Plan Review Details - Permit 13030854
Plan Review Stops For Permit 13030854
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2013-09-19 Cont ID  
Sent By jgomez Date 2013-09-19 Time 10:26 Rev Time 0.00
Received By jgomez Date 2013-09-19 Time 10:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2013-07-31 Cont ID  
Sent By jgomez Date 2013-07-30 Time 15:49 Rev Time 0.00
Received By jgomez Date 2013-07-30 Time 15:49 Sent To  
Notes
2013-07-30 16:24:38RESIDENTIAL (R3) ADDITION, BUILDING 1ST RE-SUBMITTAL
 COMMENTS.
 CODE: 2010 FBC.
  
 1- REVISE THE DESIGN PRESSURES SHOWN ON THE WINDOW
 SCHEDULE ON SHEET A-5. SOME WINDOWS ARE ON ZONE 4 AND
 SOME ARE ON ZONE 5. DESIGN PRESSURES SHOWN ARE FOR ZONE
 4 ONLY. SEE FIGURE R301.2(7) OF 2010 FBC-RESIDENTIAL
 AND REVISED DESIGN PRESSURES ON SHEET S-1.
  
 2- REVISE RAS 117 CALCULATIONS FOR BUILT UP ROOFING:
  
 A) FASTENER SPACING NEEDS TO BE ROUNDED DOWN AS
 REQUIRED BY SEC. 10.4.5 OF RAS 117.
  
 B) CLEARLY SPECIFY FASTENER SPACING AT THE LAP AND
 NUMBER OF ROWS AND FASTENER SPACING IN THE FIELD OF THE
 BASE SHEET. CALCULATIONS SUBMITTED ARE MISSING THIS
 INFORMATION. SEC. 107.2.1 CITY AMENDMENTS TO FBC.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-04-03 Cont ID  
Sent By jgomez Date 2013-04-03 Time 09:56 Rev Time 0.00
Received By jgomez Date 2013-04-03 Time 09:56 Sent To  
Notes
2013-04-03 10:02:47RESIDENTIAL (R3) ADDITION, BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- ACCORDING TO SEC. R301.2.1.4.3 OF 2010
 FBC-RESIDENTIAL THIS BUILDING IS LOCATED ON EXPOSURE
 "C" NOT 'B". REVISE THE STRUCTURAL NOTES AND ALL THE
 DESIGN PRESSURES ON SHEET A-1 TO CORRESPOND TO EXPOSURE
 "C". ALSO, REVISE THE DESIGN PRESSURES ON WINDOWS/DOORS
 SCHEDULES ON SHEET A-5 AS WELL.
  
 2- PROPER DESIGN OPERATION OF THE MECHANICAL AND
 ELECTRICAL SYSTEM CAN NOT BE ACHIEVED IF THE PLANS,
 MECHANICAL EQUIPMENT AND ELECTRICAL CALCULATIONS DON'T
 MATCH. FOR EXAMPLE; PLANS SHOW DRESSING ROOM, AN AREA
 THAT LOOKS LIKE A KITCHEN BUT THERE IS NO NAME, AND
 STORAGE. MECHANICAL EQUIPMENT AND ELECTRICAL
 CALCULATIONS DON'T CORRESPOND TO THE ROOMS AND USES
 SPECIFIED ON PLANS. REVISE AS REQUIRED TO MATCH. SEC.
 104.12 CITY AMENDMENTS TO FBC.
  
 *** CLARIFY: A) WHY DESIGNING A "DRESSING ROOM" WITH
 SOME MANY WINDOWS, SEPARATE ENTRY LEADING TO THE STREET
 AND HAVING TV AND PHONE OUTLETS. B) ROOM WITH LAYOUT OF
 A COMPLETE KITCHEN (SEE FLOOR PLANS AND INTERIOR
 ELEVATIONS), C) STORAGE ROOMS ADJACENT TO THE "KITCHEN"
 AREA AND WITH TV AND PHONE OUTLETS ALSO.
  
 3- PROVIDE PARTIAL LAYOUT OF EXISTING SPACES ADJACENT
 TO THE NEW DRESSING ROOM TO VERIFY THAT EGRESS AND
 VENTILATION ARE NOT AFFECTED BY BLOCKING THE WALL WITH
 THE NEW ADDITION. SEC. 107.2.1 CITY AMENDMENTS TO FBC.
  
 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR;
 A) FLAT ROOF AS SPECIFIED ON PLANS/DETAILS. AND PROVIDE
 RAS 117 CALCULATIONS FOR PERIMETER AND CORNER AREAS
 NAIL ENHANCING.
 ***NOTE: IF PRODUCT APPROVAL SUBMITTED REQUIRES SIGNED
 AND SEALED RAS 117 CALCULATIONS, THEN PROVIDE SIGNED
 AND SEALED CALCULATIONS.
  
 B) SHUTTERS FOR DOORS THAT HAVE NO IMPACT GLAZING (SEE
 NOA 09-0608.16 SUBMITTED). AND, PROVIDE COMPLETE
 SHUTTERS INSTALLATION SCHEDULE.
  
 C) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON
 PLANS/DETAILS. ***NOTE: PROVIDE ONLY THE PRODUCT
 APPROVAL COVER PAGE AND PAGE SHOWING THE SPECIFIED
 CONNECTOR.
  
 D) FIBERGLASS EXTERIOR DOOR. NOA 06-1215.03 SUBMITTED
 IS EXPIRED. NEED CURRENT ONE.
  
 E) PRECAST LINTELS AS SPECIFIED ON PLANS.
  
 5- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS. SEC.
 107.3.4.1 CITY AMENDMENTS TO FBC.
  
 6- REVISE THE ENERGY CALCULATIONS (NEED AN ACCURATELY
 COMPLETED FORM AS REQUIRED BY SEC. 103.2.1.1.2 OF 2010
 FBC-ENERGY CONSERVATION):
 A) REVISE ITEM #7. THE AREA AVERAGE OVERHANG DEPTH IS
 NOT 3.00FT. SEE PLANS AND REVISE AS REQUIRED.
  
 B) REVISE/CLARIFY IF INSTALLING NEW KITCHEN. REVISE
 "SPACES" SECTION ON SHEET 2 OF 5. SEE PLANS.
  
 C) REVISE ROOF SECTION ON PAGE 2 OF 5. THIS IS NO HIP
 ROOF AND THERE IS NOT CONCRETE TILE. SEE PLANS.
  
 D) REVISE DOORS ON PAGE 3 OF 5. THERE ARE NO WOOD
 DOORS. SEE PLANS AND PRODUCT APPROVALS.
  
 E) REVISE THE WINDOWS SECTION ON PAGE 3 OF 5: * REVISE
 THE WINDOW ORIENTATION TO MATCH PLANS. ** REVISE THE
 WINDOW AREAS TO MATCH PLANS. *** REVISE THE OVERHANG
 DEPTH AND SEPARATION OF EACH WINDOW TO MATCH
 PLANS/ELEVATIONS.
  
 F) OWNER/AGENT TO SIGN AND DATE BOTTOM OR FORM.
  
 G) COMPLETE ALL THE INFORMATION ON TOP OF FORM,
 INCLUDING THE BUILDER'S NAME.
  
 7- VALUE DECLARED IN THE PERMIT APPLICATION IS TOO LOW.
 SEC. 109.3 CITY AMENDMENTS TO FBC. VALUE TO INCLUDE ALL
 LABOR, MATERIALS, OVERHEAD AND PROFIT AND ALL THE
 DESIGN PROFESSIONAL FEES. VALUE WAS UPDATED, PERMIT FEE
 BALANCE IS $2444.70.
  
 8- SPECIFY ON PLANS (INCLUDING IN EXISTING BEDROOMS)
 CARBON MONOXIDE ALARMS AS REQUIRED BY SEC. R315 OF 2010
 FBC-RESIDENTIAL.
  
 9- PROVIDE ROOF SHEATHING SPECIFICATIONS. SEC.
 R803.2.3.1 OF 2010 FBC-RESIDENTIAL AND FIGURE
 R803.2.3.1.
  
 10- SPECIFY ROOF VENTILATION AS REQUIRED BY SEC. R806.
 SPECIFY SIZE LOCATION, ETC. INCLUDING THE RIDGE VENT.
 SEE RIDGE VENT PRODUCT APPROVAL SUBMITTED.
  
