Plan Review Details - Permit 13040200
Plan Review Stops For Permit 13040200
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2013-11-04 Cont ID  
Sent By jgomez Date 2013-11-04 Time 17:31 Rev Time 0.00
Received By jgomez Date 2013-11-04 Time 16:03 Sent To  
Notes
2013-11-04 17:31:54SENT TO MCDOUGAL'S DESK FOR ELECTRICAL REVIEW. JG.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2013-09-19 Cont ID  
Sent By jgomez Date 2013-09-19 Time 08:10 Rev Time 0.00
Received By jgomez Date 2013-09-19 Time 07:34 Sent To  
Notes
2013-09-19 08:10:14***NOTE: CHANGED BACK TO TWO FAMILY DWELLING.
  
 RESIDENTIAL (R3) ALTERATION, THIRD BUILDING REVIEW
 CHECKLIST.
 CODE: 2010 FBC.
  
 1- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 101.4.3 OF 2010 FBC-ENERGY CONSERVATION. PLEASE MAKE
 SURE FORM IS COMPLETELY FILLED AND CERTIFIED BY ALL
 PARTIES AT THE BOTTOM OF FORM. (REPEAT COMMENT. THREE
 TIMES. NOT ADDRESSED).
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2013-07-15 Cont ID  
Sent By jgomez Date 2013-07-12 Time 13:39 Rev Time 0.00
Received By jgomez Date 2013-07-12 Time 09:41 Sent To  
Notes
2013-07-12 10:09:50NOTE: OWNER CHANGED BACK TO TWO FAMILY DWELLING.
  
 RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC-RESIDENTIAL.
  
 1- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 101.4.3 OF 2010 FBC-ENERGY CONSERVATION. PLEASE MAKE
 SURE ALL THE INFORMATION IS COMPLETED ON THE FORM AND
 IT'S SIGNED BY THE PREPARER AND OWNER/AGENT. (THIS WAS
 REQUESTED ON THE A/C REVIEW. THERE IS NO INFORMATION
 SUBMITTED FOR THE A/C).
  
 2- CLARIFY IF DOING WORK ON THE SECOND FLOOR. SHEET 4
 OF 4 SAYS EXISTING SECOND FLOOR PLAN. SEC. 107.2.1 CITY
 AMENDMENTS TO FBC. IF NO WORK, THEN NO NEED TO PROVIDE
 FLOOR PLAN.
  
 3- SHEET 1 OF 4:
 A) CLARIFY FIRST NOTE UNDER GENERAL NOTES (NEW
 CONSTRUCTION). WHAT IT MEANS BY "OR APPROVED WINDOWS".
 ACCORDING TO THE SCOPE OF WORK ALL WINDOWS AND DOORS
 ARE EXISTING. REVISE AS REQUIRED.
  
 B) CLARIFY WHAT KIND OF WASHER IS THE ONE SHOWN ON THE
 UTILITY AREA. DISH-WASHER OR CLOTHES WASHER? (SHEET 2
 OF 4 SHOWS AN OUTSIDE CLOTHES WASHER. SEC. 107.2.1 CITY
 AMENDMENTS TO FBC.
  
 4- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR ONE
 HOUR FLOOR ASSEMBLY SEPARATING THE TWO DWELLINGS. SEE
 SEC. R302.3 OF 2010 FBC-RESIDENTIAL.
 M E119 OR UL 263.
  
 5- WINDOW ON BEDROOM #4 DOESN'T COMPLY WITH THE EGRESS
 MIN. HEIGHT REQUIREMENTS OF SEC. R310.1.2 OF 2010
 FBC-RESIDENTIAL. REVISE AS REQUIRED.
  
 6- PROVIDE PRODUCT APPROVAL FOR NEW WINDOW IN BEDROOM
 #4 AS REQUIRED BY DCA RULE 9N-3.
  
 7- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS. SEC.
 107.3.4.1 CITY AMENDMENTS TO FBC.
  
