Plan Review Details - Permit 13030791
Plan Review Stops For Permit 13030791
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2013-04-03 Cont ID  
Sent By jwitmer Date 2013-04-03 Time 16:03 Rev Time 0.00
Received By jwitmer Date 2013-04-03 Time 16:03 Sent To  
Notes
2013-04-03 16:06:42BUILDING PLAN REVIEW
 REVISION: 13030791
 PERMIT: 13020795
 ADD: 143 S. SEQEUOIA DR.
 CONT: OWNER/BUILDER
 MARILYN & WINSTON MCARTHUR
 TEL: (561)471-3173
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE- BUILDING.
  
 BUILDING PROVISO: SLOPE NOT PROVIDED.
 2010 FBC-B R905.2 ASPHALT SHINGLES.
  
 R905.2.2 SLOPE.
 ASPHALT SHINGLES SHALL ONLY BE USED ON ROOF SLOPES OF
 TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL (2:12) OR
 GREATER. FOR ROOF SLOPES FROM TWO UNITS VERTICAL IN 12
 UNITS HORIZONTAL (2:12) UP TO FOUR UNITS VERTICAL IN 12
 UNITS HORIZONTAL (4:12), TWO LAYERS OF UNDERLAYMENT
 COMPLYING WITH ASTM D 226, TYPE I OR TYPE II, ASTM D
 4869, TYPE I OR TYPE II OR ASTM D 6757 IS REQUIRED IN
 ACCORDANCE WITH SECTION R905.2.7.
  
 R905.2.7 UNDERLAYMENT APPLICATION.
 FOR ROOF SLOPES FROM TWO UNITS VERTICAL IN 12 UNITS
 HORIZONTAL (17-PERCENT SLOPE), UP TO FOUR UNITS
 VERTICAL IN 12 UNITS HORIZONTAL (33-PERCENT SLOPE), TWO
 LAYERS OF UNDERLAYMENT COMPLYING WITH ASTM D 226 TYPE I
 OR TYPE II, ASTM D 4869 TYPE I OR TYPE II, OR ASTM D
 6757 SHALL BE APPLIED IN THE FOLLOWING MANNER:
 1. APPLY A MINIMUM 19-INCH-WIDE (483 MM) STRIP OF
 UNDERLAYMENT FELT PARALLEL WITH AND STARTING AT THE
 EAVES.
 2. STARTING AT THE EAVE, APPLY 36-INCH-WIDE (914 MM)
 SHEETS OF UNDERLAYMENT OVERLAPPING SUCCESSIVE SHEETS 19
 INCHES (483 MM). DISTORTIONS IN THE UNDERLAYMENT SHALL
 NOT INTERFERE WITH THE ABILITY OF THE SHINGLES TO SEAL.
 3. END LAPS SHALL BE OFFSET BY 6 FEET (1829 MM).
 4. CORROSION RESISTANT FASTENERS ARE TO BE APPLIED
 ALONG THE OVERLAP AT A MAXIMUM SPACING OF 36 INCHES
 (914 MM) ON CENTER.
 FOR ROOF SLOPES OF FOUR UNITS VERTICAL IN 12 UNITS
 HORIZONTAL (33-PERCENT SLOPE) OR GREATER, ONE LAYER OF
 UNDERLAYMENT COMPLYING WITH ASTM D 226 TYPE I OR TYPE
 II, ASTM D 4869 TYPE I OR TYPE II, OR ASTM D 6757 SHALL
 BE APPLIED IN THE FOLLOWING MANNER:
  
 1. UNDERLAYMENT SHALL BE APPLIED SHINGLE FASHION,
 PARALLEL TO AND STARTING FROM THE EAVE AND LAPPED 2
 INCHES (51 MM).
 2. END LAPS SHALL BE OFFSET BY 6 FEET (1829 MM).
 3. CORROSION RESISTANT FASTENERS ARE TO BE APPLIED
 ALONG THE OVERLAP AT A MAXIMUM SPACING OF 36 INCHES
 (914 MM) ON CENTER.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-04-03 Cont ID  
Sent By jwitmer Date 2013-04-03 Time 16:04 Rev Time 0.00
Received By jwitmer Date 2013-03-27 Time 15:05 Sent To  
Notes
2013-03-27 15:05:15TO JW