Plan Review Details - Permit 13030845
Plan Review Stops For Permit 13030845
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-04-17 Cont ID  
Sent By shill Date 2013-04-17 Time 17:51 Rev Time 0.00
Received By shill Date 2013-04-17 Time 17:51 Sent To  
Notes
2013-04-17 17:52:35****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. PROVIDE A LEGIBLE PLAN TO PROVIDE THE FOLLOWING
 INFORMATION:
  
 TOTAL NUMBER OF PARKING SPACES
 NUMBER OF ACCESSIBLE SPACES
 LOCATION OF ACCESSIBLE ENTRANCES
 LOCATION OF ACCESSIBLE SPACES AND ACCESS AISLES
 SHOW ACCESSIBLE ROUTE FROM PUBLIC WAY
 ACCESSIBLE ROUTE FROM ACCESSIBLE SPACE TO ACCESSIBLE
 ENTRANCE
  
 SEE FBC 2010 ACCESSIBLITY 202.3 (ALTERATIONS), 208.2
 (PARKING SPACES), 502 (PARKING SPACES), 206 (ACCESSIBLE
 ROUTE).
  
 YOU MAY FIND THE FOLLOWING DOCUMENT USEFUL,
 PARTICULARLY THE INTRODUCTION: "WHEN A BUSINESS
 RESTRIPES A PARKING LOT, IT MUST PROVIDE ACCESSIBLE
 PARKING SPACES AS REQUIRED BY THE ADA STANDARDS FOR
 ACCESSIBLE DESIGN."
  
 HTTP://WWW.ADA.GOV/RESTRIPE.HTM
  
 2. FBC 2010 ACCESSIBILITY ADVISORY 502.3, WHERE THE
 ACCESSIBLE ROUTE MUST CROSS VEHICULAR TRAFFIC LANES,
 MARKED CROSSINGS ENHANCE PEDESTRIAN SAFETY; PLEASE
 INDICATE LOCATION ON PLAN.
  
 3. THE INDIVIDUAL TAKING RESPONSIBILITY SHALL PROVIDE
 THEIR PRINTED NAME AND SIGNATURE ON THE PLAN, FBC 107.
  
 4. TWO SETS REQUIRED FOR PERMIT ISSUANCE FBC 107.

Review Stop ENG ENGINEERING CSD
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2013-04-17 Cont ID  
Sent By mgonzale Date 2013-04-17 Time   Rev Time 0.50
Received By mgonzale Date 2013-04-17 Time   Sent To Z
Notes
2013-04-17 11:39:44PROVIDE UNITY OF TITLE FOR PROPERTIES.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status   Date 2013-05-16 Cont ID  
Sent By jwitmer Date 2013-05-16 Time 12:23 Rev Time 0.00
Received By jwitmer Date   Time   Sent To Z
Notes
2013-05-16 12:23:11INCOMING SENT TO ZONING BOX. JW

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-04-17 Cont ID  
Sent By shill Date 2013-04-17 Time 17:52 Rev Time 0.00
Received By shill Date 2013-03-28 Time 11:22 Sent To  
Notes
2013-03-29 11:22:20SENT TO ZONING SHELF FOR REVIEW. JG.

Review Stop Z ZONING
Rev No 2 Status F Date 2013-05-30 Cont ID  
Sent By ajones Date 2013-05-30 Time 12:33 Rev Time 0.00
Received By ajones Date 2013-05-21 Time 15:29 Sent To ENG
Notes
2013-05-30 12:45:075/30/13- FAILED. APPLICANT MUST BRING THE PROPOSED
 PARKING LOT UP TO LANDSCAPE CODE.
  
 AANGELLA JONES
 561-822-1441
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2013-04-04 Cont ID  
Sent By mdekle Date 2013-04-04 Time   Rev Time 0.00
Received By mdekle Date 2013-04-04 Time 15:45 Sent To ENG
Notes
2013-04-04 14:42:49ZONING PLAN REVIEW
 REVIEW STATUS: FAILED
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 1. THE APPLICANT MUST PROVIDE A PARKING PLAN DEPICTING
 THE STRIPING DETAIL WHICH DEMONSTRATES COMPLIANCE WITH
 THE MINIMUM DIMENSION STANDARDS FOUND WITHIN SECTIONS
 94-485 OF THE ZLDR. PLEASE INCLUDE DRIVE AISLE WIDTH
 DIMENSIONS AS WELL AS, THE PARKING STALL DIMENSIONS.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME AND/OR
 CONSULT THE CITY'S ZONING AND LAND DEVELOPMENT
 REGULATIONS ONLINE @WWW.MUNICODE.COM.
  
 MURRIAH DEKLE, MPA, PLANNER
 PLANNING & ZONING DIVISION
 TEL: (561) 822-1442
 EMAIL: [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved