Plan Review Details - Permit 13030746
Plan Review Stops For Permit 13030746
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2013-05-28 Cont ID  
Sent By jgomez Date 2013-05-28 Time 11:45 Rev Time 0.00
Received By jgomez Date 2013-05-28 Time 11:42 Sent To  
Notes
2013-05-28 11:48:18RECEIVED CONTRACTOR'S E-MAIL STATING THAT REPLACING
 EXISTING SINGLE HUNG WINDOWS WITH NEW SINGLE HUNG
 IMPACT WINDOWS. JG.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2013-05-09 Cont ID  
Sent By jgomez Date 2013-05-09 Time 13:20 Rev Time 0.00
Received By jgomez Date 2013-05-09 Time 13:20 Sent To  
Notes
2013-05-09 13:54:58RESIDENTIAL (R3) REPAIRS SECOND BUILDING REVIEW
 COMMENTS.
 CODE: 2010 FBC.
  
 1- SPECIFY TYPE OF EXISTING BEDROOM WINDOWS TO BE
 REPLACED TO VERIFY COMPLIANCE WITH THE EGRESS
 REQUIREMENTS. SEC. 604 OF 2010 FBC-EXISTING BUILDING.
  
 ***NOTE: ONLY THE SIZE OF WINDOWS WAS PROVIDED. TYPE OF
 EXISTING WINDOWS WAS NOT PROVIDED.
  
 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) FLAT ROOF. CLEARLY SPECIFY WHICH APPROVED ASSEMBLY
 IS GOING TO BE INSTALLED AND PROVIDE SIGNED AND SEALED
 RAS 117 CALCULATIONS IF THE PRODUCT APPROVAL SUBMITTED
 REQUIRES SIGNED AND SEALED CALCULATIONS.
  
 ***NOTE: ROOFING CONTRACTOR IS REQUIRED TO APPLY FOR
 THE ROOFING PERMIT.
  
 ***NOTE: THIS MAY BE PROVIDED BY THE ROOFING CONTRACTOR
 WHEN APPLYING FOR THE ROOFING PERMIT. THIS NOTE WILL BE
 REMOVED WHEN ITEM #1 ABOVE IS PROVIDED AND ROOFING
 CONTRACTOR PROVIDE THE REQUIRED INFORMATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-04-01 Cont ID  
Sent By jgomez Date 2013-04-01 Time 16:18 Rev Time 0.00
Received By jgomez Date 2013-04-01 Time 16:11 Sent To  
Notes
2013-04-01 16:21:36RESIDENTIAL (R3) REPAIRS BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) FLAT ROOF. CLEARLY SPECIFY WHICH APPROVED ASSEMBLY
 IS GOING TO BE INSTALLED AND PROVIDE SIGNED AND SEALED
 RAS 117 CALCULATIONS IF THE PRODUCT APPROVAL SUBMITTED
 REQUIRES SIGNED AND SEALED CALCULATIONS.
  
 ***NOTE: ROOFING CONTRACTOR IS REQUIRED TO APPLY FOR
 THE ROOFING PERMIT.
  
 B) GARAGE DOOR THAT MEETS THE DESIGN PRESSURES. NOTE:
 THIS BUILDING IS LOCATED ON EXPOSURE "C". FLORIDA
 PRODUCT APPROVAL FL15279 SUBMITTED DOESN'T MEET THE
 REQUIRED DESIGN PRESSURES FOR EXPOSURE "C".
  
 2- SPECIFY TYPE AND SIZE OF EXISTING BEDROOM WINDOWS TO
 BE REPLACED TO VERIFY COMPLIANCE WITH THE EGRESS
 REQUIREMENTS. SEC. 604 OF 2010 FBC-EXISTING BUILDING.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 3 Status N Date 2013-05-28 Cont ID  
Sent By jgomez Date 2013-05-28 Time 13:09 Rev Time 0.00
Received By jgomez Date 2013-05-28 Time 13:09 Sent To  
Notes
2013-05-28 13:11:02ELECTRICAL CONTRACTOR APPLIED FOR PERMIT UNDER SEPARATE
 PERMIT #13041004. JG.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2013-04-29 Cont ID  
Sent By rmcdouga Date 2013-04-29 Time 14:34 Rev Time 0.00
Received By rmcdouga Date 2013-04-29 Time 14:34 Sent To  
Notes
2013-04-29 15:12:042010 FBC / 2008 NEC
  