 ****NOTE: ALL THE APPLIANCES (WASHER, DRYER AND WATER
 HEATERS) THAT ARE GOING TO BE INSTALLED OUTSIDE NEED TO
 BE DESIGNED FOR OUTSIDE LOCATIONS. INSPECTOR WILL ASK
 FOR MANUFACTURER SPECS AT TIME OF INSPECTION. PLEASE
 MAKE SURE THIS INFORMATION IS AVAILABLE FOR THE
 INSPECTOR. OTHERWISE INSPECTION WILL BE FAILED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-04-17 Cont ID  
Sent By jgomez Date 2013-04-17 Time 13:19 Rev Time 0.00
Received By jgomez Date 2013-04-17 Time 13:03 Sent To  
Notes
2013-04-17 13:25:18ALTERATION/CHANGE OF OCCUPANCY BUILDING REVIEW
 COMMENTS.
 CODE: 2010-FBC.
  
 1- THERE ARE TWO BUILDINGS IN THIS PROPERTY. CITY
 RECORDS SHOWS DUPLEX ON EACH BUILDING FOR A TOTAL OF 4
 UNITS. PLANS SUBMITTED SEEM TO CHANGE NUMBER OF UNITS.
 CLEARLY IDENTIFY HOW MANY UNITS ARE PROPOSED. SEC.
 107.2.1 CITY AMENDMENTS TO FBC.
 AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD) TO VERIFY IF IMPACT FEES ARE
 DUE. BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE.
  
 2- CHANGING USE FROM ONE AND TWO FAMILY (R3) TO
 MULTIFAMILY (R2). PROVIDE COMPLETE PLANS AND
 SPECIFICATIONS SHOWING COMPLIANCE WITH CHAPTER 9
 (CHANGE OF OCCUPANCY) OF THE 2010 FBC-EXISTING
 BUILDING. NOTE; PLANS NEED TO BE REVISED FOR EVERYTHING
 THAT APPLIES TO R2 OCCUPANCY. PROVIDE COMPLETE FLOOR
 PLANS SHOWING ALL THE DWELLING UNITS. PROVIDE
 SPECIFICATIONS AND DETAILS FOR APPROVED FIRE RATED
 ASSEMBLIES FOR VERTICAL AND HORIZONTAL SEPARATION
 BETWEEN EACH UNIT. PROVIDE SPECIFICATIONS FOR SMOKE
 ALARMS (SEC. 907.2.11.2 FBC-2010). EXTERIOR WALLS
 FIRE-RESISTANCE, OPENINGS PROTECTION (SPECIFY DISTANCE
 BETWEEN BUILDINGS). EMERGENCY EGRESS REQUIREMENTS (SEC.
 1029 FBC-2010) (NOTE: ALL BEDROOM WINDOWS NEED TO
 COMPLY). WIND LOADS AND HURRICANE OPENING PROTECTION.
 STAIRS EGRESS REQUIREMENTS, SOUND INSULATION BETWEEN
 UNITS (WALLS AND CEILINGS). PENETRATIONS IN FIRE RATED
 WALLS OR FLOOR ASSEMBLIES. FIRE SEPARATION AND OPENING
 PROTECTION FROM CARPORT (STORAGE USE S-2), OPENINGS NOT
 ALLOWED FROM CARPORT TO SLEEPING ROOMS, ETC.
  
 3- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. 913
 OF 2010 FBC-EXISTING BUILDING.
  
 4- REVISE ALL THE DESIGN INFORMATION SHOWN ON DRAWING 1
 OF 3.
 A) SPECIFY OCCUPANCY AND USE AS REQUIRED BY SEC. 401.3
 OF 2010 FBC-EXISTING BUILDING.
  
 B) REFER TO ASCE 7-10 NOT ASCE 7-05.
  
 C) ACCORDING TO SEC. 1609.4.3 THESE BUILDINGS ARE
 LOCATED IN EXPOSURE "C" NOT "B". REVISE THE EXPOSURE AS
 REQUIRED AND SPECIFY ALL THE DESIGN PRESSURES FOR
 COMPONENTS AND CLADDING ACCORDINGLY (DOORS AND
 WINDOWS).
  
 D) CLEARLY IDENTIFY ON FLOR PLAN: A) WHICH ARE THE
 INTERIOR BEARING WALLS. B) WHICH WHICH ARE THE NEW
 WALLS. SEC. 107.2.1 CITY AMENDMENTS TO FBC.
  
 E) SPECIFY THE SIZE OF ENTRY DOORS FOR EACH APARTMENT
 TO VERIFY COMPLIANCE WITH THE EGRESS REQUIREMENTS. SEC.
 1008 OF 2010 FBC.
  
 F) SPECIFY SAFETY GLASS ON WINDOWS ON HAZARDOUS
 LOCATIONS AS REQUIRED BY SEC. 2406.4 OF 2010 FBC. SEE
 WINDOW ADJACENT TO KITCHEN DOOR ON APARTMENT "A" AND
 BEDROOM 1-A.
  
 5- VALUE DECLARED IN THE PERMIT APPLICATION IS TOO LOW.
 SEC. 109.3 CITY AMENDMENTS TO FBC. UPDATE THE VALUE TO
 INCLUDE ALL THE SCOPE OF WORK FOR ALL THE TRADES, ALL
 LABOR AND MATERIALS, CONTRACTOR'S OVERHEAD AND PROFIT,
 AND, DESIGN PROFESSIONAL FEES.
  
 6- PROVIDE PRODUCT APPROVALS (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) ALL DOORS AND WINDOWS THAT WILL NEED TO BE REPLACED
 TO COMPLY WITH NEW EGRESS REQUIREMENTS.
  
 B) HURRICANE SHUTTERS IF WINDOWS AND DOORS PRODUCT
 APPROVALS SUBMITTED DON'T HAVE IMPACT PROTECTION. AND,
 PROVIDE A COMPLETE INSTALLATION SCHEDULE.
  
 C) WINDOW MULLIONS, IF USED. SEE PLANS.
  
 D) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON
 PLANS/DETAILS. NOTE: PROVIDE ONLY THE PRODUCT APPROVAL
 COVER PAGE AND PAGE SHOWING THE SPECIFIED CONNECTOR.
  
 7- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL OF THE ABOVE PRODUCT
 APPROVALS AS REQUIRED BY SEC. 107.3.4.1 OF CITY
 AMENDMENTS TO FBC.
  
 8- NEW CERTIFICATE OF OCCUPANCY WILL BE REQUIRED WHEN
 CHANGING FROM R3 TO R2. SEC. 901.4 OF 2010 FBC-EXISTING
 BUILDING.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2013-11-13 Cont ID  
Sent By rmcdouga Date 2013-11-13 Time 11:23 Rev Time 0.00
Received By rmcdouga Date 2013-11-13 Time 08:49 Sent To  
Notes
2013-11-13 11:23:45APPROVED WITH EXCEPTION. RED-LINED PLANS.

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2013-09-26 Cont ID  
Sent By rmcdouga Date 2013-09-26 Time 09:39 Rev Time 0.00
Received By rmcdouga Date 2013-09-24 Time 17:46 Sent To  
Notes
2013-09-25 08:03:492010 FBC / 2008 NEC
  
 DENIED BY ELECTRIC
  
 1) SPECIFY ON THE PLANS WHETHER THE UNDER-GROUND
 SERVICE LATERAL IS UTILITY (FLORIDA POWER & LIGHT) OR
 CUSTOMER OWNED. IF IT IS CUSTOMER OWNED SPECIFY THE
 SERVICE CONDUCTOR SIZES. NEC 230.31
  
 2) PROVIDE TOTAL SERVICE LOAD (HOUSE LOAD)
 CALCULATIONS. NEC 220.84 (B)
  
 3) SPECIFY THE SIZES OF ALL CONDUCTORS ON THE PLANS.
 NEC 310.15
  
 4) SHOW THE LOCATION OF THE HOUSE PANEL "H" ON THE
 PLANS. NEC ARTICLE 408
  
 5) SHOW LOCATION OF THE DISCONNECT/ OVER-CURRENT
 PROTECTION FOR THE 50 AMP HOUSE PANEL "H" ON THE PLANS.
 NEC 230.72, 230.91 & 240.21
  
 6) A 150 AMP DISCONNECT/ OVER-CURRENT PROTECTION IS
 SHOWN FOR THE 100 AMP PANEL "A". COMPLY WITH NEC 408.36
 WHICH REQUIRES THE OVER-CURRENT PROTECTION RATING TO
 NOT BE MORE THAN THE PANEL. PLEASE CORRECT.
  
 7) SHOW THE REQUIRED DISCONNECT/ OVERCURRENT PROTECTION
 FOR THE FEEDERS AND THE 50 AMP SUB-PANEL "A-1". NEC
 230.05, 240.4, 240.21 & 408.36
  
 8) THE TOTAL LOAD CALCULATIONS FOR PANEL "A" SHOWN ON
 THE PLAN IS MORE THAN 100 AMPS RATING OF THE PANEL. NEC
 408.30 REQUIRES PANELBOARDS TO HAVE A RATING OF NOT
 LESS THAN THE MINIMUM FEEDER CAPACITY REQUIRED FOR THE
 CALCULATED LOAD.
  
 9) THE PANEL SCHEDULE AND LOAD CALCULATIONS FOR PANEL
 "A" NEED TO INCLUDE THE 50 AMPS FOR SUB-PANEL "A-1"
 THAT IT FEEDS. NEC 408.30 & 408.36
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2013-07-16 Cont ID  
Sent By rmcdouga Date 2013-07-16 Time 11:24 Rev Time 0.00
Received By rmcdouga Date 2013-07-16 Time 11:24 Sent To  
Notes
2013-07-16 13:40:332010 FBC / 2008 NEC
  
 DENIED BY ELECTRIC
  
 1) THE PLANS SHOW TWO 150 AMP ELECTRICAL PANELS LOCATED
 IN UNIT 'A' AND ONLY ONE PANEL SCHEDULE FOR UNIT 'A'.
 PLEASE CLARIFY. CITY AMENDMENTS 107.2.1
  
 2) THE PLANS SHOW THAT THE AIR HANDLER FOR UNIT 'B' IS
 LOCATED IN UNIT 'A'. THIS RESTRICTS ACCESS TO THE
 EQUIPMENT BY THE OCCUPANTS OF THE UNIT THAT IT
 SERVICES. NEC 240.24 (B) NOTE: THE DUCTWORK WILL
 PENETRATE THE ONE HOUR FIRE RATE SEPARATION BETWEEN
 UNITS 'A' AND 'B' REQUIRING FIRE DAMPERS ON THE DUCTS.
  
 3) SHOW COMPLIANCE WITH NEC 250.94 FOR INTERSYSTEM
 BONDING.
  
 4) SHOW COMPLIANCE WITH NEC 210.12 (B) FOR ARC-FAULT
 CIRCUIT INTERRUPTER PROTECTION REQUIRED IN OTHER ROOMS
 AND AREAS IN ADDITION TO BEDROOMS.
  
 5) SHOW COMPLIANCE WITH NEC 406.11 FOR TAMPER RESISTANT
 RECEPTACLES.
  
 6) SPECIFY THE LOCATION OF THE ELECTRICAL PANEL IN UNIT
 'B'. NEC 240.24
  
 7) PROVIDE AN ELECTRICAL PLAN FOR UNIT 'B' OR REVISE
 THE SCOPE OF WORK ON SHEET 2 TO EXCLUDE UNIT 'B'. CITY
 AMENDMENTS 107.2.1
  
 8) SHOW COMPLIANCE WITH FBC R314.3.1 FOR SMOKE ALARMS
 IN UNIT 'B'.
  
 9) A RECEPTACLE IS REQUIRED IN BEDROOMS # 1 AND # 4
 BETWEEN THE CLOSET DOOR AND THE BEDROOM DOOR PER NEC
 210.52 (A).
  
 10) PANEL SCHEDULE FOR UNIT 'A' ONLY LISTS THE CIRCUITS
 FOR TWO OF THE FOUR BEDROOMS. NEC 220.83 PLEASE
 CORRECT.
  
 11) NEC 210.11 (C) (1) REQUIRES A MINIMUM OF TWO 20 AMP
 SMALL APPLIANCE BRANCH CIRCUITS IN EACH UNIT.
  
 12) AFTER ADDING THE CIRCUITS LISTED IN REVIEW COMMENTS
 10 AND 11, PLEASE REVISE THE LOAD CALCULATIONS. NEC
 220.83 (B)
  
 13) THE ELECTRICAL RISER PLAN SHOWS TWO SEPARATE METERS
 WITH TWO SEPARATE SERVICE LATERALS FOR THIS BUILDING.
 NEC 230.2 ALLOWS ONLY ONE SERVICE PER BUILDING. PLEASE
 REVISE RISER PLAN TO SHOW A SINGLE SERVICE DROP OR
 LATERAL SUPPLY TO A DUPLEX METER BASE.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2013-04-26 Cont ID  
Sent By rmcdouga Date 2013-04-26 Time 16:39 Rev Time 0.00
Received By rmcdouga Date 2013-04-26 Time 16:39 Sent To  
Notes
2013-04-26 16:42:40PER OWNER THE BUILDING WILL REMAIN A TWO FAMILY
 DWELLING AND NEW PLANS WILL BE SUBMITTED. NO ELECTRICAL
 REVIEW WAS DONE AT THIS TIME.
2013-04-17 13:28:12SEE BUILDING COMMENTS. JG.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status N Date 2013-06-25 Cont ID  
Sent By jgomez Date 2013-06-25 Time 13:47 Rev Time 0.00
Received By jgomez Date 2013-06-25 Time 13:47 Sent To  
Notes
2013-06-25 13:48:39OWNER CHANGED PLANS BACK TO ONE AND TWO FAMILY
 DWELLING. NO FIRE REVIEW REQUIRED. JG.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2013-04-20 Cont ID  
Sent By wjolin Date 2013-04-20 Time 13:24 Rev Time 0.00
Received By wjolin Date 2013-04-20 Time 12:52 Sent To  
Notes
2013-04-20 13:24:08724 BRADLEY STREET
 PERMIT #13040200
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 *****CHANGE OF OCCUPANCY FROM 1-2 FAMILY DWELLING TO
 APARTMENTS*****
  
 NOTE: ALL FIRE REVIEW COMMENTS REFERENCING NFPA 101
 REFER TO NFPA 101-THE LIFE SAFETY CODE (2009 EDITION
 WITH FLORIDA AMENDMENTS.)
  
 DESIGN THE 2010 EDITION OF THE FLORIDA FIRE PREVENTION
 CODE WHICH CONTAINS THE 2009 EDITION OF BOTH NFPA 1 AND
 NFPA 101 WITH FLORIDA AMENDMENTS.
  
 DRAWING INDICATES THERE ARE STAIRS SERVING ADDITIONAL
 APARTMENT(S) ABOVE. PROVIDE A COMPLETE LIFE SAFETY PLAN
 INDICATING TOTAL NUMBER OF UNITS, EXIT DOORS, EGRESS
 WINDOWS, TRAVEL DISTANCES, STAIRS, HANDRAIL DETAILS,
 HORIZONTAL AND VERTICAL FIRE BARRIERS, ETC.
  
 PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS
 SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE
 TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL
 DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET.
  
 PROVIDE CARBON MONOXIDE ALARMS AND HARD-WIRED
 MULTI-STATION SMOKE ALARMS SHALL BE INSTALLED ON ALL
 LEVELS OF THE DWELLING UNIT, INSIDE EACH BEDROOM AND
 DIRECTLY OUTSIDE BEDROOM DOORS.
  
 ALL NEW APARTMENTS SHALL BE PROTECTED THROUGHOUT BY A
 SUPERVISED FIRE SPRINKLER SYSTEM PER SECTION 30.3.5.
  
 PER FLORIDA ADMINISTRATIVE CODE SECTION 61G15-32.004,
 FIRE PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE
 POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF
 APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT,
 CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR
 AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER
 SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA)
 AND ANY PERFORMANCE BASED INFORMATION SUCH AS
 PRE-ENGINEERED SYSTEMS.
  
 WESLEY JOLIN
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  
2013-04-17 13:25:51SEE BUILDING COMMENTS. JG.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2013-11-13 Cont ID  
Sent By rmcdouga Date 2013-11-13 Time 11:23 Rev Time 0.00
Received By rmcdouga Date 2013-10-25 Time 15:33 Sent To  
Notes
2013-10-30 15:34:15SENT TO JULIO'S DESK FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2013-09-25 Cont ID  
Sent By rmcdouga Date 2013-09-25 Time 11:13 Rev Time 0.00
Received By rmcdouga Date 2013-08-13 Time 09:13 Sent To  
Notes
2013-08-14 09:14:08SENT TO R14 SHELF FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-07-22 Cont ID  
Sent By lwagner Date 2013-07-22 Time 12:39 Rev Time 0.00
Received By lwagner Date 2013-06-25 Time 13:56 Sent To  
Notes
2013-06-25 13:57:15SENT TO R12 SHELF FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-04-26 Cont ID  
Sent By rmcdouga Date 2013-04-26 Time 16:42 Rev Time 0.00
Received By rmcdouga Date 2013-04-04 Time 13:39 Sent To  
Notes
2013-04-05 13:40:48SENT TO B20 SHELF FOR REVIEW. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2013-07-12 Cont ID  
Sent By jgomez Date 2013-07-12 Time 13:37 Rev Time 0.00
Received By jgomez Date 2013-07-12 Time 13:37 Sent To  
Notes
2013-07-12 13:38:44CHANGED BACK TO EXISTING USE: 2 UNITS PER BUILDING. SEE
 PLANS. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2013-04-17 Cont ID  
Sent By jgomez Date 2013-04-17 Time 13:15 Rev Time 0.00
Received By jgomez Date 2013-04-17 Time 13:15 Sent To  
Notes
2013-04-17 13:17:26CITY RECORDS SHOWS DUPLEX ON EACH BUILDING FOR A TOTAL
 OF 4 UNITS. PLANS SUBMITTED SEEM TO CHANGE OF UNITS.
 AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD) TO VERIFY IF IMPACT FEES ARE
 DUE. BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2013-09-23 Cont ID  
Sent By jgomez Date 2013-09-19 Time 08:46 Rev Time 0.00
Received By jgomez Date 2013-09-19 Time 08:46 Sent To  
Notes
2013-09-19 08:48:521-PROVIDE COMPLETE INFORMATION FOR THE A/C. PROVIDE
 DUCTWORK LAYOUT, EQUIPMENT SIZING CALCULATIONS, ETC.
 UNDER A SEPARATE PERMIT. JG.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2013-07-16 Cont ID  
Sent By jgomez Date 2013-07-15 Time 16:17 Rev Time 0.00
Received By jgomez Date 2013-07-15 Time 16:16 Sent To  
Notes
2013-07-15 16:17:45RESIDENTIAL (R3) ALTERATION, MECHANICAL REVIEW
 COMMENTS.
 CODE: 2010 FBC-RESIDENTIAL.
  
  
 1- PROVIDE COMPLETE INFORMATION FOR THE A/C. PROVIDE
 DUCTWORK LAYOUT, EQUIPMENT SIZING CALCULATIONS, ETC.
 SEC. 103.2.2 AND SEC. 403.6 OF 2010 FBC-ENERGY
 CONSERVATION.
  
