| Plan Review Stops For Permit 13030161 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2013-06-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-06-03 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-06-03 |
Time |
09:29 |
Sent To |
|
|
| Notes |
| 2013-06-03 09:33:53 | BUILDING PLAN REVIEW | | | PERMIT: 13030161 | | | ADD: 5908 GEORGIA AVE | | | CONT: IDEAL FLOORING & REMODELING | | | TEL: (561)523-9643 | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE: 6/03/2013 | | | ACTION: PROVISO | | | BUILDING APPROVED WITH EXCEPTION! | | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE | | | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. | | | | | | 1) THE NEW 45MINUTE FIRE RATED ROLL UP DOOR ON EAST | | | EXPOSURE WILL NEED PRODUCT APPROVALS FOR: | | | 1A) 45 MINUTE FIRE RATING | | | 1B) LARGE MISSILE IMPACT TESTING BEFORE FIRST | | | INSPECTION | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2013-04-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-04-19 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-04-19 |
Time |
12:30 |
Sent To |
|
|
| Notes |
| 2013-04-19 13:03:10 | BUILDING PLAN REVIEW | | | PERMIT: 13030161 | | | ADD: 5908 GEODGIA AVE | | | CONT: IDEAL FLOORING & REMODELING | | | TEL: (561)523-9643 | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: 4/19/2013 | | | ACTION: DENIED | | | | | | 1)COMPLIED. | | | | | | 2) 2ND REVIEW. THE NEWLY FORMED DISPLAY SPACE # 3 IS A | | | TOTALLY ENCLOSED SPACE FROM THE FORMER MEZZANINE. THE | | | AREA ABOVE THE DISPLAY SPACE # 3 WILL BE CONSIDERED A | | | 2N FLOOR. IT CAN NO LONGER MEET THE REQUIREMENT OF 1/3 | | | THE COMMUNICATING AREA ON THE FIRST FLOOR. THE ENCLOSED | | | AREA BELOW NO LONGER IS WITHIN THE SAME ROOM. THE PLANS | | | WILL NEED TO INDICATE A SECOND FLOOR, NOT MEZZANINE. | | | PLEASE REVIEW YOUR OCCUPANT LOAD FOR THE STORAGE ON THE | | | SECOND FLOOR (STORAGE AT 300 SQ FT) / OCCUPANT WILL PUT | | | YOU AT 4 OCCUPANTS FOR THE SECOND FLOOR AREA. | | | | | | PLEASE REVIEW 1022.1 EXCEPTION 1 AND 1.1 FOR THE 2ND | | | STORY EGRESS. | | | | | | 3) 2ND REVIEW , IF THE COVER SHEET IS CORRECT WITH THE | | | SQUARE FOOTAGE FOR THE SECOND FLOOR THEN PLEASE SHOW | | | THE SECOND FLOOR LEVEL AND EXITING OF THE 2ND FLOOR. | | | MINIMUM PLAN REVIEW CRITERIA FOR REQUIREMENTS FOR | | | COMMERCIAL PLAN REVIEW. 107.3.5 | | | FLOOR PLANS- SECOND FLOOR | | | FIRE-RESISTANT SEPARATIONS | | | FIRE-RESISTANT PROTECTION FOR TYPE OF CONSTRUCTION | | | PROTECTION OF OPENINGS AND PENETRATIONS OF RATED WALLS | | | | | | LIFE SAFETY SYSTEMS SHALL BE DETERMINED AND SHALL | | | INCLUDE THE FOLLOWING REQUIREMENTS: | | | MEANS OF EGRESS | | | EXIT ACCESS | | | EXIT | | | EXIT DISCHARGE | | | STAIRS CONSTRUCTION/GEOMETRY AND PROTECTION | | | | | | 4) 2ND REVIEW, ON SHEET D1 & A1 ON THE EAST WALL THE | | | PLANS INDICATE CUTTING IN A NEW DOORWAY THE SITE PLAN | | | (COVER SHEET) WHEN SCALED INDICATES 3'-0" TO THE | | | PROPERTY LINE, PLEASE PROVIDE COMPLIANCE WITH SECTIONS | | | 2010 FBC-B TABLE 602 & TABLE 705.8 FOR EXISTING | | | OPENINGS AND THE NEW PROPOSED OPENING. | | | | | | 5) COMPLIED. | | | | | | 6) COMPLIED. | | | | | | 7) 2ND REQUEST. THE PLANS INDICATE NEW EXTERIOR | | | OPENINGS PLEASE REVIEW THE FOLLOWING; | | | 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 8) 2ND REQUEST. 2010 FBC-B 1609.1.2 PROTECTION OF | | | OPENINGS, 1609.6.4.41 COMPONENTS & CLADDING | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS | | | | | | 9) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-03-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-03-21 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-03-20 |
