Plan Review Details - Permit 13030118
Plan Review Stops For Permit 13030118
Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2013-03-29 Cont ID  
Sent By Mgonzale Date 2013-03-29 Time   Rev Time 1.00
Received By mgonzale Date 2013-03-29 Time   Sent To I
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2013-03-25 Cont ID  
Sent By mgonzale Date 2013-03-25 Time 13:42 Rev Time 0.00
Received By mgonzale Date 2013-03-25 Time 13:42 Sent To FIRE
Notes
2013-03-25 13:42:50PLEASE ADDRESS FIRE DEPT COMMENTS.
  
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2013-03-27 Cont ID  
Sent By wjolin Date 2013-03-27 Time 15:03 Rev Time 0.00
Received By wjolin Date 2013-03-27 Time 15:02 Sent To M
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2013-03-07 Cont ID  
Sent By mgonzale Date 2013-03-25 Time 13:43 Rev Time 0.00
Received By wjolin Date 2013-03-07 Time 12:16 Sent To ENG
Notes
2013-03-07 12:25:342275 PALM BEACH LAKES BOULEVARD
 PERMIT #13030118
 MASTER #12030334
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 NO ADDRESS PROVIDED IN THE PLAN TITLEBLOCK INFORMATION.
  
 PROVIDE CHAIN WITH LOCK AND TAMPER SWITCHES FOR
 SUPERVISING THE BACKFLOW PREVENTER IN THE OPEN
 POSITION.
  
 PER NFPA 24 (2010 ED) SECTION 7.2.3 FIRE HYDRANTS SHALL
 BE LOCATED NOT LESS THAN 40 FEET FROM THE BUILDING
 BEING PROTECTED.
  
 PER NFPA 24 (2010 ED) SECTION 5.2.1 PIPE SMALLER THAN
 6-INCHES IN DIAMETER SHALL NOT BE INSTALLED AS A
 PRIVATE SERVICE MAIN SUPPLYING FIRE HYDRANTS.
  
 NOTE: FIRE HYDRANTS SHALL BE PROVIDED WITH CLEARANCES
 OF 7?-6? TO THE FRONT AND SIDES AND 4? TO THE BACKSIDE
 PER SECTION 18.3.4.1 OF NFPA 1 FLORIDA EDITION. PARKING
 STALLS LOCATED WITHIN THIS CLEARANCE ZONE SHALL BE
 INDICATED WITH "NO PARKING BY ORDER OF THE FIRE
 MARSHAL" (OR SIMILAR).
  
 WESLEY JOLIN
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-04-01 Cont ID  
Sent By shill Date 2013-03-29 Time 09:46 Rev Time 0.00
Received By lmartine Date 2013-03-27 Time 09:46 Sent To  
Notes
2013-03-29 15:33:263/29 ON LM DESK
 ORIGINAL PLAN NOT ROUTED WITH RESUB SO OLD SHEETS NOT
 STAMPED; NEED TO SWAP SHEETS AND VERIFY THAT ORIGINAL
 SHEETS DO NOT NEED TO BE REVIEWED AND STAMPED BY
 ORIGINAL REVIEWERS
 PUT RESUB W/ORIGINAL PLAN ON LM DESK
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-03-26 Cont ID  
Sent By lmartine Date 2013-03-26 Time 12:32 Rev Time 0.00
Received By lmartine Date 2013-03-05 Time 14:06 Sent To  
Notes
2013-03-05 14:06:59TO FIRE
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2013-03-28 Cont ID  
Sent By hmoser Date 2013-03-28 Time 13:31 Rev Time 0.00
Received By hmoser Date 2013-03-28 Time 13:26 Sent To ENG
Notes
***NONE***