Plan Review Details - Permit 13030418
| Plan Review Stops For Permit 13030418 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2013-04-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-04-17 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-04-17 |
Time |
16:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2013-03-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-03-22 |
Time |
18:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-03-22 |
Time |
18:47 |
Sent To |
|
|
| Notes |
| 2013-03-22 18:52:31 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. PROPOSED DESIGN PRESSURES ARE TOO LOW. FOR INSTANCE | | | - OPENING AT BEDROOM 53X54, PROPOSED DP IS +-39.9, | | | ASCE7 REQUIRES A DESIGN PRESSURE OF +46.65/-50.78. | | | | | | EITHER PROVIDE ENGINEERING FOR THE DESIGN PRESSURES | | | PROPOSED OR REVISE FLOOR PLAN AND PRODUCT APPROVAL | | | MARKINGS TO COMPLY WITH WORST CASE FOR THIS JOB WHICH | | | IS +46.65/-50.78 IF ALL OPENINGS ARE IN ZONE 4. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-03-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-03-15 |
Time |
17:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-03-15 |
Time |
17:09 |
Sent To |
|
|
| Notes |
| 2013-03-15 17:11:45 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. INDICATE WHICH OPTION IS PROPOSED BY CIRCLING OR | | | OTHERWISE INDICATING ON SHEET 2 OR 3. EITHER STATE | | | PROPOSED DESIGN PRESSURES OR PROVIDE MEAN ROOF HEIGHT | | | SO THAT DESIGN PRESSURES CAN BE DETERMINED FOR YOU, FBC | | | 1609. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-04-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-04-17 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-04-09 |
Time |
11:41 |
Sent To |
|
|
| Notes |
| 2013-04-11 11:41:34 | SENT TO SAMANTHA'S DESK FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-03-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-03-22 |
Time |
18:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-03-22 |
Time |
18:44 |
Sent To |
|
|
| Notes |
| 2013-03-22 18:44:51 | TO SH DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-03-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-03-15 |
Time |
17:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-03-15 |
Time |
17:11 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy