Plan Review Details - Permit 13030556
Plan Review Stops For Permit 13030556
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2013-04-16 Cont ID  
Sent By shill Date 2013-04-16 Time 12:51 Rev Time 0.00
Received By shill Date 2013-04-16 Time 12:51 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2013-04-12 Cont ID  
Sent By mgonzale Date 2013-04-12 Time   Rev Time 1.00
Received By mgonzale Date 2013-04-12 Time   Sent To I
Notes
2013-04-12 10:30:35PASSED WITH PROVISOS
  
 #1 IT IS UNDERSTOOD THAT NEW ASPHALT IS BEING APPLIED
 TO WORN OUT SURFACE AND IT WILL NOT ALTER THE SITE
 ELEVATION.
  
 #2 IT IS UNDERSTOOD THE NEW ASPHALT IS BEING APPLIED AS
 PART OF ROUTINE MAINTENANCE AND CODE COMPLIANCE.
  
 #3 IT IS UNDERSTOOD THAT SITE WILL COMPLY WITH WATER
 QUALITY CRITERIA
 A. RETENTION/DETENTION REQUIREMENTS
 1. VOLUME IS CALCULATED AS:
 A) WET DETENTION VOLUME SHALL BE PROVIDED FOR THE FIRST
 INCH OF RUNOFF FROM THE DEVELOPED PROJECT, OR THE TOTAL
 RUNOFF OF 2.5-INCHES TIMES THE PERCENTAGE OF
 IMPERVIOUSNESS, WHICHEVER IS GREATER, B) DRY DETENTION
 VOLUME SHALL BE PROVIDED EQUAL TO 75% OF THE ABOVE
 AMOUNTS COMPUTED FOR WET DETENTION.
 C) RETENTION VOLUME SHALL BE PROVIDED EQUAL TO 50% OF
 THE ABOVE AMOUNTS COMPUTED FOR WET DETENTION. RETENTION
 VOLUME INCLUDED IN FLOOD PROTECTION CALCULATIONS
 REQUIRES A GUARANTEE OF LONG TERM OPERATION AND
 MAINTENANCE OF SYSTEM BLEED-DOWN ABILITY. D) SYSTEMS
 WITH INLETS IN GRASSED AREAS WILL BE CREDITED WITH UP
 TO 0.2-INCHES OF THE REQUIRED WET DETENTION AMOUNT FOR
 THE CONTRIBUTING AREAS. FULL CREDIT WILL BE BASED ON A
 RATIO OF 10:1 IMPERVIOUS AREA TO PERVIOUS AREA.
  
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-04-16 Cont ID  
Sent By shill Date 2013-04-16 Time 12:51 Rev Time 0.00
Received By shill Date 2013-03-19 Time 16:32 Sent To  
Notes
2013-03-19 16:33:08INCOMING SENT TO ZONING BOX. JW

Review Stop Z ZONING
Rev No 2 Status P Date 2013-04-10 Cont ID  
Sent By mdekle Date 2013-04-10 Time   Rev Time 0.00
Received By mdekle Date 2013-04-10 Time 09:17 Sent To ENG
Notes
2013-04-10 09:32:10** PASSED W/PROVISO **
 ALL PARKING STALLS MUST MEET THE CITY STANDARDS
 ATTACHED TO THE PLANS, IN COMPLIANCE WITH
 SECTION 94-485 OF THE ZLDR
 MURRIAH DEKLE, MPA, PLANNER
 PLANNING & ZONING DIVISION
 TEL: (561) 822-1442
 EMAIL: [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2013-03-27 Cont ID  
Sent By mdekle Date 2013-03-27 Time   Rev Time  
Received By mdekle Date 2013-03-20 Time   Sent To ENG
Notes
2013-03-27 08:14:51ZONING PLAN REVIEW
 REVIEW STATUS: FAILED
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
  
 1. THE APPLICANT MUST PROVIDE ADDITIONAL INFORMATION
 INCLUDING THE FOLLOWING:
 A. PARKING STALL DIMENSIONS IN ACCORDANCE WITH SECTION
 94-485.
 B. PARKING DATA INCLUDING THE USE FOR THE SITE/BUILDING
 TO DETERMINE THE NUMBER OF PARKING STALLS REQUIRED VS
 PROVIDED.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME AND/OR
 CONSULT THE CITY?S ZONING AND LAND DEVELOPMENT
 REGULATIONS ONLINE @WWW.MUNICODE.COM.
  
 MURRIAH DEKLE, MPA, PLANNER
 PLANNING & ZONING DIVISION
 TEL: (561) 822-1442
 EMAIL: [email protected]
  