Time |
16:25 |
Sent To |
|
|
| Notes |
| 2013-03-21 11:48:12 | BUILDING PLAN REVIEW | | | PERMIT: 13030161 | | | ADD: 5908 GEODGIA AVE | | | CONT: IDEAL FLOORING & REMODELING | | | TEL: (561)523-9643 | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: 3/21/2013 | | | ACTION: DENIED | | | | | | 1) THE COVER SHEET UNDER THE HEADING OF SITE DATA NOR | | | BUILDING INFORMATION DOES NOT PROVIDE THE MINIMUM | | | BUILDING TYPE 2010 FBC-B TABLE 503. | | | | | | 2) THE COVER SHEET INDICATES THE SQUARE FOOTAGE OF THE | | | BUILDING AS 4491 SQ FT AND A EXISTING MEZZANINE AS 3078 | | | SQ FT. IF THIS SQUARE FOOTAGE IS CORRECT THEN THE SO | | | CALLED MEZZANINE IS A TRUE SECOND FLOOR, SEE 2010 FBC-B | | | 505.2 AND EXCEPTIONS. PLEASE SHOW MEZZANINE LEVEL AND | | | EXITING. | | | | | | 3) IF THE COVER SHEET IS CORRECT WITH THE SQUARE | | | FOOTAGE FOR THE SECOND FLOOR THEN PLEASE SHOW THE | | | SECOND FLOOR LEVEL AND EXITING OF THE 2ND FLOOR. | | | MINIMUM PLAN REVIEW CRITERIA FOR REQUIREMENTS FOR | | | COMMERCIAL PLAN REVIEW. 107.3.5 | | | FLOOR PLANS- SECOND FLOOR | | | FIRE-RESISTANT SEPARATIONS | | | FIRE-RESISTANT PROTECTION FOR TYPE OF CONSTRUCTION | | | PROTECTION OF OPENINGS AND PENETRATIONS OF RATED WALLS | | | | | | LIFE SAFETY SYSTEMS SHALL BE DETERMINED AND SHALL | | | INCLUDE THE FOLLOWING REQUIREMENTS: | | | MEANS OF EGRESS | | | EXIT ACCESS | | | EXIT | | | EXIT DISCHARGE | | | STAIRS CONSTRUCTION/GEOMETRY AND PROTECTION | | | | | | 4) ON SHEET D1 & A1 ON THE EAST WALL THE PLANS INDICATE | | | CUTTING IN A NEW DOORWAY THE SITE PLAN (COVER SHEET) | | | WHEN SCALED INDICATES 3'-0" TO THE PROPERTY LINE, | | | PLEASE PROVIDE COMPLIANCE WITH SECTIONS 2010 FBC-B | | | TABLE 602 & TABLE 705.8 FOR EXISTING OPENINGS AND THE | | | NEW PROPOSED OPENING. | | | | | | 5) SHEET A1 DOES NOT INDICATE ANY OCCUPANCY SEPERATION | | | WALL BETWEEN THE WAREHOUSE AND THE NEW MERCANTILE | | | OCCUPANCY, PLANS DO NOT INDICATE IF THE WAREHOUSE IS A | | | S1 OR S2 OCCUPANCY PLEASE REVIEW 2010 FBC-B TABLE | | | 508.4. | | | | | | 6) SHEET A1 DOOR # 107 DOES NOT INDICATE BEING FIRE | | | RATED, AGAIN IT WILL DEPEND ON THE STORAGE OCCUPANCY | | | FOR THE FIRE RATING TABLE 508.4 AND TABLE 715.4. | | | | | | 7) THE PLANS INDICATE NEW EXTERIOR OPENINGS PLEASE | | | REVIEW THE FOLLOWING; | | | 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 8) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.41 COMPONENTS & CLADDING | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS | | | | | | 9) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2013-06-27 |
|
|
Cont ID |
|
| Sent By |
DHARVEY |
Date |
2013-06-27 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-06-27 |
Time |
14:23 |
Sent To |
|
|
| Notes |
| 2013-06-27 14:38:56 | RESTAMP FOR VB. RL |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2013-05-03 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-05-03 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-05-03 |
Time |
09:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2013-03-15 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2013-03-15 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2013-03-15 |
Time |
11:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2013-06-14 |
|
|
Cont ID |
|
| Sent By |
WJOLIN |
Date |
2013-06-14 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
lphilmor |
Date |
2013-06-14 |
Time |
15:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2013-04-20 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-04-20 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-04-20 |
Time |
10:40 |
Sent To |
|
|
| Notes |