 11- SHEET A-2;
 A) CLARIFY IF INSTALLING NEW KITCHEN. THE LAYOUT IS THE
 SAME LAYOUT FOR A KITCHEN AND ENERGY CALCULATIONS CALL
 FOR ADDITION WITH KITCHEN. IDENTIFY THE SPACE WHERE THE
 NEW "KITCHEN" LAYOUT IS SHOWN. SEC. 107.2.1 CITY
 AMENDMENTS TO FBC.
  
 B) CLARIFY WHY THERE IS A NEW SEWER LINE GOING TO THE
 CLOSET IN THE ROOM ADJACENT TO THE "NEW STORAGE ROOM".
 SEC. 107.2.1 CITY AMENDMENTS.
  
 C) IDENTIFY ROOM WITH BAY WINDOWS. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 D) SPECIFY ATTIC ACCESS SIZE: SEC. R807.
  
 E) CLARIFY WHY INSTALLING TV, AND PHONE OUTLETS IN "NEW
 STORAGE ROOM". SEC. 107.2.1 CITY AMENDMENTS.
  
 12- SHEET A-4: CLARIFY WHY ELEVATION #4 SHOWS A "DRYER
 VENT HOOD". PLANS DON'T SHOW ANY DRYER. SEC. 107.2.1
 CITY AMENDMENTS.
  
 13- SHEET S-1; ENGINEER SHOWN ON-THE TITLE BLOCK AT
 BOTTOM OF SHEET NEEDS TO SIGN AND SEAL DRAWING AS
 REQUIRED BY SEC. 107.1 CITY AMENDMENTS.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2013-10-17 Cont ID  
Sent By dharvey Date 2013-10-17 Time 09:56 Rev Time 0.00
Received By dharvey Date 2013-10-17 Time 09:00 Sent To I
Notes
2013-10-17 09:59:45THIS FILE PROVED TO HAVE MET ALL OF THE PREVIOUSLY
 ADDRESSED ISSUED.
 I MADE A MENTION TO THE NUMBER OF BENDS INDICATED FOR
 THE FEEDER TO PANEL "A" IN PAGE A1 WHICH EXCEEDS THE
 MAXIMUM BENDS ALLOWED BY NEC 352.26
  
 SENT TO SH DESK BY MA
  
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2013-08-13 Cont ID  
Sent By rmcdouga Date 2013-08-13 Time 15:02 Rev Time 0.00
Received By rmcdouga Date 2013-08-13 Time 11:50 Sent To  
Notes
2013-08-13 17:05:112010 FBC / 2008 NEC
  
 DENIED BY ELECTRICAL
  
 1) SUBMIT VOLTAGE DROP CALCULATIONS FOR PANEL A FEEDERS
 TO SHOW EFFICIENCY OF OPERATION. CITY AMENDMENTS
 107.2.1.3
  
 2) NEC TABLE 310.15 (B) (6) CAN NOT BE USED TO SIZE THE
 CONDUCTORS TO THE TWO PANELBOARDS. THE EXCEPTION
 REQUIRES ONE PANELBOARD TO SUPPLY ALL LOADS ASSOCIATED
 WITH THE DWELLING UNIT. NEC TABLE 310.16 IS REQUIRED TO
 BE USED TO SIZE THE CURRENT CARRYING CONDUCTORS.
  
 3) SPECIFY THE LENGTH OF TAPS PER NEC 240.21.
  
 4) THE EQUIPMENT GROUNDING CONDUCTORS ARE REQUIRED TO
 BE SIZED IN ACCORDANCE WITH NEC 250.122.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2013-04-02 Cont ID  
Sent By rlecky Date 2013-04-02 Time 12:04 Rev Time 0.00
Received By rlecky Date 2013-04-02 Time 11:11 Sent To  
Notes
2013-04-02 12:05:12 
 13030854
 1004 BUNKER ROAD
 SFD ADDITION
  
 PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING
 ELECTRICAL REVIEW COMMENTS.
  
 VERIFY THE EXISTING HOME ALSO HAS SMOKE DETECTORS AND
 CARBON MONOXIDE DETECTORS. REMODELING OF AN EXISTING
 STRUCTURE IS REQUIRED TO INCLUDE INTERCONNECTED SMOKE
 ALARMS BOTH WITHIN AND OUTSIDE EACH SLEEPING AREA. IF
 THE RESIDENCE HAS GAS APPLIANCES, AN ATTACHED GARAGE OR
 A FIRE PLACE A CARBON MONOXIDE DETECTOR IS REQUIRED
 WITHIN TEN FEET OF EACH ROOM USED FOR SLEEPING. 2010
 FBC R314, 315
  
 SHOW THE LOCATION OF THE ELECTRICAL SERVICE AND
 EXISTING PANEL WITH MAIN DISCONNECTS. SHOW THE EXISTING
 AND NEW FEEDERS. VERIFY THAT ALL SERVICE DISCONNECTS
 ARE GROUPED IN ONE LOCATION. NEC 215.5, 230.2
  
 AN INTERSYSTEM BONDING STRIP IS REQUIRED AT THE MAIN
 SERVICE GROUND. NEC 250.94
  
 THE BATHROOM REQUIRES A DEDICATED 20 AMP BRANCH
 CIRCUIT. NEC 210.11 (C) (3)
  
 ROBERT LECKY
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6718
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2013-10-17 Cont ID  
Sent By shill Date 2013-10-17 Time 10:09 Rev Time 0.00
Received By shill Date 2013-08-28 Time 12:05 Sent To  
Notes
2013-08-28 16:55:38SENT TO R30 SHELF FOR REVIEW. JG.
2013-08-28 12:06:06INCOMING SENT TO JULIO'S DESK. JW

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-08-13 Cont ID  
Sent By rmcdouga Date 2013-08-13 Time 15:03 Rev Time 0.00
Received By rmcdouga Date 2013-07-12 Time 09:47 Sent To  
Notes
2013-07-15 09:50:47R25

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-04-11 Cont ID  
Sent By mdekle Date 2013-04-11 Time   Rev Time 0.00
Received By mdekle Date 2013-03-29 Time 09:10 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status P Date 2013-04-02 Cont ID  
Sent By jgomez Date 2013-04-02 Time 15:37 Rev Time 0.00
Received By jgomez Date 2013-04-02 Time 15:37 Sent To  
Notes
2013-04-02 15:38:15NO FEES. MU-2013-4811. JG.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2013-09-19 Cont ID  
Sent By jgomez Date 2013-09-19 Time 11:42 Rev Time 0.00
Received By jgomez Date 2013-09-19 Time 11:41 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2013-07-31 Cont ID  
Sent By jgomez Date 2013-07-31 Time 14:28 Rev Time 0.00
Received By jgomez Date 2013-07-31 Time 14:28 Sent To  
Notes
2013-07-31 15:01:05RESIDENTIAL (R3) ADDITION, RE-SUBMITTAL MECHANICAL
 REVIEW COMMENTS.
 CODE: 2010 FBC.
  
  
 1- PERSON RESPONSIBLE FOR THE DESIGN OF THE A/C PLAN
 NEEDS TO PROVIDE HIS NAME AND SIGNATURE AS REQUIRED BY
 SEC. 107.2.1 CITY AMENDMENTS TO FBC.
  
 2- DRAWINGS SUBMITTED HAVE A COPYRIGHT NOTE AT THE
 BOTTOM OF THE PAGE FROM AN ARCHITECT. ARCHITECT'S PLANS
 NEED TO BE SIGNED AND SEALED AS REQUIRED BY CHAPTER 481
 FLORIDA STATUTE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2013-04-09 Cont ID  
Sent By jgomez Date 2013-04-08 Time 16:13 Rev Time 0.00
Received By jgomez Date 2013-04-08 Time 14:59 Sent To  
Notes
2013-04-09 11:44:35RESIDENTIAL (R3) ADDITION MECHANICAL REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- INFORMATION SHOWN ON ENERGY CALCULATIONS AND
 RESIDENTIAL EQUIPMENT CALCULATIONS DON'T MATCH. CHECK
 THE TOTAL COOLING AND HEATING LOADS. SEC. 107.2.1 CITY
 AMENDMENTS TO FBC.
  