 DENIED BY ELECTRIC
  
 1) THE COMMENTS FROM THE FIRST ELECTRICAL REVIEW HAVE
 NOT BEEN ADDRESSED. SEE FIRST REVIEW.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2013-04-01 Cont ID  
Sent By rlecky Date 2013-04-01 Time 13:16 Rev Time 0.00
Received By rlecky Date 2013-04-01 Time 13:11 Sent To  
Notes
2013-04-01 13:16:43PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING
 ELECTRICAL REVIEW COMMENTS.
  
 ELECTRICAL PLANS ARE REQUIRED. PROVIDE AN ELECTRICAL
 RISER PLAN SHOWING THE PANEL, MAIN BREAKER, GROUNDING,
 FEEDERS AND BRANCH CIRCUITS. INCLUDE A LOAD CALCULATION
 AND PANEL DIRECTORY. SHOW LOCATION OF THE ELECTRICAL
 PANEL WITH REQUIRED SAFE WORKING CLEARANCES. INDICATE
 THE SIZE AND LOCATION OF THE ELECTRICAL PANEL. ON A
 FLOOR PLAN SHOW THE LOCATION OF ALL NEW LIGHTING
 OUTLETS, RECEPTACLE OUTLETS AND SMOKE DETECTORS. NEC
 215.5, 210.50, 110.26. 107.2.1
  
 SHOW THE KITCHEN COUNTER TOP RECEPTACLES TO BE GFCI
 PROTECTED. NEC 210.8
  
 REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO
 INCLUDE INTERCONNECTED SMOKE ALARMS BOTH WITHIN AND
 OUTSIDE EACH SLEEPING AREA. IF THE RESIDENCE HAS GAS
 APPLIANCES, AN ATTACHED GARAGE OR A FIRE PLACE A CARBON
 MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET OF EACH
 ROOM USED FOR SLEEPING. 2010 FBC R314, 315
  
 NEW RECEPTACLES MUST BE TAMPER RESISTANT. NEC 406.11
  
 ARC FAULT CIRCUIT PROTECTION IS REQUIRED FOR ALL NEW
 GENERAL PURPOSE OUTLETS INCLUDING LIGHTING. NEC 210.12
  
 THE BATHROOM REQUIRES A DEDICATED 20 AMP BRANCH
 CIRCUIT. NEC 210.11 (C) (3)
  
 A GFCI PROTECTED RECEPTACLE IS REQUIRED OUTSIDE AT THE
 FRONT AND BACK ENTRANCE AREA. NEC 210.52 (E) (1)
  
 AN INTERSYSTEM BONDING STRIP IS REQUIRED AT THE MAIN
 SERVICE GROUND. NEC 250.94
  
  
  
 ROBERT LECKY
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6718
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2013-05-28 Cont ID  
Sent By jgomez Date 2013-05-28 Time 11:40 Rev Time 0.00
Received By jgomez Date 2013-05-28 Time 11:40 Sent To  
Notes
2013-05-28 11:42:08CONTRACTOR'S RESPONSE STATING TYPE OF EXISTING WINDOWS.
 REPLACING SINGLE HUNG WINDOWS WITH SINGLE HUNG WINDOWS.
 LIKE FOR LIKE. JG.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-05-09 Cont ID  
Sent By jgomez Date 2013-05-09 Time 14:10 Rev Time 0.00
Received By jgomez Date 2013-04-29 Time 15:12 Sent To  
Notes
2013-04-29 15:12:54SENT TO J GOMEZ.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-04-03 Cont ID  
Sent By mdekle Date 2013-04-03 Time   Rev Time 0.00
Received By mdekle Date 2013-03-26 Time 16:52 Sent To  
Notes
2013-03-26 16:53:57INCOMING SENT TO R-05 BOX. JW

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2013-05-28 Cont ID  
Sent By jgomez Date 2013-05-28 Time 13:15 Rev Time 0.00
Received By jgomez Date 2013-05-28 Time 13:15 Sent To  
Notes
2013-05-28 13:16:21PROVIDE COMPLETE INFORMATION UNDER A SEPARATE PERMIT.
 JG.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2013-05-09 Cont ID  
Sent By jgomez Date 2013-05-09 Time 14:08 Rev Time 0.00
Received By jgomez Date 2013-05-09 Time 14:08 Sent To  
Notes
2013-05-09 14:09:56RESIDENTIAL (R3) REPAIRS SECOND MECHANICAL REVIEW
 COMMENTS.
 CODE: 2010 FBC.
  
 ***NOTE: COMMENTS WERE NOT ADDRESSED.
  
 1- PROVIDE A) EQUIPMENT SIZING CALCULATIONS, B)
 COMPLETE ENERGY CALCULATIONS, C) COMPLETE A/C PLANS AS
 REQUIRED BY TABLE 101.4.1 OF 2010 FBC-ENERGY
 CONSERVATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2013-04-02 Cont ID  
Sent By jgomez Date 2013-04-02 Time 10:44 Rev Time 0.00
Received By jgomez Date 2013-04-02 Time 10:44 Sent To  
Notes
2013-04-02 11:17:12RESIDENTIAL (R3) REPAIRS MECHANICAL REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- PROVIDE A) EQUIPMENT SIZING CALCULATIONS, B)
 COMPLETE ENERGY CALCULATIONS, C) COMPLETE A/C PLANS AS
 REQUIRED BY TABLE 101.4.1 OF 2010 FBC-ENERGY
 CONSERVATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop P PLUMBING
Rev No 1 Status P Date 2013-04-02 Cont ID  
Sent By jgomez Date 2013-04-02 Time 10:44 Rev Time 0.00
Received By jgomez Date 2013-04-02 Time 10:44 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status N Date 2013-05-28 Cont ID  
Sent By jgomez Date 2013-05-28 Time 13:30 Rev Time 0.00
Received By jgomez Date 2013-05-28 Time 13:26 Sent To  
Notes
2013-05-28 13:31:00ROOFING PERMIT DONE UNDER PERMIT #13050349. JG.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2013-05-09 Cont ID  
Sent By jgomez Date 2013-05-09 Time 13:59 Rev Time 0.00
Received By jgomez Date 2013-05-09 Time 13:59 Sent To  
Notes
2013-05-09 14:07:44RESIDENTIAL (R3) ROOFING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
  
 A) FLAT ROOF. AND, CLEARLY SPECIFY WHICH APPROVED
 ASSEMBLY IS GOING TO BE INSTALLED. ALSO, PROVIDE THE
 RAS 117 CALCULATIONS FOR NAIL ENHANCING AT PERIMETER
 AND CORNER AREAS AS REQUIRED TO MEET THE DESIGN
 PRESSURES OF SEC. R301.2.1.4.3 OF 2010 FBC-RESIDENTIAL.
 SEE GENERAL LIMITATION #7 ON LAST PAGE OF THE NOA
 SUBMITTED. IF THE NOA PROVIDED REQUIRES SIGNED AND
 SEALED RAS 117 CALCULATIONS, THEN, SIGNED AND SEALED
 CALCULATIONS ARE REQUIRED.
  
 ***NOTE: THIS MAY BE PROVIDED BY THE ROOFING CONTRACTOR
 WHEN APPLYING FOR THE ROOFING PERMIT. THIS NOTE WILL BE
 REMOVED WHEN ITEM ABOVE IS PROVIDED AND ROOFING
 CONTRACTOR PROVIDES THE REQUIRED INFORMATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop Z ZONING
Rev No 1 Status N Date 2013-04-03 Cont ID  
Sent By mdekle Date 2013-04-03 Time   Rev Time  
Received By mdekle Date 2013-04-03 Time   Sent To  
Notes
2013-04-03 09:54:554/3/13