| 2013-04-20 11:23:58 | 5908 GEORGIA AVENUE | | | PERMIT #13030161 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | RESPONSE COMMENT: THE OPEN AREA SQUARE FOOTAGE OF | | | EXISTING WAREHOUSE #101 IS APPROXIMATELY 1,765 SQ.FT. | | | WHICH WOULD ALLOW A MEZZANINE OF APPROXIMATELY 582 | | | SQ.FT. THE AREA INDICATED AS EXISTING MEZZANINE OF | | | 1,050 IS TOO LARGE TO BE MEZZANINE AND THEREFORE MUST | | | BE TREATED AS A SECOND FLOOR. THE MAXIMUM COMMON PATH | | | OF TRAVEL (50 FEET) IS EXCEEDED FOR A FLOOR WITH ONE | | | MEANS OF EGRESS IN A STORAGE OCCUPANCY. | | | ORIGINAL COMMENT: THE COVER SHEET INDICATES AN EXISTING | | | "MEZZANINE" OF 3,078 SQ.FT.; HOWEVER, NO EXISTING PLANS | | | OR PERMITS COULD BE LOCATED FOR THIS WORK. ALSO, THE | | | SIZE OF THE "MEZZANINE" APPEARS TO MEET THE DEFINITION | | | OF A TRUE SECOND FLOOR WHEREBY TWO EXITS ARE REQUIRED. | | | | | | NEW COMMENT: EACH FIRE BARRIER SHALL BE PERMANENTLY | | | IDENTIFIED WITH SIGNS OR STENCILING READING FIRE | | | BARRIER-PROTECT ALL OPENINGS. CHARACTERS SHALL BE AT | | | LEAST 4-INCHES IN HEIGHT AND HALF-INCH IN WIDTH. | | | IDENTIFICATION SHALL BE SPACED NOT MORE THAN 15 FEET ON | | | CENTER. | | | | | | WESLEY JOLIN | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2013-03-19 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-03-19 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-03-19 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2013-03-19 11:41:58 | 5908 GEORGIA AVENUE | | | PERMIT #13030161 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | THE PLANS INDICATE A BUSINESS OCCUPANCY AND WAREHOUSE | | | (ASSUMED TO BE STORAGE OCCUPANCY). PER NFPA 101 (W/ | | | FLORIDA AMENDMENTS - 2009 EDITION) SECTION 39.3.2, AN | | | EXISTING BUSINESS OCCUPANCY REQUIRES GENERAL STORAGE | | | AREAS TO BE SEPARATED FROM THE BUSINESS AREA WITH A | | | 1-HOUR FIRE RATED BARRIER (OR BE PROTECTED BY AUTOMATIC | | | FIRE SPRINKLERS). DOORS (#D107) SHALL BE SELF CLOSING, | | | POSITIVE LATCHING, AND FIRE-RATED FOR AT LEAST | | | 45-MINUTES PER SECTION 8.7 OF NFPA 101. DUCTWORK AND | | | OTHER PENETRATIONS SHALL BE PROPERLY PROTECTED. | | | | | | PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS | | | SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE | | | TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL | | | DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET. | | | | | | THUMB-TURN STYLE LOCKS TO BE EQUIPPED WITH A | | | LOCK/UNLOCK INDICATOR. | | | | | | THE COVER SHEET INDICATES AN EXISTING "MEZZANINE" OF | | | 3,078 SQ.FT.; HOWEVER, NO EXISTING PLANS OR PERMITS | | | COULD BE LOCATED FOR THIS WORK. ALSO, THE SIZE OF THE | | | "MEZZANINE" APPEARS TO MEET THE DEFINITION OF A TRUE | | | SECOND FLOOR WHEREBY TWO EXITS ARE REQUIRED. | | | | | | WESLEY JOLIN | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2013-06-28 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-06-28 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-06-28 |
Time |
13:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2013-06-27 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-06-27 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-06-03 |
Time |
12:04 |
Sent To |
|
|
| Notes |
| 2013-06-24 15:50:28 | B22 | | | | | 2013-06-14 12:06:53 | MOVED FROM B--23 | | | TO B--2 | | 2013-06-03 15:57:42 | B23 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-06-14 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2013-06-03 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2013-05-22 |
Time |
09:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-05-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-05-03 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-04-08 |