  
 IF YOU HAVE QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2013-04-12 Cont ID  
Sent By hmoser Date 2013-04-12 Time 15:28 Rev Time 0.00
Received By hmoser Date 2013-04-12 Time 15:28 Sent To  
Notes
2013-04-17 13:27:00SEE BUILDING COMMENTS. JG.
2013-04-12 16:00:22****CORRECTIONS****
  
 1. PROVIDE MECHANICAL PLANS. FBC 107
  
 2. PLAN NOT CLEAR, APPEARS TO BE TWO STORIES BUT NOT
 LABELED AS SUCH. EQUIPMENT LOCATION NOT CLEAR. FBC 107
  
 HAROLD MOSER, MECHANICAL PLANS EXAMINER
 561-805-6732
  
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2013-09-23 Cont ID  
Sent By jgomez Date 2013-09-10 Time 08:50 Rev Time 0.00
Received By jgomez Date 2013-09-10 Time 08:50 Sent To  
Notes
2013-09-19 08:50:58APPROVED BY LARRY ON 9/10/13. SEE PLANS. JG.

Review Stop P PLUMBING
Rev No 2 Status F Date 2013-07-22 Cont ID  
Sent By lwagner Date 2013-07-22 Time 12:39 Rev Time 0.00
Received By lwagner Date 2013-07-22 Time 12:27 Sent To  
Notes
2013-07-22 12:38:20FBC 2010 EXISTING BUILDING CODE
 FBC 2010 PLUMBING REVIEW #2
 DENIED:
  
 NO CHANGE FOUND FROM REVIEW #1
 1. SHEET 3: THE KITCHEN SINK IS NOT PERMITTED IN THE
 BATHROOM WET VENT SYSTEM.
 FBC 2010 RESIDENTIAL P3108.1 HORIZONTAL WET VENT
 PERMITTED.
 ANY COMBINATION OF FIXTURES WITHIN TWO BATHROOM GROUPS
 LOCATED ON THE SAME FLOOR LEVEL IS PERMITTED TO BE
 VENTED BY A HORIZONTAL WET VENT. THE WET VENT SHALL BE
 CONSIDERED THE VENT FOR THE FIXTURES AND SHALL EXTEND
 FROM THE CONNECTION OF THE DRY VENT ALONG THE DIRECTION
 OF THE FLOW IN THE DRAIN PIPE TO THE MOST DOWNSTREAM
 FIXTURE DRAIN CONNECTION TO THE HORIZONTAL BRANCH
 DRAIN. EACH WET-VENTED FIXTURE DRAIN SHALL CONNECT
 INDEPENDENTLY TO THE HORIZONTAL WET VENT. ONLY THE
 FIXTURES WITHIN THE BATHROOM GROUPS SHALL CONNECT TO
 THE WET-VENTED HORIZONTAL BRANCH DRAIN. ANY ADDITIONAL
 FIXTURES SHALL DISCHARGE DOWNSTREAM OF THE HORIZONTAL
 WET VENT.
  
 2. THE DRAWING INDICATES THE SFBC CODE AND MIAMI DADE
 ORD. THE BUILDING CODE AT THIS TIME IS THE 2010 FLORIDA
 BUILDING CODE.
  
 REVIEW BY
 LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 PHONE # 805-6692
 EMAIL [email protected]
 FAX # 805-6676
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2013-04-19 Cont ID  
Sent By lwagner Date 2013-04-19 Time 10:12 Rev Time 0.00
Received By lwagner Date 2013-04-19 Time 09:46 Sent To  
Notes
2013-04-19 10:04:20FBC 2010 EXISTING BUILDING CODE
 FBC 2010 PLUMBING REVIEW #1
 DENIED:
  
