 16:55:17 | ROOFING NO INCLUDED IN THIS PERMIT. JG. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2013-07-11 |
|
|
Cont ID |
|
| Sent By |
avann |
Date |
2013-07-11 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2013-07-10 |
Time |
15:55 |
Sent To |
|
|
| Notes |
| 2013-07-10 15:06:40 | 7/10/13 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2013-07-11 |
|
|
Cont ID |
|
| Sent By |
mdekle |
Date |
2013-04-11 |
Time |
|
Rev Time |
|
| Received By |
dkittred |
Date |
2013-04-11 |
Time |
|
Sent To |
|
|
| Notes |
| 2013-04-11 09:11:21 | ZONING PLAN REVIEW | | | REVIEW STATUS: FAILED | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | 1. PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND | | | LAND DEVELOPMENT REGULATIONS (ZLDR): AS THE VALUE OF | | | THE PROPOSED WORK ($33,000.00) EXCEEDS 50% OF THE | | | STRUCTURE'S VALUE (LISTED AS "IMPROVEMENT VALUE" WITH | | | THE P.B.C. PROPERTY APPRAISER'S OFFICE), ($64,195.00) | | | LANDSCAPING SHALL BE IN COMPLIANCE WITH ALL APPLICABLE | | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. PLEASE | | | SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN SHOWING | | | COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF THE ZLDR. | | | 2. THE APPLICANT MUST CLARIFY THE NUMBER TO PROPOSED | | | UNITS, THE NUMBER OF EXISTING UNITS AND THE TOTAL | | | NUMBER OF UNITS FOR THE SITE. PLEASE BE ADVISED, THE | | | ZONING DISTRICT IS SINGLE FAMILY (SF7). THE PROPERY WAS | | | PREVIOULSY ISSUED RENTAL LICENSES FOR TWO BUILDINGS, | | | CONTAINING TWO UNITS PER BUILDING FOR A TOTAL OF FOUR | | | UNITS ON THE SUBJECT PROPERTY. | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | MURRIAH DEKLE, PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT - PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | PHONE: 561.822.1442 | | | EMAIL: [email protected] | | | WWW.WPB.ORG | | | | | | | | 2013-04-10 11:54:20 | 4/10/13 |
|
|