Time |
08:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-04-09 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2013-04-05 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-03-06 |
Time |
13:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
5 |
Status |
P |
Date |
2013-06-28 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-06-28 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-06-28 |
Time |
13:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
F |
Date |
2013-06-27 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-06-27 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-06-27 |
Time |
15:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2013-06-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-06-03 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-06-03 |
Time |
09:34 |
Sent To |
|
|
| Notes |
| 2013-06-03 09:34:54 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2013-04-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-04-09 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-04-09 |
Time |
08:18 |
Sent To |
|
|
| Notes |
| 2013-04-09 08:18:35 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2013-04-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-03-21 |
Time |
08:05 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-03-20 |
Time |
08:05 |
Sent To |
|
|
| Notes |
| 2013-04-09 08:06:03 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2013-06-27 |
|
|
Cont ID |
|
| Sent By |
HMOSER |
Date |
2013-06-27 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-06-17 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2013-06-27 14:38:13 | SEE PROVISIO ON PLANS FROM JW. RL | | 2013-06-17 16:23:25 | MECHANICAL PROVISO: | | | PROVIDE A DETAIL ON THE CURB TO ROOF TIE DOWN | | | AND RTU TO CURB TIE DOWN BY THE ENGINEER OF RECORD | | | BY 1ST INSPECTION. PER SECTION 2010 FBC-M 301.12 WIND | | | RESISTANCE. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2013-04-15 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-04-15 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-04-15 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2013-04-15 09:41:34 | PASS PROVISO | | | PROVIDE A DETAIL ON THE CURB TO ROOF | | | TIE DOWN AND RTU. TO CURB TIEDOWN | | | BY THE ENGINEER AT FIRST INSPECTION. | | | PER SECTION 301.12 WIND RESISTANCE. | | | 2010 FBC (M) | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2013-03-25 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-03-25 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-03-22 |
Time |
14:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2013-05-30 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-05-30 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-05-30 |
Time |
13:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2013-04-18 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-04-18 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-04-18 |
Time |
10:12 |
Sent To |
|
|
| Notes |
| 2013-04-18 10:38:29 | FBC 2010 EXISTING BUILDING CODE | | | FBC 2010 ACCESSIBILITY CODE | | | FBC 2010 PLUMBING REVIEW #2 | | | DENIED: | | | | | | COMMENT FOR REVIEW #1 NOTED. THE EXCEPTION FOR THE | | | BUSINESS DOES APPLY, HOWEVER, THE WAREHOUSE AREA WOULD | | | BE REQUIRED TO HAVE A RESTROOM PER TABLE 403.1 OR 2 | | | RESTROOMS FOR THE TOTAL OCCUPANCY. | | | FBC PLUMBING 403.2 SEPARATE FACILITIES ARE REQUIRED FOR | | | EACH SEX, WITH THE EXCEPTION (3) SEPARATE FACILITIES | | | SHALL NOT BE REQUIRED IN BUSINESS AND MERCANTILE | | | OCCUPANCIES WITH A TOTAL FLOOR AREA OF 3,000 SQUARE | | | FEET (279 M2) OR LESS. | | | SHEET SP 2 LISTS THE OCCUPANCY AS BUSINESS WITH UNDER | | | 3000 S.F. AND THE WAREHOUSE 3301 S.F. WITH THE TOTAL | | | OCCUPANT LOAD AS 34. TOTAL RESTROOMS REQUIRED IS 2. | | | TABLE P403.1 WAREHOUSE (STORAGE) = 1 PER 100 OCCUPANTS. | | | BUSINESS UNDER 3000 S.F. 1 RESTROOM REQUIRED. | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805-6692 | | | EMAIL [email protected] | | | FAX # 805-6676 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2013-03-11 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-03-11 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-03-11 |
Time |
13:47 |
Sent To |
|
|
| Notes |
| 2013-03-11 14:27:59 | FBC 2010 EXISTING BUILDING CODE | | | FBC 2010 ACCESSIBILITY CODE | | | FBC 2010 PLUMBING REVIEW #1 | | | DENIED: | | | | | | FBC PLUMBING 403.2 SEPARATE FACILITIES ARE REQUIRED FOR | | | EACH SEX, WITH THE EXCEPTION (3) SEPARATE FACILITIES | | | SHALL NOT BE REQUIRED IN BUSINESS AND MERCANTILE | | | OCCUPANCIES WITH A TOTAL FLOOR AREA OF 3,000 SQUARE | | | FEET (279 M2) OR LESS. | | | SHEET SP 1 LISTS THE OCCUPANCY AS BUSINESS WITH 7,924 | | | S.F. PLEASE PROVIDE THE OCCUPANCY TYPE/S AND OCCUPANT | | | LOAD FOR EACH TYPE. | | | | | | COMMERCIAL OCCUPANCIES SUCH AS BUSINESS, MERCANTILE, | | | STORAGE, ETC. REQUIRE A HI/LO DRINKING FOUNTAIN UNLESS | | | THERE ARE 15 OR LESS OCCUPANTS. | | | FBC PLUMBING TABLE 403.1(E, F) | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805-6692 | | | EMAIL [email protected] | | | FAX # 805-6676 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2013-06-26 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2013-06-26 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2013-06-26 |
Time |
15:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2013-05-28 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2013-05-28 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2013-05-28 |
Time |
09:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2013-04-11 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2013-04-11 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2013-04-11 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2013-04-11 13:52:51 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 04.11.2013 | | | PERMIT NO.: 13030161 | | | ADDRESS: 5908 GEORGIA AVENUE | | | CONTRACTOR/CONTACT: KEVIN PENNINGTON | | | TELEPHONE NO.: 561.523.9643 | | | SCOPE OF REVIEW: INTERIOR BUILD-OUT OF SHOWROOM. | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PLEASE PROVIDE A DETAIL OF THE PROPOSED METAL FENCE | | | AND SLIDING GATE. | | | 2. PLEASE PROVIDE TWO (2) COPIES OF A CURRENT / | | | ACCURATE SURVEY. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1448 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.WPB.ORG | | | | | | 3/14/13 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2013-04-04 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2013-04-04 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2013-04-04 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2013-04-04 11:07:15 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 04.04.2013 | | | PERMIT NO.: 13030161 | | | ADDRESS: 5908 GEORGIA AVENUE | | | CONTRACTOR/CONTACT: KEVIN PENNINGTON | | | TELEPHONE NO.: 561.523.9643 | | | SCOPE OF REVIEW: INTERIOR BUILD-OUT OF SHOWROOM. | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PLEASE PROVIDE A DETAIL OF THE PROPOSED METAL FENCE | | | AND SLIDING GATE. | | | 2. PLEASE PROVIDE TWO (2) COPIES OF A CURRENT / | | | ACCURATE SURVEY. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1448 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.WPB.ORG | | | | | 2013-03-14 14:10:23 | 3/14/13 |
|
|