 2- EQUIPMENT SIZING CALCULATIONS TAKES INTO
 CONSIDERATION A KITCHEN. ACCORDING TO ARCHITECT'S PLANS
 SUBMITTED THERE IS NOT KITCHEN. REVISE AS REQUIRED.
 SEC. 107.2.1 CITY AMENDMENTS TO FBC.
  
 3- CFM'S SHOWN ON THE EQUIPMENT SIZING CALCULATIONS
 DON'T MATCH A/C PLAN. REVISE AS REQUIRED. SEC. 107.2.1
 CITY AMENDMENTS.
  
 4- EQUIPMENT MODELS SHOWN ON THE CERTIFICATE OF PRODUCT
 RATINGS DON'T MATCH EQUIPMENT SHOWN ON THE A/C PLAN.
 REVISE AS REQUIRED. SEC. 107.2.1 CITY AMENDMENTS.
  
 5- A/C PLAN NEEDS TO BE SIGNED AND SEALED BY THE
 ARCHITECT SHOWN ON THE TITLE BLOCK. SEC. 107.1 CITY
 AMENDMENTS.
  
 6- WHERE IS THE NATURAL GAS FURNACE SHOWN ON THE LAST
 PAGE OF EQUIPMENT SIZING CALCULATIONS?. SEC. 107.2.1
 CITY AMENDMENTS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop P PLUMBING
Rev No 3 Status P Date 2013-09-19 Cont ID  
Sent By jgomez Date 2013-09-19 Time 13:08 Rev Time 0.00
Received By jgomez Date 2013-09-19 Time 13:08 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2013-07-31 Cont ID  
Sent By jgomez Date 2013-07-31 Time 15:02 Rev Time 0.00
Received By jgomez Date 2013-07-31 Time 15:02 Sent To  
Notes
2013-07-31 15:43:22RESIDENTIAL (R3) ADDITION, RE-SUBMITTAL PLUMBING REVIEW
 COMMENTS.
 CODE: 2010 FBC.
  
  
 1- WASHER DRAIN IS CONNECTING TO THE BATHROOM GROUP
 WET-VENT. ONLY THE FIXTURES WITHIN THE BATHROOM GROUP
 SHALL CONNECT TO THE WET-VENTED HORIZONTAL BRANCH
 DRAIN. REVISE PLUMBING RISER DIAGRAM AS REQUIRED. SEC.
 P3108.1 OF 2010 FBC-RESIDENTIAL.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop P PLUMBING
Rev No 1 Status F Date 2013-04-08 Cont ID  
Sent By jgomez Date 2013-04-08 Time 16:38 Rev Time 0.00
Received By jgomez Date 2013-04-08 Time 16:38 Sent To  
Notes
2013-04-08 16:57:40RESIDENTIAL (R3) ADDITION PLUMBING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- PLUMBING RISER DIAGRAM DOESN'T MATCH PLANS. FLOOR
 PLAN DOESN'T SHOW ANY WASHER MACHINE.
  
 2- REVISE PLUMBING RISER DIAGRAM. ONLY THE FIXTURES
 WITHIN THE BATHROOM GROUP SHALL CONNECT TO THE
 WET-VENTED HORIZONTAL BRANCH DRAIN. REVISE PLUMBING
 RISER DIAGRAM AS REQUIRED. SEC. P3108.1 OF 2010
 FBC-RESIDENTIAL.
  
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop Z ZONING
Rev No 2 Status P Date 2013-07-17 Cont ID  
Sent By dkittenr Date 2013-07-17 Time 12:55 Rev Time 0.00
Received By dkittred Date 2013-07-16 Time 14:52 Sent To  
Notes
2013-09-19 11:26:55PLANNING & ZONING - 9/19/2013
  
 PLANS REVISED DUE TO BUILDING COMMENTS. RESTAMPED NEW
 PLANS 9/19/13 WITH P&Z APPROVAL. DK
2013-07-17 13:12:10PLANNING & ZONING DIVISION
 GENERAL NOTES:
  
 PLAN DOES NOT INDICATE THE REMOVAL OF ANY TREES,
 HOWEVER, SHOULD TREE(S) NEED TO BE CUT DOWN OR
 RELOCATED FOR THE PROPOSED PROJECT, AN APPLICATION FOR
 TREE ALTERATION PERMIT WILL BE REQUIRED FROM THE
 PLANNING & ZONING DEPT. THE APPLICATION CAN BE FOUND ON
 THE CITY'S WEBSITE OR OBTAINED IN PERSON AT PLANNING &
 ZONING OFFICE IN CITY HALL.
  
 DANIELLE J. KITTREDGE, AICP
 SENIOR PLANNER
 PLANNING & ZONING DIVISION
 PHONE: (561) 822-1443
 EMAIL: [email protected]
2013-07-16 14:32:027/16/13

Review Stop Z ZONING
Rev No 1 Status F Date 2013-04-11 Cont ID  
Sent By mdekle Date 2013-04-11 Time   Rev Time  
Received By mdekle Date 2013-04-11 Time   Sent To  
Notes
2013-04-11 08:11:33ZONING PLAN REVIEW
 REVIEW STATUS: FAILED
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 1. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH
 INCLUDES THE PROPERTY?S ADDRESS AND LEGAL DESCRIPTION.
  
  
 2. PURSUANT TO SECTION SEC. 94-72 OF THE ZONING AND
 LAND DEVELOPMENT REGULATIONS ("ZLDR"), THE MINIMUM
 SETBACKS FOR PRINCIPAL BUILDING IN A SINGLE-FAMILY LOW
 DENSITY ("SF7") RESIDENTIAL DISTRICT IS AS FOLLOWS:
  
 A. FRONT: 25 FEET;
 B. CORNER: 12.5 FEET;
 C. REAR: 15 FEET OR TEN PERCENT OF LOT DEPTH, WHICHEVER
 IS LESS;
 D. SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL
 THE PROPOSED FRONT BUILDING SETBACK DOES NOT MEET THE
 MINIMUM REQUIREMENTS. A APPLICANT MAY APPLY FOR A
 VARIANCE.
  
  
 3. PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND
 LAND DEVELOPMENT REGULATIONS (ZLDR): AS THE VALUE OF
 THE PROPOSED WORK EXCEEDS 50% OF THE STRUCTURE'S VALUE
 (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY
 APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE
 WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF
 THE ZLDR. PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE
 PLAN SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445
 OF THE ZLDR.
  
  
 4. PLEASE INDICATE SQUARE FOOTAGE OF ALL IMPERMEABLE
 SURFACES (EXISTING AND PROPOSED) LOCATED WITHIN THE
 FRONT YARD (FROM FRONT PROPERTY LINE TO THE FRONT
 BUILDING FACADE).THE MAXIMUM WIDTH FOR THE PROPOSED
 TYPE OF DRIVEWAY IS 20 FEET IN WIDTH. THERE ARE NO
 DIMENSIONS ON THE EXISTING DRIVE OR THE PROPOSED 'NEW
 PAVING AREA' IF THE TOTAL WIDTH OF THE DRIVE EXCEEDS 20
 FEET, THEN THE ADDITIONAL WORK WILL NOT BE ALLOWED.
 ALSO, CALCULATION FOR THE FRONT AREA SHALL BE PROVIDED
 BETWEEN THE FIRST 25 FEET OF LOT DEPTH FROM THE FRONT
 PROPERTY LINE MULTIPLIED BY THE TOTAL WIDTH OF THE
 PROPERTY. SHOW CALCULATION OF LANDSCAPE AREA ON THE
 LANDSCAPE PLAN.
  
  
 5. THE APPLICANT IS REQUESTED TO CLARIFY WHY THE
 PROPOSED 'DRESSING ROOM' APPEARS TO HAVE A KITCHEN,
 SEPERATE ENTRY, PHONE OUTLETS, NEW SEWER LINES, ETC.
 PLEASE BE ADVISED; THE SUBJECT PROPERTY IS LOCATED
 WITHIN AN SF7 ZONING DISTRICT, WHICH ONLY PERMITS
 SINGLE FAMILY USES.
  
  
 MURRIAH DEKLE, MPA, PLANNER
 PLANNING & ZONING DIVISION
 TEL: (561) 822-1442
 EMAIL: [email protected]
  
  
  
2013-04-03 10:03:204/3/13