 1. SHEET 3: THE KITCHEN SINK IS NOT PERMITTED IN THE
 BATHROOM WET VENT SYSTEM.
 FBC 2010 P-909.1 HORIZONTAL WET VENT PERMITTED.
 ANY COMBINATION OF FIXTURES WITHIN TWO BATHROOM GROUPS
 LOCATED ON THE SAME FLOOR LEVEL IS PERMITTED TO BE
 VENTED BY A HORIZONTAL WET VENT. THE WET VENT SHALL BE
 CONSIDERED THE VENT FOR THE FIXTURES AND SHALL EXTEND
 FROM THE CONNECTION OF THE DRY VENT ALONG THE DIRECTION
 OF THE FLOW IN THE DRAIN PIPE TO THE MOST DOWNSTREAM
 FIXTURE DRAIN CONNECTION TO THE HORIZONTAL BRANCH
 DRAIN. EACH WET-VENTED FIXTURE DRAIN SHALL CONNECT
 INDEPENDENTLY TO THE HORIZONTAL WET VENT. ONLY THE
 FIXTURES WITHIN THE BATHROOM GROUPS SHALL CONNECT TO
 THE WET-VENTED HORIZONTAL BRANCH DRAIN. ANY ADDITIONAL
 FIXTURES SHALL DISCHARGE DOWNSTREAM OF THE HORIZONTAL
 WET VENT.
  
 2. THE DRAWING INDICATES THE SFBC CODE AND MIAMI /DADE
 ORDS. THE BUILDING CODE AT THIS TIME IS THE 2010
 FLORIDA BUILDING CODE.
  
 REVIEW BY
 LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 PHONE # 805-6692
 EMAIL [email protected]
 FAX # 805-6676
  
2013-04-17 13:27:52SEE BUILDING COMMENTS. JG.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2013-11-04 Cont ID  
Sent By jgomez Date 2013-11-04 Time 16:54 Rev Time 0.00
Received By jgomez Date 2013-11-04 Time 16:54 Sent To  
Notes
2013-11-04 16:55:17ROOFING NO INCLUDED IN THIS PERMIT. JG.

Review Stop Z ZONING
Rev No 2 Status P Date 2013-07-11 Cont ID  
Sent By avann Date 2013-07-11 Time 10:32 Rev Time 0.00
Received By ajones Date 2013-07-10 Time 15:55 Sent To  
Notes
2013-07-10 15:06:407/10/13

Review Stop Z ZONING
Rev No 1 Status F Date 2013-07-11 Cont ID  
Sent By mdekle Date 2013-04-11 Time   Rev Time  
Received By dkittred Date 2013-04-11 Time   Sent To  
Notes
2013-04-11 09:11:21ZONING PLAN REVIEW
 REVIEW STATUS: FAILED
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 1. PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND
 LAND DEVELOPMENT REGULATIONS (ZLDR): AS THE VALUE OF
 THE PROPOSED WORK ($33,000.00) EXCEEDS 50% OF THE
 STRUCTURE'S VALUE (LISTED AS "IMPROVEMENT VALUE" WITH
 THE P.B.C. PROPERTY APPRAISER'S OFFICE), ($64,195.00)
 LANDSCAPING SHALL BE IN COMPLIANCE WITH ALL APPLICABLE
 REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. PLEASE
 SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN SHOWING
 COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF THE ZLDR.
 2. THE APPLICANT MUST CLARIFY THE NUMBER TO PROPOSED
 UNITS, THE NUMBER OF EXISTING UNITS AND THE TOTAL
 NUMBER OF UNITS FOR THE SITE. PLEASE BE ADVISED, THE
 ZONING DISTRICT IS SINGLE FAMILY (SF7). THE PROPERY WAS
 PREVIOULSY ISSUED RENTAL LICENSES FOR TWO BUILDINGS,
 CONTAINING TWO UNITS PER BUILDING FOR A TOTAL OF FOUR
 UNITS ON THE SUBJECT PROPERTY.
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 MURRIAH DEKLE, PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT - PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
 PHONE: 561.822.1442
 EMAIL: [email protected]
 WWW.WPB.ORG
  
  
2013-04-10 11:54:204/10/13


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved