| 2013-04-23 16:45:47 | ****CORRECTIONS**** |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | FBC FLORIDA BUILDING CODE 2010 |
| | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL |
| | |
| | FROM PREVIOUS REVIEW: |
| | |
| | 1. REVISE THE FLOOR PLAN TO SHOW ROOM DESIGNATIONS. IF |
| | NON COMPLIANT EMERGENCY ESCAPE AND RESCUE OPENINGS ARE |
| | PROPOSED, ALSO NOTE EXISTING CONDITIONS (TYPE OF |
| | WINDOW) AND EXISTING CLEAR OPENING SIZE AND PROPOSED |
| | CLEAR OPENING SIZE FOR BEDROOMS, FBC R310, FBC EB |
| | 604.1. THE CLEAR OPENING CANNOT BE REDUCED BY MORE THAN |
| | 5%. |
| | |
| | 2ND REVIEW, CLEAR OPENING FOR EGRESS IS THE CLEAR |
| | OPENING WHEN THE WINDOW IS OPEN. PLEASE REVISE PLAN TO |
| | INCLUDE REQUESTED INFORMATION (EXISTING CLEAR OPENING, |
| | PROPOSED NEW). |
| | |
| | 2. PROVIDE A COPY OF TH CONTRACT FOR THIS JOB FBC 109. |
| | |
| | 2ND REVIEW, AS THE CONTRACTOR IS OWNER, PROVIDE |
| | MATERIAL RECEIPT. |
| | |
| | 3. TWO SETS REQUIRED; ONLY ONE SET OF WINDOW PRODUCT |
| | APPROVALS WAS SUBMITTED. THREE SETS OF THE SLIDING |
| | GLASS DOOR NOA WAS SUBMITTED. FBC 107. |
| | |
| | 2ND REVIEW, A DIFFERENT PRODUCT APPROVAL WAS PROVIDED. |
| | FIRST SUBMITTAL WAS A MIAMI DADE NOA (ONE SET), AND |
| | RESUB INCLUDED A PARTIAL FLORIDA STATE PRODUCT |
| | APPROVAL. |
| | |
| | PLEASE SELECT WHICH PRODUCT APPROVAL YOU'D LIKE TO USE |
| | FOR PERMITTING PURPOSES. IF THE FLORIDA STATE PRODUCT |
| | APPROVAL IS USED, PROVIDE THE FLORIDA STATE PRODUCT |
| | APPROVAL COVER SHEET FROM THE WEBSITE |
| | WWW.FLORIDABUILDING.ORG, EVALUATION REPORT AND |
| | INSTALLATION INSTRUCTIONS. THE DOCUMENT IS TO BE |
| | LEGIBLE. THE EVALUATION REPORT SUBMITTED WAS NOT |
| | PRINTED IN A LEGIBLE MANNER (NOT ALL INFORMATION ON THE |
| | SHEET PRINTED). |
| | |